Numerical Simulation Study on Location Optimization of Indoor Air Purifiers in Bedroom

被引:6
|
作者
Yu Shui [1 ]
Ma Yuanliang [1 ]
Zhang Guojuan [1 ]
Wang Wei [1 ]
Feng Guohui [1 ]
机构
[1] Shenyang Jianzhu Univ, Sch Municipal & Environm Engn, Shenyang 110168, Liaoning, Peoples R China
基金
中国博士后科学基金;
关键词
Indoor air quality; Numerical simulation; Purifier;
D O I
10.1016/j.proeng.2017.10.024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Appropriate location for installing purifier in the bedroom can improve the air quality inside the bedroom. With standard k-epsilon turbulence model, this paper made the numerical simulation analysis of pollutant concentration distribution after installation of indoor air purification device, and found the best place to put purifier. Numerical simulation results show that formaldehyde concentration is low in the place of strength turbulence intensity and the place of outlet. When purification device is located in the opposite of bed, purification effect is the best, and purification speed also the fastest. (c) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:849 / 855
页数:7
相关论文
共 50 条
  • [1] Rating of mobile indoor air purifiers
    Finger, H.
    Schneiderwind, U.
    Asbach, C.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2015, 75 (11-12): : 497 - 502
  • [2] Optimizing indoor air quality and noise levels in old school classrooms with air purifiers and HRV: A CONTAM simulation study
    Na, Hooseung
    Choi, Haneul
    Kim, Haseong
    Park, Dongjun
    Lee, Joosang
    Kim, Taeyeon
    JOURNAL OF BUILDING ENGINEERING, 2023, 73
  • [3] Optimization of ventilation of an indoor ice rink by numerical simulation of air flows
    Starkova, L. G.
    Doroshenko, E. K.
    Zotova, D. A.
    INTERNATIONAL CONFERENCE ON CONSTRUCTION, ARCHITECTURE AND TECHNOSPHERE SAFETY (ICCATS 2020), 2020, 962
  • [4] Effects of Indoor Air Purifiers on Children with Asthma
    Lee, Ga Hee
    Kim, Jeong Hee
    Kim, Sungroul
    Lee, Sangwoon
    Lim, Dae Hyun
    YONSEI MEDICAL JOURNAL, 2020, 61 (04) : 310 - 316
  • [6] Reducing indoor particle exposure using mobile air purifiers-Experimental and numerical analysis
    Tobisch, Adrian
    Springsklee, Lukas
    Schaefer, Lisa-Franziska
    Sussmann, Nico
    Lehmann, Martin J.
    Weis, Frederik
    Zoellner, Raoul
    Niessner, Jennifer
    AIP ADVANCES, 2021, 11 (12)
  • [7] Experimental Study on Optimal Clean Air Delivery Rate Filter Thickness of Indoor Air Purifiers
    Lin, Cindy
    Kuo, Yu-Mei
    Lin, Maxie
    Lin, Jason
    Tsai, Pei-Yao
    Lin, Chih-Wei
    Huang, Sheng-Hsiu
    Chen, Chih-Chieh
    AEROSOL AND AIR QUALITY RESEARCH, 2024, 24 (12)
  • [8] Optimization of Operations of Air Purifiers for Control of Indoor PM2.5 Using BIM and CFD
    Chen, Keyu
    Tan, Zongneng
    Zhou, Huadong
    Tan, Yi
    BUILDINGS, 2023, 13 (01)
  • [9] Reducing indoor virus transmission using air purifiers
    Dbouk, Talib
    Roger, Frederic
    Drikakis, Dimitris
    PHYSICS OF FLUIDS, 2021, 33 (10)
  • [10] Direct numerical simulation of indoor air flow
    Sun, Zai
    Huang, Zhen
    Wang, Jia-Song
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2007, 41 (05): : 677 - 680