Guidelines for current transformers selection for protection systems

被引:0
|
作者
Kojovic, LA [1 ]
机构
[1] Thomas A Edison Tech Ctr, Cooper Power Syst, Franksville, WI 53126 USA
关键词
current transformer; saturation; transient response; protective relaying; digital simulation;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
If current transformer (CT) characteristics are not properly selected for fault conditions, saturation will occur and relays can misoperate. To help protection engineers select the appropriate CT, the IEEE published two documents on CT performance and application. This paper compares the guidelines in these two documents and suggests modifications that will make CT selection easier and more realistically estimate CT time-to-saturation.
引用
收藏
页码:593 / 598
页数:4
相关论文
共 50 条
  • [1] SELECTION AND PROTECTION OF CURRENT TRANSFORMERS FOR USE IN SHUNT CAPACITOR BANKS
    HARDER, JE
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (06): : 1760 - 1760
  • [2] Current Transformers in Protection Applications
    Ristanovic, Dragan
    Tadlock, Terry
    Bhatt, Gautami
    [J]. IEEE INDUSTRY APPLICATIONS MAGAZINE, 2021, 27 (05) : 47 - 57
  • [3] ELECTRONIC PROTECTION SYSTEMS FOR TRANSFORMERS
    STROBL, J
    [J]. ELIN ZEITSCHRIFT, 1977, 29 (03): : 114 - 115
  • [4] PERFORMANCE OF COMPARISON-PROTECTION SYSTEMS DURING TRANSIENT SATURATIONS OF CURRENT TRANSFORMERS
    WINKLER, W
    [J]. ETZ ARCHIV, 1988, 10 (10): : 325 - 329
  • [5] Current Status and Future of Instrument Transformers and Related Technologies in Protection and Control Systems
    Harada K.
    [J]. IEEJ Transactions on Power and Energy, 2022, 142 (12) : 570 - 575
  • [6] On the requirements of current transformers in differential protection of transformers at electric power stations
    Dmitrenko A.M.
    Zhuravlev D.P.
    [J]. Power Technology and Engineering, 2017, 50 (6) : 662 - 667
  • [7] Sizing Current Transformers for Line Protection Applications
    Altuve, Hector J.
    Fischer, Normann
    Benmouyal, Gabriel
    Finney, Dale
    [J]. 2013 66TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2013, : 36 - 51
  • [8] RESIDUAL INDUCTION OF CURRENT TRANSFORMERS IN RELAY PROTECTION
    BAEV, AV
    [J]. ELECTRICAL TECHNOLOGY, 1971, 3 : 8 - &
  • [9] Evaluation of Current Transformers and Protection Relay Circuit
    Lazecky, David
    Rusek, Stanislav
    Gono, Radomir
    Kral, Vladimir
    Leonowicz, Zbigniew
    [J]. 2020 20TH IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2020 4TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2020,
  • [10] Selection of current transformers and wire sizing in substations
    Ganesan, Sethuraman
    [J]. 2006 59TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2006, : 124 - 133