Experimental and numerical study of a mechanically ventilated enclosure with thermal effects

被引:15
|
作者
Kuznik, Frederic
Rusaouën, Gilles
Hohota, Raluca
机构
[1] Inst Natl Sci Appl, Thermal Sci Ctr, France INSA, F-69621 Villeurbanne, France
[2] Tech Univ Civil Engn Bucharest, Bucharest 72302, Romania
关键词
LES model; k-epsilon model; archimede effect; 3D jet behavior; building room;
D O I
10.1016/j.enbuild.2005.08.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Full-scale experimental and computational fluid dynamics (CFD) methods are used to investigate the velocity and temperature fields in a mechanically ventilated enclosure. Detailed airflow characteristics were measured in three cases of ventilation air temperature: an isothermal case, a hot case and a cold case. The experimental data were used to validate two CFD models: a Reynolds averaged Navier-Stokes equation (RANS) modelling and a large Eddy simulation (LES) modelling. The RANS model provides results in better agreement with experimental data, excepted for the cold case. It has been found that the LES model underestimates the expansion of the jet in the three cases, disabling the use of this model for the prediction of the flow field in ventilated rooms. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:931 / 938
页数:8
相关论文
共 50 条
  • [1] Experimental measurements and large eddy simulation of expiratory droplet dispersion in a mechanically ventilated enclosure with thermal effects
    Berrouk, Abdallah S.
    Lai, Alvin C. K.
    Cheung, Albert C. T.
    Wong, S. L.
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (02) : 371 - 379
  • [2] Experimental study of a travelling fire along a cable tray assembly in a mechanically ventilated enclosure
    Seguillon, Jeremy
    Pretrel, Hugues
    Suard, Sylvain
    [J]. FIRE SAFETY JOURNAL, 2023, 141
  • [3] Experimental and numerical investigation of mechanically ventilated rooms
    Teodosiu, Raluca
    David, Damien
    Teodosiu, Catalin
    Rusaouen, Gilles
    Ilie, Viorel
    Chi-Kien Nguyen
    [J]. SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 252 - 260
  • [4] Numerical study of forced ventilated fire in enclosure
    Liu, YL
    Moser, A
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 243 - 250
  • [5] Numerical and experimental study of velocity and temperature characteristics in a ventilated enclosure with underfloor ventilation systems
    Wan, MP
    Chao, CY
    [J]. INDOOR AIR, 2005, 15 (05) : 342 - 355
  • [6] Experimental and numerical study of a mechanically ventilated glass double facade with integrated shading device
    Manz, H
    Simmler, H
    [J]. RESEARCH IN BUILDING PHYSICS, 2003, : 519 - 526
  • [7] Experimental and numerical study of an elevated pool fire scenario in a confined and mechanically ventilated compartment
    Vaux, Samuel
    Georges, Emeline
    Pretrel, Hugues
    [J]. FIRE SAFETY JOURNAL, 2024, 142
  • [8] Experimental and Numerical Simulation Study on Multilayer Cable Trays Fire Under Mechanically Ventilated Conditions
    Huang, Xianjia
    Wu, Tianqi
    Bi, Kun
    Liu, Xiaoshuang
    Jiang, Xi
    [J]. PROCEEDINGS OF THE 20TH PACIFIC BASIN NUCLEAR CONFERENCE, VOL 1, 2017, : 317 - 325
  • [9] Experimental and numerical study of water spray system for a fire event in a confined and mechanically ventilated compartment
    Vaux, Samuel
    Pretrel, Hugues
    Audouin, Laurent
    [J]. FIRE AND MATERIALS, 2019, 43 (05) : 579 - 590
  • [10] Experimental and numerical study of a full scale ventilated enclosure:: Comparison of four two equations closure turbulence models
    Kuznik, Frederic
    Rusaouen, Gilles
    Brau, Jean
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1043 - 1053