320-row CT renal perfusion imaging in patients with aortic dissection: A preliminary study

被引:9
|
作者
Liu, Dongting [1 ]
Liu, Jiayi [1 ]
Wen, Zhaoying [1 ]
Li, Yu [1 ]
Sun, Zhonghua [2 ]
Xu, Qin [3 ]
Fan, Zhanming [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing, Peoples R China
[2] Curtin Univ, Dept Med Radiat Sci, Perth, WA, Australia
[3] Capital Med Univ, Sch Publ Hlth, Beijing, Peoples R China
来源
PLOS ONE | 2017年 / 12卷 / 02期
关键词
DYNAMIC COMPUTED-TOMOGRAPHY; GLOMERULAR-FILTRATION-RATE; A DISSECTION; HEPATOCELLULAR-CARCINOMA; FUNCTIONAL ASSESSMENT; DOSE ESTIMATION; SINGLE-SESSION; TUMORS; HEMODYNAMICS; MALPERFUSION;
D O I
10.1371/journal.pone.0171235
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective To investigate the clinical value of renal perfusion imaging in patients with aortic dissection (AD) using 320-row computed tomography (CT), and to determine the relationship between renal CT perfusion imaging and various factors of aortic dissection. Methods Forty-three patients with AD who underwent 320-row CT renal perfusion before operation were prospectively enrolled in this study. Diagnosis of AD was confirmed by transthoracic echocardiography. Blood flow (BF) of bilateral renal perfusion was measured and analyzed. CT perfusion imaging signs of AD in relation to the type of AD, number of entry tears and the false lumen thrombus were observed and compared. Results The BF values of patients with type A AD were significantly lower than those of patients with type B AD (P = 0.004). No significant difference was found in the BF between different numbers of intimal tears (P = 0.288), but BF values were significantly higher in cases with a false lumen without thrombus and renal arteries arising from the true lumen than in those with thrombus (P = 0.036). The BF values measured between the true lumen, false lumen and overriding groups were different (P = 0.02), with the true lumen group having the highest. Also, the difference in BF values between true lumen and false lumen groups was statistically significant (P = 0.016), while no statistical significance was found in the other two groups (P > 0.05). The larger the size of intimal entry tears, the greater the BF values (P = 0.044). Conclusions This study shows a direct correlation between renal CT perfusion changes and AD, with the size, number of intimal tears, different types of AD, different renal artery origins and false lumen thrombosis, significantly affecting the perfusion values.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] WHOLE BODY IMAGING WITH DYNAMIC VOLUME 320-ROW CT
    Irwan, R.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1067 - 1068
  • [2] Acute stroke rapid imaging protocol by 320-row Area Detector CT
    Mori, T.
    Iwata, T.
    Miyazaki, Y.
    Tanno, Y.
    Kasakuar, S.
    Aoyagi, Y.
    Yosioka, K.
    CEREBROVASCULAR DISEASES, 2014, 37 : 206 - 206
  • [3] Computed Tomography Perfusion Imaging with 320-row Dynamic Volume CT Accurately Detects Obstructive Atherosclerosis Causing Myocardial Perfusion Abnormalities
    George, Richard T.
    Arbab-Zadeh, Armin
    Miller, Julie M.
    Vavere, Andrea L.
    Bengel, Frank M.
    Lardo, Albert C.
    Lima, Joao A.
    CIRCULATION, 2010, 122 (21)
  • [4] Time Efficiency and Diagnostic Accuracy of New Automated Myocardial Perfusion Analysis Software in 320-Row CT Cardiac Imaging
    Rief, Matthias
    Stenzel, Fabian
    Kranz, Anisha
    Schlattmann, Peter
    Dewey, Marc
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (01) : 21 - 29
  • [5] Continuous imaging of esophagogastric junction in patients with reflux esophagitis using 320-row area detector CT: A feasibility study
    Fukazawa, Kousuke
    Furuta, Kenji
    Adachi, Kyoichi
    Shimura, Shino
    Kamiyama, Kazutoshi
    Aimi, Masahito
    Ohara, Shunji
    Kajitani, Takafumi
    Tsurusaki, Masakatsu
    Kitagaki, Hajime
    Kinoshita, Yoshikazu
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 (10) : 1600 - 1607
  • [6] Diagnostic value of 320-row MDCT stress perfusion study in comparison with CMR
    Descalzo, M.
    Leta, R.
    Carreras, F.
    Alomar, X.
    Pujadas, S.
    Teis, A.
    Hidalgo, A.
    Hion-Li, C.
    Segura, L.
    Pons, G.
    EUROPEAN HEART JOURNAL, 2012, 33 : 93 - 93
  • [7] Genuine "one-stop-shop" stress myocardial CT perfusion: taking full advantage of a 320-row CT imaging system
    Zhou, Wanhui
    Yan, Cheng
    Xu, Shijie
    Wang, Wei
    Wang, Wenying
    Zhang, Guozhi
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [8] Low dose 320-row CT for left atrium and pulmonary veins imaging-the feasibility study
    Yang, Lin
    Xu, Lei
    Yan, Zixu
    Yu, Wei
    Fan, Zhanming
    Lv, Biao
    Zhang, Zhaoqi
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1549 - 1554
  • [9] Thoracic Aortic Plaque Burden and Prediction of Cardiovascular Events in Patients Undergoing 320-row Multidetector CT Coronary Angiography
    Otsuka, Kenichiro
    Ishikawa, Hirotoshi
    Yamaura, Hiroki
    Hojo, Kana
    Kono, Yasushi
    Shimada, Kenei
    Kasayuki, Noriaki
    Fukuda, Daiju
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2024, 31 (03) : 273 - 287
  • [10] Image quality and radiation dose of renal perfusion CT with low-dose contrast agent: a comparison with conventional CT using a 320-row system
    Asayama, Y.
    Nishie, A.
    Ishigami, K.
    Ushijima, Y.
    Kakihara, D.
    Fujita, N.
    Morita, K.
    Ishimatsu, K.
    Takao, S.
    Honda, H.
    CLINICAL RADIOLOGY, 2019, 74 (08) : 650.e13 - 650.e18