Mismatch Negativity (MMN) in Freely-Moving Rats with Several Experimental Controls

被引:66
|
作者
Harms, Lauren [1 ,2 ,3 ,4 ]
Fulham, W. Ross [1 ,2 ,3 ,4 ,5 ]
Todd, Juanita [1 ,2 ,3 ,4 ]
Budd, Timothy W. [1 ,2 ,3 ,4 ]
Hunter, Michael [1 ,2 ,4 ]
Meehan, Crystal [1 ,2 ,3 ]
Penttonen, Markku [6 ]
Schall, Ulrich [2 ,3 ,4 ,5 ]
Zavitsanou, Katerina [7 ,8 ]
Hodgson, Deborah M. [1 ,2 ,3 ,4 ]
Michie, Patricia T. [1 ,2 ,3 ,4 ]
机构
[1] Univ Newcastle, Sch Psychol, Callaghan, NSW 2308, Australia
[2] Univ Newcastle, Prior Ctr Translat Neuroscience & Mental Hlth Res, Newcastle, NSW 2300, Australia
[3] Schizophrenia Res Inst, Darlinghurst, NSW, Australia
[4] Hunter Med Res Inst, Newcastle, NSW, Australia
[5] Univ Newcastle, Sch Med & Publ Hlth, Callaghan, NSW 2308, Australia
[6] Univ Jyvaskyla, Dept Psychol, Jyvaskyla, Finland
[7] Univ New S Wales, Fac Med, Sch Psychiat, Sydney, NSW, Australia
[8] Neurosci Res Australia, Randwick, NSW, Australia
来源
PLOS ONE | 2014年 / 9卷 / 10期
基金
英国医学研究理事会;
关键词
STIMULUS-SPECIFIC ADAPTATION; EVENT-RELATED POTENTIALS; AUDITORY CHANGE-DETECTION; EVOKED-POTENTIALS; ANESTHETIZED RATS; CORTICAL-NEURONS; ANIMAL-MODELS; SOUND CHANGES; PITCH CHANGE; CORTEX;
D O I
10.1371/journal.pone.0110892
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Mismatch negativity (MMN) is a scalp-recorded electrical potential that occurs in humans in response to an auditory stimulus that defies previously established patterns of regularity. MMN amplitude is reduced in people with schizophrenia. In this study, we aimed to develop a robust and replicable rat model of MMN, as a platform for a more thorough understanding of the neurobiology underlying MMN. One of the major concerns for animal models of MMN is whether the rodent brain is capable of producing a human-like MMN, which is not a consequence of neural adaptation to repetitive stimuli. We therefore tested several methods that have been used to control for adaptation and differential exogenous responses to stimuli within the oddball paradigm. Epidural electroencephalographic electrodes were surgically implanted over different cortical locations in adult rats. Encephalographic data were recorded using wireless telemetry while the freely-moving rats were presented with auditory oddball stimuli to assess mismatch responses. Three control sequences were utilized: the flip-flop control was used to control for differential responses to the physical characteristics of standards and deviants; the many standards control was used to control for differential adaptation, as was the cascade control. Both adaptation and adaptation-independent deviance detection were observed for high frequency (pitch), but not low frequency deviants. In addition, the many standards control method was found to be the optimal method for observing both adaptation effects and adaptation-independent mismatch responses in rats. Inconclusive results arose from the cascade control design as it is not yet clear whether rats can encode the complex pattern present in the control sequence. These data contribute to a growing body of evidence supporting the hypothesis that rat brain is indeed capable of exhibiting human-like MMN, and that the rat model is a viable platform for the further investigation of the MMN and its associated neurobiology.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Development of a Visual Mismatch Negativity Task in Freely Moving Mice
    Kat, Renate
    Perenboom, M. J. L.
    Wams, E. J.
    Bruining, H.
    Tolner, E. A.
    Kas, M. J. H.
    [J]. NEUROPSYCHOBIOLOGY, 2018, 77 (03) : 133 - 133
  • [2] INTRAVENOUS MICRODIALYSIS SAMPLING IN AWAKE, FREELY-MOVING RATS
    TELTINGDIAZ, M
    SCOTT, DO
    LUNTE, CE
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (07) : 806 - 810
  • [3] Wireless inertial measurement of head kinematics in freely-moving rats
    Pasquet, Matthieu O.
    Tihy, Matthieu
    Gourgeon, Aurelie
    Pompili, Marco N.
    Godsil, Bill P.
    Lena, Clement
    Dugue, Guillaume P.
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [4] Wireless inertial measurement of head kinematics in freely-moving rats
    Matthieu O. Pasquet
    Matthieu Tihy
    Aurélie Gourgeon
    Marco N. Pompili
    Bill P. Godsil
    Clément Léna
    Guillaume P. Dugué
    [J]. Scientific Reports, 6
  • [5] Fast-scan cyclic voltammetry in freely-moving rats
    Phillips, PEM
    Budygin, EA
    Robinson, DL
    Wightman, RM
    [J]. CATECHOLAMINE RESEARCH: FROM MOLECULAR INSIGHTS TO CLINICAL MEDICINE, 2002, 53 : 305 - 308
  • [6] INDWELLING CATHETER FOR INFUSIONS INTO SUBCUTANEOUS TISSUE OF FREELY-MOVING RATS
    MUCHA, RF
    [J]. PHYSIOLOGY & BEHAVIOR, 1980, 24 (03) : 425 - 428
  • [7] SEROTONIN RELEASE ESTIMATED BY TRANSCORTICAL DIALYSIS IN FREELY-MOVING RATS
    CARBONI, E
    DICHIARA, G
    [J]. NEUROSCIENCE, 1989, 32 (03) : 637 - 645
  • [8] DELTAMETHRIN INFUSION INTO DIFFERENT SITES IN THE NEURAXIS OF FREELY-MOVING RATS
    BRODIE, ME
    [J]. NEUROBEHAVIORAL TOXICOLOGY AND TERATOLOGY, 1985, 7 (01): : 51 - 55
  • [9] What controls gain in gain control? Mismatch negativity (MMN), priors and system biases
    Juanita Todd
    Andrew Heathcote
    Daniel Mullens
    Lisa R. Whitson
    Alexander Provost
    István Winkler
    [J]. Brain Topography, 2014, 27 : 578 - 589
  • [10] What controls gain in gain control? Mismatch negativity (MMN), priors and system biases
    Todd, Juanita
    Heathcote, Andrew
    Mullens, Daniel
    Whitson, Lisa R.
    Provost, Alexander
    Winkler, Istvan
    [J]. BRAIN TOPOGRAPHY, 2014, 27 (04) : 578 - 589