Validation of the whole-body counting measurement in a radiation emergency

被引:2
|
作者
Park, MinSeok [1 ]
Kim, Min-sub [1 ]
Yoo, Jaeryong [1 ]
Jo, Min-su [1 ]
机构
[1] Korea Inst Radiol & Med Sci, Natl Radiat Emergency Ctr, Seoul 01812, South Korea
关键词
Whole-body measurement; Validation; Radioactivity; Internal contamination;
D O I
10.1016/j.apradiso.2020.109476
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Whole-body measurement can provide fast and accurate results in radiation emergencies. The whole-body counting method needs to be validated to guarantee the reliability and accuracy of the measurement. This study provides data related to the validation of the whole-body measurement using the stand-up type whole-body counter. Several parameters, including the sensitivity, accuracy, uncertainty, were considered for validation. The results indicate that the method of whole-body measurement is reliable for assessment of internal contamination.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] MEASUREMENT OF IRON ABSORPTION BY WHOLE-BODY COUNTING
    COOK, JD
    PALMER, HE
    PAILTHORP, KG
    FINCH, CA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (03): : 467 - +
  • [2] WHOLE-BODY COUNTING
    ROESCH, WC
    [J]. HEALTH PHYSICS, 1965, 11 (09): : 945 - +
  • [3] AUTOMATED-ANALYSIS IN WHOLE-BODY COUNTING OF RADIATION WORKERS
    HAVLIK, E
    BERGMANN, H
    HOFER, R
    [J]. ACTA PHYSICA HUNGARICA, 1986, 59 (1-2) : 11 - 14
  • [4] SIMPLIFIED WHOLE-BODY COUNTING
    PALMER, HE
    [J]. HEALTH PHYSICS, 1966, 12 (01): : 95 - +
  • [5] CLINICAL WHOLE-BODY COUNTING - WHOLE-BODY SCANNER WITH 2 CRYSTALS
    REIZENSTEIN, P
    KARLSSON, HA
    [J]. ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1966, 4 (03): : 209 - +
  • [6] MEASUREMENT OF WHOLE-BODY CELLULAR AND COLLAGEN NITROGEN, POTASSIUM, AND OTHER ELEMENTS BY NEUTRON-ACTIVATION AND WHOLE-BODY COUNTING
    JAMES, HM
    FABRICIUS, PJ
    DYKES, PW
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1987, 11 (05) : S48 - S50
  • [7] MEASUREMENT OF RETENTION OF BONE-SEEKING ISOTOPES BY WHOLE-BODY COUNTING
    BURKINSH.L
    WILSON, AR
    NORDIN, BEC
    OXBY, CB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 167 - &
  • [8] WHOLE-BODY COUNTING - A NEW PERSPECTIVE
    MCCURDY, DE
    MELLOR, RA
    HARRINGTON, CL
    BARD, ST
    [J]. HEALTH PHYSICS, 1984, 47 (01): : 135 - 135
  • [9] WHOLE-BODY COUNTING OF PLUTONIUM IN DOGS
    SWINTH, KL
    GRIFFIN, BI
    PARK, JF
    [J]. HEALTH PHYSICS, 1965, 11 (08): : 824 - +
  • [10] RADIONUCLIDE METROLOGY IN WHOLE-BODY COUNTING
    MASSE, FX