Evaluation of a 3D-printed total knee arthroplasty using radiostereometric analysis ASSESSMENT OF HIGHLY POROUS BIOLOGICAL FIXATION OF THE TIBIAL BASEPLATE AND METAL-BACKED PATELLAR COMPONENT

被引:40
|
作者
Sporer, S. [1 ,2 ]
MacLean, L. [1 ,3 ]
Burger, A. [1 ,3 ]
Moric, M. [1 ,4 ]
机构
[1] Northwestern Med Cent DuPage Hosp, Winfield, IL 60190 USA
[2] Rush Univ, Med Ctr, Orthopaed Surg, Chicago, IL 60612 USA
[3] Halifax Biomed Inc, Mabou, NS, Canada
[4] Rush Univ, Med Ctr, Dept Anesthesiol, Chicago, IL 60612 USA
来源
BONE & JOINT JOURNAL | 2019年 / 101B卷 / 07期
关键词
UNITED-STATES; LATE REVISION; MIGRATION; RSA; OSTEOARTHRITIS; METAANALYSIS; HIP;
D O I
10.1302/0301-620X.101B7.BJJ-2018-1466.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims Our intention was to investigate if the highly porous biological fixation surfaces of a new 3D-printed total knee arthroplasty (TKA) achieved adequate fixation of the tibial and patellar components to the underlying bone. Patients and Methods A total of 29 patients undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate and metal-backed patella. Patient-reported outcomes measures were recorded and implant migration was assessed using radiostereometric analysis. Results Patient function significantly improved by three months postoperatively (p < 0.001). Mean difference in maximum total point motion between 12 and 24 months was 0.021 mm (-0.265 to 0.572) for the tibial implant and 0.089 mm (-0.337 to 0.758) for the patellar implant. The rate of tibial and patellar migration was largest over the first six postoperative weeks, with no changes in mean tibia migration occurring after six months, and no changes in mean patellar migration occurring after six weeks. One patellar component showed a rapid rate of migration between 12 and 24 months. Conclusion Biological fixation appears to occur reliably on the highly porous implant surface of the tibial baseplate and metal-backed patellar component. Rapid migration after 12 months was measured for one patellar component. Further investigation is required to assess the long-term stability of the 3D-printed components and to determine if the high-migrating components achieve fixation.
引用
收藏
页码:40 / 47
页数:8
相关论文
共 9 条
  • [1] Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty -: Prospective, randomized radiostereometric analysis study of the AGC total knee prosthesis
    Adalberth, G
    Nilsson, KG
    Byström, S
    Kolstad, K
    Milbrink, J
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (06): : 783 - 792
  • [2] Tibial Component Fixation with a Peri-Apatite Coating Evaluation by Radiostereometric Analysis in a Canine Total Knee Arthroplasty Model
    Allen, Matthew J.
    Leone, Kendall A.
    Dunbar, Michael J.
    Race, Amos
    Rosenbaum, Paula F.
    Sacks, Jonathan M.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1138 - 1148
  • [3] A Meta-Analysis Comparing All-Polyethylene Tibial Component to Metal-Backed Tibial Component in Total Knee Arthroplasty: Assessing Survivorship and Functional Outcomes
    Voss, Benjamin
    El-Othmani, Mouhanad M.
    Schnur, Anne-Kathrin
    Botchway, Albert
    Mihalko, William M.
    Saleh, Khaled J.
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (11): : 2628 - 2636
  • [4] Tibial component fixation in porous- and hydroxyapatite-coated total knee arthroplasty -: A radiostereometric evaluation of migration and inducible displacement after 5 years
    Regnér, L
    Carlsson, L
    Kärrholm, J
    Herberts, P
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (06): : 681 - 689
  • [5] Migration of a novel 3D-printed cementless versus a cemented total knee arthroplasty: two-year results of a randomized controlled trial using radiostereometric analysis
    Hasan, S.
    van Hamersveld, K. T.
    Marang-van de Mheen, P. J.
    Kaptein, B. L.
    Nelissen, R. G. H. H.
    Toksvig-Larsen, S.
    [J]. BONE & JOINT JOURNAL, 2020, 102B (08): : 1016 - 1024
  • [6] Analysis of Tibial Component Rotation Following Total Knee Arthroplasty Using 3D High Definition Computed Tomography
    Roper, Glade E.
    Bloemke, Adam D.
    Roberts, Catherine C.
    Spangehl, Mark J.
    Clarke, Henry D.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 106 - 111
  • [7] Cementless 3D Printed Highly Porous Titanium-Coated Baseplate Total Knee Arthroplasty: Survivorship and Outcomes at 2-Year Minimum Follow-Up
    Sultan, Assem A.
    Mahmood, Bilal
    Samuel, Linsen T.
    Stearns, Kim L.
    Molloy, Robert M.
    Moskal, Joseph T.
    Krebs, Viktor E.
    Harwin, Steven F.
    Mont, Michael A.
    [J]. JOURNAL OF KNEE SURGERY, 2020, 33 (03) : 279 - 283
  • [8] All-polyethylene vs. metal-backed tibial component in total knee arthroplasty -: a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components -: Part 2.: Completely cemented components:: MB not superior to AP components
    Hyldahl, H
    Regnér, L
    Carlsson, L
    Kärrholm, J
    Weidenhielm, L
    [J]. ACTA ORTHOPAEDICA, 2005, 76 (06) : 778 - 784
  • [9] All-polyethylene vs. metal-backed tibial component in total knee arthroplasty -: a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components -: Part 1.: Horizontally cemented components:: AP better fixated than MB
    Hyldahl, H
    Regnér, L
    Carlsson, L
    Kärrholm, J
    Weidenhielm, L
    [J]. ACTA ORTHOPAEDICA, 2005, 76 (06) : 769 - 777