Letter regarding 'Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics' by Patrizi et al. and research reproducibility

被引:11
|
作者
Spector, June [1 ]
Lieblich, Max [2 ]
机构
[1] Univ Washington, Dept Environm & Occupat Hlth Sci, Seattle, WA 98195 USA
[2] Univ Washington, Dept Math, Seattle, WA 98195 USA
关键词
Ergonomics tools and methods; software design and evaluation; task analysis; musculoskeletal disorders;
D O I
10.1080/00140139.2015.1136700
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The reporting of research in a manner that allows reproduction in subsequent investigations is important for scientific progress. Several details of the recent study by Patrizi et al., Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics', are absent from the published manuscript and make reproduction of findings impossible. As new and complex technologies with great promise for ergonomics develop, new but surmountable challenges for reporting investigations using these technologies in a reproducible manner arise.Practitioner Summary: As with traditional methods, scientific reporting of new and complex ergonomics technologies should be performed in a manner that allows reproduction in subsequent investigations and supports scientific advancement.
引用
收藏
页码:597 / 598
页数:2
相关论文
共 4 条
  • [1] Letter regarding 'Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics' by Patrizi et al. and research reproducibility Response
    Patrizi, Alfredo
    Pennestri, Ettore
    Valentini, Pier Paolo
    [J]. ERGONOMICS, 2017, 60 (04) : 599 - 600
  • [2] Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics
    Patrizi, Alfredo
    Pennestri, Ettore
    Valentini, Pier Paolo
    [J]. ERGONOMICS, 2016, 59 (01) : 155 - 162
  • [3] COMPARISON OF MARKER-BASED AND MARKER-LESS SYSTEMS FOR LOW-COST HUMAN MOTION CAPTURE
    Puthenveetil, Sajeev C.
    Daphalapurkar, Chinmay P.
    Zhu, Wenjuan
    Leu, Ming C.
    Liu, Xiaoqing F.
    Chang, Alpha M.
    Gilpin-Mcminn, Julie K.
    Wu, Peter H.
    Snodgrass, Scott D.
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2013, VOL 2B, 2014,
  • [4] Comparison of marker-based and marker-less systems for low-cost human motion capture
    Puthenveetil, Sajeev C.
    Daphalapurkar, Chinmay P.
    Zhu, Wenjuan
    Leu, Ming C.
    Liu, Xiaoqing F.
    Chang, Alpha M.
    Gilpin-Mcminn, Julie K.
    Wu, Peter H.
    Snodgrass, Scott D.
    [J]. Proceedings of the ASME Design Engineering Technical Conference, 2013, 2 B