Numerical study on transient supercooling performance of annular thermoelectric cooler

被引:19
|
作者
Gao, Yan-Wei [1 ]
Shi, Cong-Ling [1 ]
Wang, Xiao-Dong [2 ,3 ]
机构
[1] China Acad Safety Sci & Technol, Beijing Key Lab Metro Fire & Passenger Transporta, Beijing 100012, Peoples R China
[2] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[3] North China Elect Power Univ, Res Ctr Engn Thermophys, Beijing 102206, Peoples R China
关键词
Transient supercooling; ATEC; 3D transient model; Variable properties; PULSE; MODEL; SIMULATION; OPERATION; GENERATOR; BEHAVIOR; POWER;
D O I
10.1016/j.applthermaleng.2020.116090
中图分类号
O414.1 [热力学];
学科分类号
摘要
Transient supercooling can effectively improve the performance of thermoelectric coolers (TECs), especially seen from the studies on flat-plate TECs. But for an annular facility, annular thermoelectric coolers (ATECs) are a better choice because their annular structures increase contact areas. For further studying it, a 3D transient model coupling temperature field and electric potential field is established to study the effects of pulse current amplitude (P), pulse width (tau), annular thermoelectric angle (theta), leg length (r) of thermoelectric element, convective heat transfer coefficient (h) and pulse current shape on the transient performance of ATEC made of variable properties materials. The results show that P and tau are still key factors for the said ATEC, let the P is constant, there is an optimal pulse width minimizing the cold end temperature. If the annular thermoelectric angle theta increases, ATEC with a cold end cross-sectional area larger than that of the hot end makes the supercooling poorer. Let the leg lengths r of the ATEC are 0.8 mm and 0.7 mm respectively, the minimum cold end temperatures (T-c,T-min) are 236.41 K and 246.18 K as the cross-sectional area of the cold end gets smaller but larger than that of the hot end. The larger of the his, the better the heat will be dissipated from the hot end of the ATEC, till a certain value of ft, the transient performance no longer changes significantly for no much more heat could be dissipated. As the study shown, applying different pulse current shapes leads to the acquisition of different supercooling indicators.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Numerical study of transient supercooling performance and thermal stress analysis of segmented annular thermoelectric cooler
    Mu, Lin
    Zhang, Hu
    Cui, Jiale
    Zhao, Junfeng
    Shang, Yan
    Pu, Hang
    Dong, Ming
    [J]. APPLIED THERMAL ENGINEERING, 2024, 245
  • [2] Numerical Study on Cooling Performance of Aerocraft Annular Thermoelectric Cooler
    Mu, Lin
    Zhang, Hu
    Cui, Jiale
    Pu, Hang
    Dong, Ming
    Shang, Yan
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (04): : 1114 - 1124
  • [3] Experimental study on transient supercooling of two-stage thermoelectric cooler
    Li, Wen-Ken
    Chang, Jhih-Hao
    Amani, Mohammad
    Yang, Tien-Fu
    Yan, Wei-Mon
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2019, 14
  • [4] Optimal pulse current shape for transient supercooling of thermoelectric cooler
    Lv, Hao
    Wang, Xiao-Dong
    Wang, Tian-Hu
    Meng, Jing-Hui
    [J]. ENERGY, 2015, 83 : 788 - 796
  • [5] Numerical analysis for transient supercooling effect of pulse current shapes on a two-stage thermoelectric cooler
    Gao, Yan-Wei
    Shi Cong-Ling
    Wang Xiao-Dong
    [J]. APPLIED THERMAL ENGINEERING, 2019, 163
  • [6] Performance study of thermoelectric cooler using multiphysics simulation and numerical modelling
    Panigrahi N.
    Venkatesan K.
    Venkata Ramanan M.
    [J]. International Journal of Ambient Energy, 2021, 42 (14) : 1600 - 1606
  • [7] A numerical study on the performance of miniature thermoelectric cooler affected by Thomson effect
    Chen, Wei-Hsin
    Liao, Chen-Yeh
    Hung, Chen-I
    [J]. APPLIED ENERGY, 2012, 89 (01) : 464 - 473
  • [8] Numerical simulation on thermoelectric and mechanical performance of annular thermoelectric generator
    Fan, Shifa
    Gao, Yuanwen
    [J]. ENERGY, 2018, 150 : 38 - 48
  • [9] Transient supercooling performance of thermoelectric coolers with a continuous double current pulse
    Wang, Shuo-Lin
    Liu, Hai-Bo
    Gao, Yan-Wei
    Shen, Yuan
    Yang, Yan-Ru
    Wang, Xiao-Dong
    Lee, Duu-Jong
    [J]. JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2021, 120 : 127 - 135
  • [10] Numerical and experimental analysis of transient supercooling effect of voltage pulse on thermoelectric element
    Shen, L. M.
    Xiao, F.
    Chen, H. X.
    Wang, S. W.