The impact of using an intravenous workflow management system (IVWMS) on cost and patient safety

被引:8
|
作者
Lin, Alex C. [1 ]
Deng, Yihong [1 ]
Thaibah, Hilal [1 ]
Hingl, John [2 ]
Penm, Jonathan [3 ]
Ivey, Marianne F. [1 ]
Thomas, Mark [2 ]
机构
[1] Univ Cincinnati, James L Winkle Coll Pharm, Div Pharm Practice & Adm Sci, Cincinnati, OH 45229 USA
[2] Cincinnati Childrens Hosp Med Ctr, Dept Pharm, Cincinnati, OH 45229 USA
[3] Univ Sydney, Fac Pharm, Sydney, NSW, Australia
关键词
Pharmacy; Workflow management; Preparation error; Costs; Wasted missing doses; Operation;
D O I
10.1016/j.ijmedinf.2018.04.004
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Purpose: The aim of this study was to determine the financial costs associated with wasted and missing doses before and after the implementation of an intravenous workflow management system (IVWMS) and to quantify the number and the rate of detected intravenous (IV) preparation errors. Method: A retrospective analysis of the sample hospital information system database was conducted using three months of data before and after the implementation of an IVWMS System (DoseEdge (R)) which uses barcode scanning and photographic technologies to track and verify each step of the preparation process. The financial impact associated with wasted and missing> IV doses was determined by combining drug acquisition, labor, accessory, and disposal costs. The intercepted error reports and pharmacist detected error reports were drawn from the IVWMS to quantify the number of errors by defined error categories. Results: The total number of IV doses prepared before and after the implementation of the IVWMS system were 110,963 and 101,765 doses, respectively. The adoption of the IVWMS significantly reduced the amount of wasted and missing IV doses by 14,176 and 2268 doses, respectively (p < 0.001). The overall cost savings of using the system was $ 144,019 over 3 months. The total number of errors detected was 1160 (1.14%) after using the IVWMS. Conclusion: The implementation of the IVWMS facilitated workflow changes that led to a positive impact on cost and patient safety. The implementation of the IVWMS increased patient safety by enforcing standard operating procedures and bar code verifications.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [1] Optimising workflow using a workflow management system
    Vaandering, A.
    Coevoet, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S287 - S287
  • [2] A patient workflow management system built on guidelines
    Dazzi, L
    Fassino, C
    Saracco, R
    Quaglini, S
    Stefanelli, M
    [J]. JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1997, : 146 - 150
  • [3] Clinical Dashboards Impact on Workflow, Care Quality, and Patient Safety
    Egan, Marie
    [J]. CRITICAL CARE NURSING QUARTERLY, 2006, 29 (04) : 354 - 361
  • [4] Challenges in Measuring the Impact of Interruption on Patient Safety and Workflow Outcomes
    Magrabi, F.
    Li, S. Y. W.
    Dunn, A. G.
    Coeira, E.
    [J]. METHODS OF INFORMATION IN MEDICINE, 2011, 50 (05) : 447 - 453
  • [5] Impact of Cardiac Telemetry on Patient Safety and Cost
    Benjamin, Evan M.
    Klugman, Robert A.
    Luckmann, Roger
    Fairchild, David G.
    Abookire, Susan A.
    [J]. AMERICAN JOURNAL OF MANAGED CARE, 2013, 19 (06): : E225 - E232
  • [6] The impact of education background on using cost management system information
    Liem, Vo Tan
    [J]. COGENT BUSINESS & MANAGEMENT, 2021, 8 (01):
  • [7] Using a Low-Cost Simulation Approach for Assessing the Impact of a Medication Administration System on Workflow
    Kushniruk, A. W.
    Borycki, E. M.
    Kuwata, S.
    Watanabe, H.
    [J]. EHEALTH BEYOND THE HORIZON - GET IT THERE, 2008, 136 : 567 - +
  • [8] Workflow management system using mobile agents
    Budimac, Z
    Ivanovic, M
    Popovic, A
    [J]. ADVANCES IN DATABASES AND INFORMATION SYSTEMS, 1999, 1691 : 168 - 178
  • [9] Using a Uniform Petri Net for Safety Workflow Management Systems
    Cui, Luning
    Liu, Lingyan
    [J]. ISISE 2008: INTERNATIONAL SYMPOSIUM ON INFORMATION SCIENCE AND ENGINEERING, VOL 1, 2008, : 483 - +
  • [10] Implications of using AMSORB® Plus in clinical practice: cost, patient safety and environmental impact
    Jones, A.
    Dobson, A.
    [J]. ANAESTHESIA, 2020, 75 : 31 - 31