The effect of the skin-liver capsule distance on the accuracy of ultrasound diagnosis for liver steatosis and fibrosis

被引:4
|
作者
Uchikawa, Shinsuke [1 ]
Kawaoka, Tomokazu [1 ]
Fujino, Hatsue [1 ]
Ono, Atsushi [1 ]
Nakahara, Takashi [1 ]
Murakami, Eisuke [1 ]
Yamauchi, Masami [1 ]
Miki, Daiki [1 ]
Imamura, Michio [1 ]
Aikata, Hiroshi [1 ]
机构
[1] Hiroshima Univ, Inst Biomed & Hlth Sci, Dept Gastroenterol & Metab, Appl Life Sci, Hiroshima, Japan
关键词
Two-dimensional shear wave; FibroScan; Liver steatosis; Liver fibrosis; TRANSIENT ELASTOGRAPHY; XL PROBE; FEASIBILITY; PERFORMANCE; OVERWEIGHT;
D O I
10.1007/s10396-022-01210-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Transient elastography (TE) and the controlled attenuation parameter (CAP) have been used for diagnosis of liver fibrosis and steatosis. Obesity is a limiting factor to the accuracy of elastography; however, an XL probe was validated for use in obese patients. Two-dimensional shear wave elastography (2D-SWE) and attenuation imaging (ATI) have also been developed. It is unknown if obesity affects 2D-SWE/ATI values for evaluation of liver fibrosis and steatosis. We assessed the reliability of the measurement rate and the diagnostic performance of TE/CAP versus SWE/ATI. Methods The patients (n = 85) underwent TE/CAP, 2D-SWE/ATI, and liver biopsy on the same day. They were diagnosed with chronic hepatitis based on liver biopsy. The patients were divided into three groups by skin-liver capsule distance (SCD). Results The reliability of the measurement rate for the M probe was lower than that for the XL probe in the group with SCD over 22.5 mm. The rate achieved with 2D-SWE was high in all groups regardless of the SCD. In the assessment of the diagnostic performance, there was no difference between the area under the receiver-operating curve (AUROC) of TE compared to 2D-SWE to stratify the fibrosis stage. There was no difference in the AUROC for the stratification of the steatosis grades between CAP and ATI. The diagnostic accuracy of TE for F >= 3 fibrosis evaluated with the M probe and 2D-SWE was lower than that of TE evaluated with the XL probe in the group with SCD over 22.5 mm. Conclusion The ability of 2D-SWE to stratify fibrosis stage and steatosis grade was as good as FibroScan. However, 2D-SWE had a high reliability in the measurement rate regardless of the SCD with one probe. And the XL probe showed high diagnostic accuracy for severe fibrosis in the group with SCD over 22.5 mm.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 50 条
  • [1] The effect of the skin–liver capsule distance on the accuracy of ultrasound diagnosis for liver steatosis and fibrosis
    Shinsuke Uchikawa
    Tomokazu Kawaoka
    Hatsue Fujino
    Atsushi Ono
    Takashi Nakahara
    Eisuke Murakami
    Masami Yamauchi
    Daiki Miki
    Michio Imamura
    Hiroshi Aikata
    Journal of Medical Ultrasonics, 2022, 49 : 443 - 450
  • [2] Measurement of the Skin-Liver Capsule Distance on Ultrasound RF Data for 1D Transient Elastography
    Audiere, Stephane
    Charbit, Maurice
    Angelini, Elsa D.
    Oudry, Jennifer
    Sandrin, Laurent
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT II,, 2010, 6362 : 34 - +
  • [3] Ultrasound in the diagnosis of steatosis and fibrosis of chronic liver diseases
    Giorgio, A.
    DIGESTIVE AND LIVER DISEASE, 2007, 39 (04) : 391 - 392
  • [4] MEASUREMENT ACCURACY OF SKIN TO LIVER CAPSULE DISTANCE WITH VELACUR AND FIBROSCAN
    Curry, Michael P.
    Tam, Edward V.
    Abdelgelil, Noha
    Schneider, Caitlin
    Hassanein, Tarek I.
    Afdhal, Nezam H.
    HEPATOLOGY, 2021, 74 : 965A - 965A
  • [5] Ultrasound in the diagnosis of steatosis and fibrosis of chronic liver diseases - Reply
    de Sio, I.
    Palmentieri, B.
    Persico, M.
    DIGESTIVE AND LIVER DISEASE, 2007, 39 (04) : 392 - 392
  • [6] Prevalence of Liver Steatosis and Fibrosis and the Diagnostic Accuracy of Ultrasound in Bariatric Surgery Patients
    Jiang Wu
    Jing You
    Lisa Yerian
    Ayako Shiba
    Philip R. Schauer
    Daniel I. Sessler
    Obesity Surgery, 2012, 22 : 240 - 247
  • [7] Prevalence of Liver Steatosis and Fibrosis and the Diagnostic Accuracy of Ultrasound in Bariatric Surgery Patients
    Wu, Jiang
    You, Jing
    Yerian, Lisa
    Shiba, Ayako
    Schauer, Philip R.
    Sessler, Daniel I.
    OBESITY SURGERY, 2012, 22 (02) : 240 - 247
  • [8] Diagnosis of hepatic steatosis based on ultrasound attenuation imaging is not influenced by liver fibrosis
    Yuri, Minako
    Nishimura, Takashi
    Tada, Toshifumi
    Yoshida, Masahiro
    Fujiwara, Aoi
    Kawata, Shoki
    Yoshihara, Kohei
    Yoshioka, Ryota
    Ota, Shogo
    Nakano, Ryota
    Yuri, Yukihisa
    Takashima, Tomoyuki
    Aizawa, Nobuhiro
    Ikeda, Naoto
    Shiomi, Hideyuki
    Ide, Yoshi-Hiro
    Enomoto, Hirayuki
    Yasuhiro, Fujimoto
    Yano, Hirohisa
    Iijima, Hiroko
    HEPATOLOGY RESEARCH, 2022, 52 (12) : 1009 - 1019
  • [9] Liver ultrasound is not a good predictor of hepatic steatosis and fibrosis
    Jalil, Sajid
    Wood, Adam
    Frachtman, Steven
    Snyder, Ned
    Soloway, Roger
    Ernst, Randy
    Cesani, Fernando
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (09): : S170 - S170
  • [10] Ultrasound elastography in the diagnosis of liver fibrosis
    Zhu, Yingqiao
    Bai, Yang
    Wang, Dongxuan
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 : 168 - 168