CT-guided robotic needle biopsy of lung nodules with respiratory motion - experimental system and preliminary test

被引:39
|
作者
Zhou, Yu [1 ]
Thiruvalluvan, Kaarvannan [1 ]
Krzeminski, Lukasz [1 ]
Moore, William H. [2 ]
Xu, Zhigang [3 ]
Liang, Zhengrong [2 ]
机构
[1] SUNY Stony Brook, Dept Mech Engn, Stony Brook, NY 11794 USA
[2] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[3] SUNY Stony Brook, Dept Radiat Oncol, Stony Brook, NY 11794 USA
关键词
robotic; biopsy; lung nodule; CT guidance; TUMOR TRACKING; ULTRASOUND GUIDANCE; ASPIRATION BIOPSY; INTERVENTIONS; THERAPY; MRI; LESIONS; PNEUMOTHORAX; INTEGRATION; CYBERKNIFE;
D O I
10.1002/rcs.1441
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundCT-guided needle biopsy of lung nodules requires breath holding during needle placement, and is thus inapplicable to patients with difficulty in holding breath. MethodsA robotic needle biopsy technique is introduced, adapting to the patient respiratory pattern and using a robot manipulator to drive the needle towards a moving lung nodule. Based on the nodule respiratory motion model, needle placement is planned to follow an optimal timing and path, and is triggered based on the respiratory phase tracking. An experimental system has been created to study robotic needle placement. ResultsPreliminary phantom tests were conducted based on three representative clinically-collected lung nodule motion paths, using an 18-gauge coaxial needle set. 300 needle paths were implemented. Robotic needle driving was accomplished within 0.4s (a typical respiratory phase), and resulted in a needle placement accuracy of 0.5mm with a standard deviation about 0.1mm over the non-resistance paths. ConclusionThe proposed robotic needle placement technique is promising for accurately biopsying lung nodules under respiratory motion and those with very small sizes. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:317 / 330
页数:14
相关论文
共 50 条
  • [1] Effect of the respiratory motion of pulmonary nodules on CT-guided percutaneous transthoracic needle biopsy
    Kim, Dasom
    Han, Ji-Yeon
    Baek, Jin Wook
    Lee, Ho Young
    Cho, Hwa Jin
    Heo, Young Jin
    Shin, Gi Won
    ACTA RADIOLOGICA, 2023, 64 (07) : 2245 - 2252
  • [2] A CT-guided robotic needle puncture method for lung tumours with respiratory motion
    Wei, Lin
    Jiang, Shan
    Yang, Zhiyong
    Zhang, Guobin
    Ma, Liang
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 73 : 48 - 56
  • [3] CT-guided percutaneous needle biopsy of small lung nodules in children
    B. L. Connolly
    Peter G. Chait
    David S. Duncan
    Glenn Taylor
    Pediatric Radiology, 1999, 29 : 342 - 346
  • [4] Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules
    Tsukada, H
    Satou, T
    Iwashima, A
    Souma, T
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (01) : 239 - 243
  • [5] CT-guided percutaneous needle biopsy of small lung nodules in children
    Connolly, BL
    Chait, PG
    Duncan, DS
    Taylor, G
    PEDIATRIC RADIOLOGY, 1999, 29 (05) : 342 - 346
  • [6] CT-guided needle biopsy of small pulmonary nodules: Value of respiratory gating
    Tomiyama, N
    Mihara, N
    Maeda, M
    Johkoh, T
    Kozuka, T
    Honda, O
    Hamada, S
    Yoshida, S
    Nakamura, H
    RADIOLOGY, 2000, 217 (03) : 907 - 910
  • [7] DIAGNOSIS OF LUNG NODULES BY CT-GUIDED LUNG BIOPSY
    Song, Yong
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S129 - S129
  • [8] CT-guided needle biopsy of small pulmonary nodules: Value of respiratory gating device
    Tomiyama, N
    Mihara, N
    Maeda, H
    Johkoh, T
    Sogabe, M
    Nakamura, H
    RADIOLOGY, 1999, 213P : 385 - 385
  • [9] Pitfalls in CT-guided transthoracic needle biopsy of pulmonary nodules
    Yankelevitz, DF
    Davis, SD
    Chiarella, DA
    Henschke, CI
    RADIOGRAPHICS, 1996, 16 (05) : 1073 - 1084
  • [10] Effect of the respiratory motion of pulmonary nodules on CT-guided percutaneous transthoracic needle biopsy (dec, 10.1177/02841851231156905, 2022)
    Kim, D.
    Han, J-Y
    Baek, J. W.
    ACTA RADIOLOGICA, 2024, 65 (02) : 249 - 249