Comparison of HbA1c detection in whole blood and dried blood spots using an automated ion-exchange HPLC system

被引:18
|
作者
Maleska, Aleksandra [1 ,2 ,3 ]
Hirtz, Christophe [1 ]
Casteleyn, Elise [1 ]
Villard, Orianne [4 ]
Ducos, Jacques [2 ,3 ]
Avignon, Antoine [4 ]
Sultan, Ariane [4 ]
Lehmann, Sylvain [1 ]
机构
[1] Univ Montpellier, CHU Montpellier, INSERM U1183, Lab Biochim Proteom Clin, F-34000 Montpellier, France
[2] CHU Montpellier, Hop Lapeyronie, Lab Virol, F-34000 Montpellier, France
[3] INSERM, U1058, F-34000 Montpellier, France
[4] Univ Montpellier, Univ Hosp, CNRS UMR 9214, PhyMedExp,INSERM U1046,Endocrinol Diabetol Nutr D, Montpellier, France
关键词
clinical biology; DBS; dried blood spot; glycated hemoglobin; HbA1c; HPLC; ion exchange; ISO15189; method validation; DIABETES CONTROL; COMPLICATIONS TRIAL/EPIDEMIOLOGY; HEMOGLOBIN A1C; FILTER-PAPER; INTERVENTIONS; OUTCOMES; GLUCOSE; PATIENT; HBA(1C); SAMPLES;
D O I
10.4155/bio-2016-0278
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aim: Hemoglobin A1c (HbA1c) is a widely recognized analyte for diagnosing and monitoring diabetes. Dried blood spot (DBS) constitutes a useful alternative to blood collection by venipuncture. Analytical and clinical validation of DBS use is, however, necessary before implementation. Results/methodology: HbA1c levels from whole blood or DBS from a cohort patients with diabetes were compared. DBS specimens were stable at ambient temperature. HbA1c detection on DBS was accurate, robust, and the correlation and agreement with whole blood values was excellent. Conclusion: This study provides for the first time a complete method comparison and validation under the ISO15189 guideline using an automated HPLC system. This approach constitutes, therefore, a useful tool for diagnosing diabetes.
引用
收藏
页码:427 / 434
页数:8
相关论文
共 50 条
  • [1] Dried blood spots and HbA1c
    Holt, R. I. G.
    DIABETIC MEDICINE, 2020, 37 (09) : 1417 - 1417
  • [2] Evaluation of an Ion-Exchange HPLC Device for HbA1c Measurement
    Altawallbeh, Ghaith
    Makky, Vicky F.
    Saenger, Amy K.
    Peters, Jennifer M.
    Killeen, Anthony A.
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2020, 5 (04): : 695 - 703
  • [3] HbA1c measurements from dried blood spots: validation and patient satisfaction
    Fokkema, M. Rebecca
    Bakker, Andries J.
    de Boer, Fokje
    Kooistra, Jeltsje
    de Vries, Sifra
    Wolthuis, Albert
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (10) : 1259 - 1264
  • [4] STABILITY OF HBA1C BY ION-EXCHANGE, AFFINITY, HPLC AND ISOELECTRIC-FOCUSING
    MULLINS, RE
    PAPADEA, C
    AUSTIN, GE
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1230 - 1230
  • [5] Comment on HbA1c determination from HemaSpot blood collection devices: comparison of home-prepared dried blood spots with standard venous blood analysis
    Verougstraete, N.
    Stove, V.
    Stove, C.
    DIABETIC MEDICINE, 2020, 37 (09) : 1613 - 1614
  • [6] Capillary blood HbA1c measurement by HPLC.
    Arribas, I
    Ruiz-Alvarez, MJ
    Franco, P
    Gómez-Sereno, B
    Gaspar, MJ
    Varela, LA
    Ramírez, J
    Coca, MC
    CLINICAL CHEMISTRY, 2003, 49 (06) : A129 - A129
  • [7] Harmonisation of HbA1c in Sweden using mono S ion-exchange chromatography
    Larsson, B
    Malm, J
    Nordin, G
    Jeppsson, JO
    CLINICA CHIMICA ACTA, 2005, 355 : S414 - S414
  • [8] Evaluation of two methods to whole blood HbA1c
    Wang, J. Z.
    Jiang, H.
    Tian, Y. P.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A211 - A212
  • [9] Preliminary comparative study of HBA1c measurement by IEX-HPLC Bio-Rad in dried blood spot vs. whole venous blood
    Hadami, Khaoula
    Bennai, Redouane Mammar
    Touyar, Nora
    Amar, Lahcen
    Harisoa, Yasminah Josephine
    Kabbaj, Hakima
    Benouda, Amina
    Belefquih, Bouchra
    ANNALES DE BIOLOGIE CLINIQUE, 2025, 83 (-1) : 61 - 71
  • [10] HPLC analysis of HbA1c in dried blood spot samples (DBS): a reliable future for diabetes monitoring
    Lomeo, Angelo
    Bolner, Andrea
    Scattolo, Novella
    Guzzo, Patrizia
    Amadori, Franco
    Sartoroi, Samantha
    Lomeo, Luca
    CLINICAL LABORATORY, 2008, 54 (5-6) : 161 - 167