Photoacoustic detection and optical spectroscopy of high-intensity focused ultrasound-induced thermal lesions in biologic tissue

被引:19
|
作者
Alhamami, Mosa [1 ]
Kolios, Michael C. [1 ]
Tavakkoli, Jahan [1 ]
机构
[1] Ryerson Univ, Dept Phys, 350 Victoria St, Toronto, ON M5B 2K3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
high-intensity focused ultrasound (HIFU); thermal lesions; photoacoustic (PA) detection; optical spectroscopy; optical properties of chicken breast tissue; THERAPEUTIC ULTRASOUND; SURGERY; ABLATION; SYSTEM; BRAIN; COAGULATION; GLAUCOMA; TUMORS; MEDIA;
D O I
10.1118/1.4871621
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aims of this study are: (a) to investigate the capability of photoacoustic (PA) method in detecting high-intensity focused ultrasound (HIFU) treatments in muscle tissues in vitro; and (b) to determine the optical properties of HIFU-treated and native tissues in order to assist in the interpretation of the observed contrast in PA detection of HIFU treatments. Methods: A single-element, spherically concaved HIFU transducer with a centre frequency of 1 MHz was utilized to create thermal lesions in chicken breast tissues in vitro. To investigate the detectability of HIFU treatments photoacoustically, PA detection was performed at 720 and 845 nm on seven HIFU-treated tissue samples. Within each tissue sample, PA signals were acquired from 22 locations equally divided between two regions of interest within two volumes in tissue -a HIFU-treated volume and an untreated volume. Optical spectroscopy was then carried out on 10 HIFU-treated chicken breast specimens in the wavelength range of 500-900 nm, in 1-nm increments, using a spectrophotometer with an integrating sphere attachment. The authors' optical spectroscopy raw data (total transmittance and diffuse reflectance) were used to obtain the optical absorption and reduced scattering coefficients of HIFU-induced thermal lesions and native tissues by employing the inverse addingdoubling method. The aforementioned interaction coefficients were subsequently used to calculate the effective attenuation coefficient and light penetration depth of HIFU-treated and native tissues in the wavelength range of 500-900 nm. Results: HIFU-treated tissues produced greater PA signals than native tissues at 720 and 845 nm. At 720 nm, the averaged ratio of the peak-to-peak PA signal amplitude of HIFU-treated tissue to that of native tissue was 3.68 +/- 0.25 (mean +/- standard error of the mean). At 845 nm, the averaged ratio of the peak-to-peak PA signal amplitude of HIFU-treated tissue to that of native tissue was 3.75 +/- 0.26 (mean +/- standard error of the mean). The authors' spectroscopic investigation has shown that HIFU-treated tissues have a greater optical absorption and reduced scattering coefficients than native tissues in the wavelength range of 500-900 nm. In fact, at 720 and 845 nm, the ratio of the optical absorption coefficient of HIFU-treated tissues to that of native tissues was 1.13 and 1.17, respectively; on the other hand, the ratio of the reduced scattering coefficient of HIFU-treated tissues to that of native tissues was 13.22 and 14.67 at 720 and 845 nm, respectively. Consequently, HIFU-treated tissues have a higher effective attenuation coefficient and a lower light penetration depth than native tissues in the wavelength range 500-900 nm. Conclusions: Using a PA approach, HIFU-treated tissues interrogated at 720 and 845 nm optical wavelengths can be differentiated from untreated tissues. Based on the authors' spectroscopic investigation, the authors conclude that the observed PA contrast between HIFU-induced thermal lesions and untreated tissue is due, in part, to the increase in the optical absorption coefficient, the reduced scattering coefficient and, therefore, the deposited laser energy fluence in HIFU-treated tissues. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Feasibility of optoacoustic visualization of high-intensity focused ultrasound-induced thermal lesions in live tissue
    Chitnis, Parag V.
    Brecht, Hans-Peter
    Su, Richard
    Oraevsky, Alexander A.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)
  • [2] Numerical evaluation of high-intensity focused ultrasound-induced thermal lesions in atherosclerotic plaques
    Lei, Weirui
    Hu, Jiwen
    Liu, Yatao
    Liu, Wenyi
    Chen, Xuekun
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2021, 18 (02) : 1154 - 1168
  • [3] Feasibility study on photoacoustic guidance for high-intensity focused ultrasound-induced hemostasis
    Van Phuc Nguyen
    Kim, Jeehyun
    Ha, Kang-lyeol
    Oh, Junghwan
    Kang, Hyun Wook
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (10)
  • [4] Modeling of high-intensity focused ultrasound-induced lesions in the presence of cavitation bubbles
    Chavrier, F
    Chapelon, JY
    Gelet, A
    Cathignol, D
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (01): : 432 - 440
  • [5] Imaging high-intensity focused ultrasound-induced tissue denaturation by multispectral photoacoustic method: an ex vivo study
    Sun, Yao
    O'Neill, Brian
    APPLIED OPTICS, 2013, 52 (08) : 1764 - 1770
  • [6] Numerical and Experimental Evaluation of High-Intensity Focused Ultrasound-Induced Lesions in Liver Tissue Ex Vivo
    Haddadi, Samaneh
    Ahmadian, Mohammad Taghi
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (06) : 1481 - 1491
  • [7] Imaging of high-intensity focused ultrasound-induced lesions in soft biological tissue using thermoacoustic tomography
    Xing, J
    Xu, Y
    Wang, LV
    Fang, YR
    Zanelli, CI
    Howard, SM
    MEDICAL PHYSICS, 2005, 32 (01) : 5 - 11
  • [8] Nakagami imaging for detecting thermal lesions induced by high-intensity focused ultrasound in tissue
    Rangraz, Parisa
    Behnam, Hamid
    Tavakkoli, Jahan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (01) : 19 - 26
  • [9] High-Intensity Focused Ultrasound-Induced Thermal Effect for Solid Polymer Materials
    Liu, Bo
    Xia, Hesheng
    Fei, Guoxia
    Li, Guo
    Fan, Wenru
    MACROMOLECULAR CHEMISTRY AND PHYSICS, 2013, 214 (22) : 2519 - 2527