A PVC-graphite composite electrode for electroanalytical use. Preparation and some applications

被引:51
|
作者
Albertus, F
Llerena, A
Alpizar, J
Cerda, V
Luque, M
Rios, A
Valcarcel, M
机构
[1] UNIV CORDOBA,FAC SCI,DEPT ANALYT CHEM,E-14004 CORDOBA,SPAIN
[2] UNIV HAVANA,FAC CHEM,DEPT ANALYT CHEM,HAVANA 10400,CUBA
[3] UNIV ILLES BALEARS,DEPT CHEM,PALMA DE MALLORCA,SPAIN
关键词
composite electrode; PVC-graphite; voltammetry; stripping; flow amperometric detection;
D O I
10.1016/S0003-2670(97)81608-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation of a new carbon composite electrode, constructed from PVC-graphite compressed mixtures, is described. The performance as a working electrode for oxidative voltammetry was studied with cyclic voltammetry on hexacyanoferrate(III) in 1M HCl. Catechol and hydroquinone were also used as model test systems. Well defined current potential curves are reported. Examples of applications in anodic stripping voltammetry (ASV), including the formation of mercury films are presented. The possible use of PVC-graphite electrodes placed in a typical wall-jet flow cell as amperometric detectors was also examined by employing catechol as the test analyte. The PVC-graphite composite exhibits favorable qualities as an electrode material, with respect to its mechanical resistance, very low cost, simple preparation and easy renewal of the electrode surface. The results show a satisfactory combination of good electrode kinetics, with small background current, and relatively reproducible signals. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 50 条
  • [1] A PVC-graphite composite electrode for electroanalytical use. Preparation and some applications
    Albertus, F.
    Llerena, A.
    Alpizar, J.
    Cerda, V.
    Analytica Chimica Acta, 355 (01):
  • [2] Validation of PVC-graphite composite electrodes for routine analytical work
    Luque, M
    Ríos, A
    Valcárcel, M
    ELECTROANALYSIS, 1999, 11 (15) : 1116 - 1123
  • [3] PREPARATION OF A POLYPYRROLE LEAD DIOXIDE COMPOSITE ELECTRODE FOR ELECTROANALYTICAL APPLICATIONS
    VELAYUTHAM, D
    NOEL, M
    TALANTA, 1992, 39 (05) : 481 - 486
  • [4] Screening of polyphenols in grape marc by online supercritical fluid extraction -: Amperometric detection with a PVC-graphite composite electrode
    Palenzuela, B
    Rodriguez-Amaro, R
    Ríos, A
    Valcárcel, M
    ELECTROANALYSIS, 2002, 14 (19-20) : 1427 - 1432
  • [5] STUDIES ON PREPARATION AND ELECTROANALYTICAL APPLICATIONS OF CU-PTFE COMPOSITE ELECTRODE
    XU, HD
    ZOU, MZ
    CAO, ZS
    PAN, SH
    YANG, HQ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1995, 16 (01): : 50 - 54
  • [7] Use of graphite polyurethane composite electrode for imipramine oxidation -: Mechanism proposal and electroanalytical determination
    de Toledo, RA
    Santos, MC
    Honório, KM
    da Silva, ABF
    Cavalheiro, ETG
    Mazo, LH
    ANALYTICAL LETTERS, 2006, 39 (03) : 507 - 520
  • [8] Electroanalytical Determination of Imipramine in Reconstituted Serum with a Graphite-Polyurethane Composite Electrode
    de Toledo, R. A.
    Santos, M. C.
    Shim, H.
    Mazo, L. H.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (09): : 6975 - 6985
  • [9] Use of a graphite-polyurethane composite electrode for electroanalytical determination of indole-3-acetic acid in soil samples
    de Toledo, R. A.
    Vaz, C. M. P.
    MICROCHEMICAL JOURNAL, 2007, 86 (02) : 161 - 165
  • [10] Graphite-Polyurethane Composite Electrode for the Electroanalytical Determination of Herbicide Diuron in Soil Solutions
    Soares, Gabriela Byzynski
    Lopes da Silva, Wilson Tadeu
    Pedro Vaz, Carlos Manoel
    SENSOR LETTERS, 2011, 9 (05) : 1786 - 1793