Sample pooling is a viable strategy for SARS-CoV-2 detection in low-prevalence settings

被引:32
|
作者
Chong, Brian S. W. [1 ]
Tran, Thomas [1 ]
Druce, Julian [1 ]
Ballard, Susan A. [2 ]
Simpson, Julie A. [3 ]
Catton, Mike [1 ]
机构
[1] Melbourne Hlth Peter Doherty Inst Infect & Immun, Victorian Infect Dis Reference Lab, Melbourne, Vic, Australia
[2] Univ Melbourne, Microbiol Diagnost Unit, Peter Doherty Inst Infect & Immun, Publ Hlth Lab, Melbourne, Vic, Australia
[3] Univ Melbourne, Ctr Epidemiol & Biostat, Melbourne Sch Populat & Global Hlth, Melbourne, Vic, Australia
关键词
SARS-CoV-2; COVID-19; pooling; polymerase chain reaction; IMMUNODEFICIENCY-VIRUS TYPE-1;
D O I
10.1016/j.pathol.2020.09.005
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has significantly increased demand on laboratory throughput and reagents for nucleic acid extraction and polymerase chain reaction (PCR). Reagent shortages may limit the expansion of testing required to scale back containment measures. The aims of this study were to investigate the viability of sample pooling as a strategy for increasing test throughput and conserving PCR reagents; and to report our early experience with pooling of clinical samples. A pre-implementation study was performed to assess the sensitivity and theoretical efficiency of two, four, and eight-sample pools in a real-time reverse transcription PCR-based workflow. A standard operating procedure was developed and implemented in two laboratories during periods of peak demand, inclusive of over 29,000 clinical samples processed in our laboratory. Sensitivity decreased (mean absolute increase in cycle threshold value of 0.6, 2.3, and 3.0 for pools of two, four, and eight samples, respectively) and efficiency increased as pool size increased. Gains from pooling diminished at high disease prevalence. Our standard operating procedure was successfully implemented across two laboratories. Increased workflow complexity imparts a higher risk of errors, and requires risk mitigation strategies. Turnaround time for individual samples increased, hence urgent samples should not be pooled. Pooling is a viable strategy for high-throughput testing of SARS-CoV-2 in low-prevalence settings.
引用
收藏
页码:796 / 800
页数:5
相关论文
共 50 条
  • [1] Pooled Sampling is an Efficient and Economical Strategy for SARS-CoV-2 Detection in Low-Prevalence Areas
    Sun, Xiang
    Deng, Li
    Zhan, Xuan
    Chen, Xiaojing
    Yang, Xiaohui
    Huang, Yingfeng
    Chen, XinChun
    Zheng, Weidong
    [J]. CLINICAL LABORATORY, 2022, 68 (05) : 2390 - 2395
  • [2] Pooled Sampling is an Efficient and Economical Strategy for SARS-CoV-2 Detection in Low-Prevalence Areas
    Sun, Xiang
    Deng, Li
    Zhan, Xuan
    Chen, Xiaojing
    Yang, Xiaohui
    Huang, Yingfeng
    Chen, XinChun
    Zheng, Weidong
    [J]. CLINICAL LABORATORY, 2021,
  • [3] Saliva sample pooling for the detection of SARS-CoV-2
    Pasomsub, Ekawat
    Watcharananan, Siriorn P.
    Watthanachockchai, Treewat
    Rakmanee, Kingkan
    Tassaneetrithep, Boonrat
    Kiertiburanakul, Sasisopin
    Phuphuakrat, Angsana
    [J]. JOURNAL OF MEDICAL VIROLOGY, 2021, 93 (03) : 1506 - 1511
  • [4] Sample pooling strategies for SARS-CoV-2 detection
    Lagopati, Nefeli
    Tsioli, Panagiota
    Mourkioti, Ioanna
    Polyzou, Aikaterini
    Papaspyropoulos, Angelos
    Zafiropoulos, Alexandros
    Evangelou, Konstantinos
    Sourvinos, George
    Gorgoulis, Vassilis G.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2021, 289
  • [5] Sample pooling as a strategy for community monitoring for SARS-CoV-2
    Sawicki, Rafal
    Korona-Glowniak, Izabela
    Boguszewska, Anastazja
    Stec, Agnieszka
    Polz-Dacewicz, Malgorzata
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] Sample pooling as a strategy for community monitoring for SARS-CoV-2
    Rafal Sawicki
    Izabela Korona-Glowniak
    Anastazja Boguszewska
    Agnieszka Stec
    Malgorzata Polz-Dacewicz
    [J]. Scientific Reports, 11
  • [7] Sample Pooling as a Strategy to Detect Community Transmission of SARS-CoV-2
    Hogan, Catherine A.
    Sahoo, Malaya K.
    Pinsky, Benjamin A.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2020, 323 (19): : 1967 - 1969
  • [8] Novel pooling strategy with sample concentration for screening of SARS-CoV-2
    Wang, Xueliang
    Huang, Zhongqiang
    Song, Jian
    Zhao, Ran
    Xiao, Yanqun
    Wang, Hualiang
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2022, 75 (09) : 646 - 648
  • [9] Evaluation of Sample Pooling for the Detection of SARS-CoV-2 RNA Using the Cobas SARS-CoV-2 Test
    McMillen, T.
    Jani, K.
    Babady, E.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2020, 22 (11): : S38 - S38
  • [10] Diagnostic performance of RT-PCR-based sample pooling strategy for the detection of SARS-CoV-2
    Hueda-Zavaleta, Miguel
    Copaja-Corzo, Cesar
    Benites-Zapata, Vicente A.
    Cardenas-Rueda, Pedro
    Maguina, Jorge L.
    Rodriguez-Morales, Alfonso J.
    [J]. ANNALS OF CLINICAL MICROBIOLOGY AND ANTIMICROBIALS, 2022, 21 (01)