Reduction of gradient acoustic noise in MRI using SENSE-EPI

被引:48
|
作者
de Zwart, JA
van Gelderen, P
Kellman, P
Duyn, JH
机构
[1] NINDS, Lab Funct & Mol Imaging, NIH, Bethesda, MD 20892 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1006/nimg.2002.1119
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A new approach to reduce gradient acoustic noise levels in EPI experiments is presented. Using multichannel RF receive coils, combined. With SENSE data Acquisition and reconstruction, gradient slew-rates in single-shot EPI were reduced fourfold for rate-2 and ninefold for rate-3 SENSE. Multislice EPI experiments Were performed on three different scanner platforms. With 3.4 min in-plane resolution, measuring 6 slices per second (1 slices with 2000 ms TR), this resulted in average sound pressure level reductions of 11.3 dB(A) and 16.5 dB(A) for rate-2 and rate-3 SENSE, respectively. BOLD fMRI experiments, using visually paced finger-tapping paradigms, showed no detrimental effect of the acoustic noise reduction strategy con temporal noise levels and t scores.
引用
收藏
页码:1151 / 1155
页数:5
相关论文
共 50 条
  • [1] Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI)
    Preibisch, C
    Pilatus, U
    Bunke, R
    Hoogenraad, F
    Zanella, F
    Lanfermann, H
    NEUROIMAGE, 2003, 19 (02) : 412 - 421
  • [2] Diffusion tensor imaging using single-shot SENSE-EPI
    Bammer, R
    Auer, M
    Keeling, SL
    Augustin, M
    Stables, LA
    Prokesch, RW
    Stollberger, R
    Moseley, ME
    Fazekas, F
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 128 - 136
  • [3] Acoustic noise reduction for spiral MRI by gradient derating
    Zhou, Zeyu
    Alfayad, Abdulrahman
    Chao, Tzu Cheng
    Pipe, James G.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (04) : 1547 - 1554
  • [4] Active-passive gradient shielding for MRI acoustic noise reduction
    Edelstein, WA
    Kidane, TK
    Taracila, V
    Baig, TN
    Eagan, TP
    Cheng, YCN
    Brown, RW
    Mallick, JA
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) : 1013 - 1017
  • [5] Comparison of Spiral Imaging and SENSE-EPI at 1.5 and 3.0 T Using a Controlled Cerebrovascular Challenge
    Winter, Jeff D.
    Poublanc, Julien
    Crawley, Adrian P.
    Kassner, Andrea
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (05) : 1206 - 1210
  • [6] Acoustic noise reduction in MRI using Silent Scan: an initial experience
    Alibek, Sedat
    Vogel, Mika
    Sun, Wei
    Winkler, David
    Baker, Christopher A.
    Burke, Michael
    Gloger, Hubertus
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (04) : 360 - 363
  • [7] Quiet MRI with novel acoustic noise reduction
    Katsunuma, A
    Takamori, H
    Sakakura, Y
    Hamamura, Y
    Ogo, Y
    Katayama, R
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 13 (03): : 139 - 144
  • [8] A Review on Evolution of Acoustic Noise Reduction in MRI
    Takkar, Manpreet Singh
    Sharma, Manoj Kumar
    Pal, Ravi
    2017 RECENT DEVELOPMENTS IN CONTROL, AUTOMATION AND POWER ENGINEERING (RDCAPE), 2017, : 235 - 240
  • [9] Quiet MRI with novel acoustic noise reduction
    A. Katsunuma
    H. Takamori
    Y. Sakakura
    Y. Hamamura
    Y. Ogo
    R. Katayama
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2001, 13 (3) : 139 - 144
  • [10] Tikhonov Regularization Approach for Acoustic Noise Reduction in an Asymmetric, Self-Shielded MRI Gradient Coil
    Jackson, James M.
    Brideson, Michael A.
    Forbes, Larry K.
    Crozier, Stuart
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2010, 37B (03) : 167 - 179