Evaluation of the Hemodynamic Effects of AC Magnetic Field Exposure by Measurement of an FMD and a Microscope

被引:4
|
作者
Kondo, Tsukasa [1 ]
Okano, Hideyuki [2 ]
Ishiwatari, Hiromi [3 ]
Watanuki, Keiichi [1 ,2 ,4 ]
机构
[1] Saitama Univ, Grad Sch Sci & Engn, Saitama, Japan
[2] Saitama Univ, Adv Inst Innovat Technol, Saitama, Japan
[3] Soken Med Co Ltd, Tokyo, Japan
[4] Saitama Univ, Brain & Body Syst Sci Inst, Saitama, Japan
来源
ADVANCES IN HUMAN FACTORS AND ERGONOMICS IN HEALTHCARE AND MEDICAL DEVICES | 2019年 / 779卷
关键词
Electromagnetic field; Flow-Mediated Dilatation (FMD); Microcirculation; BLOOD-FLOW; NITRIC-OXIDE; STIMULATION; SYSTEM;
D O I
10.1007/978-3-319-94373-2_8
中图分类号
F [经济];
学科分类号
02 ;
摘要
This study focuses on the acute influence of an AC electromagnetic field (ELF-EMF) exposure (50 Hz, B-max 180 mT) on flow-mediated dilation (FMD) and peripheral capillary flow velocity in healthy human subjects. In a randomized, double blind and crossover design, the sham control (CTL) and the EMF exposures were carried out. For FMD study, exposure of the left upper arm to EMF was performed for 30 min in a supine position. In the case of the measurement of microcirculation, exposure of the left forearm to EMF was conducted for 15 min in a sitting position. The FMD values were significantly increased from the baseline value in the presence of EMF exposure. The values of the microcirculation were significantly increased by the EMF exposure. These results imply that the EMF-enhanced vasodilation and microcirculation might help eliminate the metabolic waste products and endogenous pain producing substances inducing muscle stiffness and pain.
引用
收藏
页码:68 / 79
页数:12
相关论文
共 50 条
  • [1] From the magnetic field measurement to the numerical evaluation of the human exposure
    Canova, Aldo
    Cirimele, Vincenzo
    Freschi, Fabio
    Giaccone, Luca
    2016 IEEE CONFERENCE ON ELECTROMAGNETIC FIELD COMPUTATION (CEFC), 2016,
  • [2] Evaluation of the Effects of Magnetic Field Exposure on Body Sway
    Yamaguchi-Sekino, Sachiko
    Iwakiri, Kazuyuki
    Sekino, Masaki
    Nakai, Toshiharu
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2022, 17 (07) : 981 - 985
  • [3] MEASUREMENT OF MAGNETIC CORE NOISE EXCITED BY AC FIELD
    SHIRAE, K
    ELECTRICAL ENGINEERING IN JAPAN, 1973, 92 (03) : 69 - 78
  • [4] AC MAGNETIC-FIELD MEASUREMENT USING THE FLUXGATE
    RIPKA, P
    PRIMDAHL, F
    NIELSEN, OV
    PETERSEN, JR
    RANTA, A
    SENSORS AND ACTUATORS A-PHYSICAL, 1995, 46 (1-3) : 307 - 311
  • [5] Effects of microscope objectives on magnetic field exposures
    Publicover, NG
    Marsh, CG
    Vincze, CA
    Craviso, GL
    Chatterjee, I
    BIOELECTROMAGNETICS, 1999, 20 (06) : 387 - 395
  • [6] Measurement of AC magnetic field distribution using magnetic resonance imaging
    Ider, YZ
    Muftuler, LT
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) : 617 - 622
  • [7] Field emission measurement and evaluation by field ion microscope of carbon nanotube
    Yoshimura, Toshihiko
    Inami, Kazunori
    Yamashita, Youji
    Shinku/Journal of the Vacuum Society of Japan, 2004, 47 (03) : 140 - 142
  • [8] Measurement of the effects of the localized field of a magnetic force microscope tip on a 180 degrees domain wall
    Foss, S
    Dahlberg, ED
    Proksch, R
    Moskowitz, BM
    JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) : 5032 - 5034
  • [9] APPLICATION OF AC MAGNETIC-FIELD COMPENSATION TO A SCANNING ELECTRON-MICROSCOPE
    GEMPERLE, A
    NOVAK, J
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1976, 9 (06): : 490 - 495
  • [10] AC magnetic field measurement of CSNS/RCS quadrupole prototype
    Zhou, J. X.
    Li, L.
    Yin, B. G.
    Deng, C. D.
    Kang, W.
    Fu, S. N.