Management of entero-atmospheric fistulas by chyme reinfusion: A retrospective study

被引:8
|
作者
Layec, Sabrina [1 ]
Seynhaeve, Eloi [1 ]
Trivin, Florence [1 ]
Carsin-Mahe, Marie [1 ]
Dussaulx, Laurence [1 ]
Picot, Denis [1 ]
机构
[1] Clin St Yves, Nutr & Digest Rehabil Unit, Rennes, France
关键词
Chyme reinfusion; Entero-atmospheric fistula; Entero-cutaneous fistula; Intestinal failure; INTESTINAL FAILURE; SMALL-BOWEL; PARENTERAL-NUTRITION; FISTULOCLYSIS; ABSORPTION; SUPPORT;
D O I
10.1016/j.clnu.2020.03.030
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background & aims: High output entero-cutaneous fistulas may lead to intestinal failure with parenteral nutrition (PN) as the gold standard treatment to prevent dehydration and malnutrition. However in case of entero-atmospheric fistula (EAF) with the distal limb of the fistula accessible, chyme reinfusion (CR), a technique that restores artificially digestive continuity can be performed until the surgical repair. Our aim was to study the efficacy of CR in EAF regarding nutritional status, intestinal function, PN weaning and liver tests. Methods: Retrospective study of 37 patients admitted for EAF and treated by CR from 1993 to 2017. Delays were expressed in median (25%-75% quartiles) and other data on mean +/- SD. Results: Location of EAF: jejunum (29), ileum (8). The length of the upstream intestine was estimated in 21 patients: 19 had a bowel length <150 cm of which 16 had less than 100 cm. During CR, mean digestive losses decreased from 1734 +/- 578 to 443 +/- 487 ml/24 h (p < 0.000001), nitrogen absorption increased from 45.3 +/- 18.6 to 81.8 +/- 12.9% of ingesta (p < 0.001). The percentage of patients with plasma citrulline <20 mu mol/l decreased from 71 to 10%. PN was stopped in all patients within 3 (0-14) days after CR initiation, 2 patients required an intravenous hydration and 20 had an additional enteral support. The nutritional status improved: albumin (33.1 +/- 5.1 g/L vs 28.4 +/- 6.5, p < 0.001), NRI (decrease of the number of patients at risk of severe malnutrition from 22 to 10 (p < 0.001)). The number of patients who had one or several liver tests abnormalities (>2 N) decreased from 94 to 41% (p < 0.001). Conclusion: When the efferent part of the small bowel is accessible, CR is a safe and inexpensive method that restores bowel function. In most cases, it makes it possible to stop PN and helps to improve the nutritional status until surgical reconstruction. (C) 2020 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
引用
收藏
页码:3695 / 3702
页数:8
相关论文
共 50 条
  • [1] Entero-Cutaneous and Entero-Atmospheric Fistulas: Insights into Management Using Negative Pressure Wound Therapy
    Pepe, Gilda
    Chiarello, Maria Michela
    Bianchi, Valentina
    Fico, Valeria
    Altieri, Gaia
    Tedesco, Silvia
    Tropeano, Giuseppe
    Molica, Perla
    Di Grezia, Marta
    Brisinda, Giuseppe
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [2] ENTERO-ATMOSPHERIC FISTULA: THE EVOLUTION OF COMPLEX WOUND MANAGEMENT
    Makipour, John
    JOURNAL OF WOUND OSTOMY AND CONTINENCE NURSING, 2011, 38 (03) : S49 - S50
  • [3] A rare approach to entero-atmospheric fistula
    Meshikhes, Abdul-Wahed Nasir
    Al-Hariri, Abdulrazzak
    Al-Zahir, Ali Ahmed
    Al-Nahawi, Mamdouh
    AMERICAN JOURNAL OF CASE REPORTS, 2013, 14 : 476 - 480
  • [4] Novel chyme reinfusion device for gastrointestinal fistulas and stomas: feasibility study
    Sharma, P.
    Davidson, R.
    Davidson, J.
    Keane, C.
    Liu, C.
    Ritchie, S. R.
    Chu, K.
    Sutherland, G.
    Bissett, I. P.
    O'Grady, G.
    BRITISH JOURNAL OF SURGERY, 2020, 107 (09) : 1199 - 1210
  • [5] Effect of preoperative predigested formula vs. polymeric formula on bowel function recovery after definitive surgery for small intestinal entero-atmospheric fistula in patients with chyme reinfusion
    Tian, Weiliang
    Yao, Zheng
    Xu, Xin
    Luo, Shikun
    Zhao, Risheng
    FRONTIERS IN NUTRITION, 2022, 9
  • [6] Comment on: Novel chyme reinfusion device for gastrointestinal fistulas and stomas: feasibility study
    Somashekar, Uday
    Sharma, Dhananjaya
    BRITISH JOURNAL OF SURGERY, 2020, 107 (11) : E556 - E556
  • [7] Classification, prevention and management of entero-atmospheric fistula: a state-of-the-art review
    Di Saverio, Salomone
    Tarasconi, Antonio
    Walczak, Dominik A.
    Cirocchi, Roberto
    Mandrioli, Matteo
    Birindelli, Arianna
    Tugnoli, Gregorio
    LANGENBECKS ARCHIVES OF SURGERY, 2016, 401 (01) : 1 - 13
  • [8] Classification, prevention and management of entero-atmospheric fistula: a state-of-the-art review
    Salomone Di Saverio
    Antonio Tarasconi
    Dominik A. Walczak
    Roberto Cirocchi
    Matteo Mandrioli
    Arianna Birindelli
    Gregorio Tugnoli
    Langenbeck's Archives of Surgery, 2016, 401 : 1 - 13
  • [9] Author response to: Comment on: Novel chyme reinfusion device for gastrointestinal fistulas and stomas: feasibility study
    Bissett, I. P.
    Davidson, J.
    Sutherland, G.
    O'Grady, G.
    BRITISH JOURNAL OF SURGERY, 2020, 107 (11) : E557 - E557
  • [10] Using a bio-scanner and 3D printing to create an innovative custom made approach for the management of complex entero-atmospheric fistulas
    Duran Munoz-Cruzado, Virginia
    Calero Castro, Francisco Jose
    Padillo Eguia, Andres
    Tallon Aguilar, Luis
    Tinoco Gonzalez, Jose
    Puyana, Juan Carlos
    Pareja Ciuro, Felipe
    Padillo-Ruiz, Javier
    SCIENTIFIC REPORTS, 2020, 10 (01)