Experimental Determination of Frost Resistance of Autoclaved Aerated Concrete at Different Levels of Moisture Saturation

被引:3
|
作者
Koci, Vaclav [1 ]
Madera, Jiri [1 ]
Jerman, Milos [1 ]
Cerny, Robert [1 ]
机构
[1] Czech Tech Univ, Fac Civil Engn, Dept Mat Engn & Chem, Thakurova 7-2077, Prague, Czech Republic
关键词
Autoclaved aerated concrete; Frost resistance; Low temperatures; Material properties; Partial water saturation; HYGROTHERMAL PERFORMANCE; DAMAGE;
D O I
10.1007/s10765-018-2398-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
The ability of porous building materials to stand up to moisture phase changes induced by alternating environment is described mostly by means of their frost resistance. However, the test conditions defined by relevant standards might not capture the real situation on building site in various locations. In particular, the prescribed full water saturation of analyzed specimens during the whole time of a freeze/thaw experiment presents an ultimate case only but certainly not an everyday reality. Even the materials of surface layers are mostly exposed to such severe conditions just for a limited period of time. In this paper, the experimental analysis of frost resistance of three different types of autoclaved aerated concrete (AAC) is performed in an extended way, including not only the standard testing but also the investigation of dry- and partially saturated samples. A complementary computational analysis of an AAC building envelope in Central European climate is presented as well, in order to illustrate the likely hygric conditions in the wall. Experimental results show that according to the standard test the loss of compressive strength, as well as the loss of mass after 25 cycles, is acceptable for all studied samples but after 50 cycles only the material with the compressive strength of 4 MPa performs satisfactorily. On the other hand, the tests with initially dried or partially saturated samples indicate a good frost resistance of all studied materials for both 25 and 50 cycles.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Experimental Determination of Frost Resistance of Autoclaved Aerated Concrete at Different Levels of Moisture Saturation
    Václav Kočí
    Jiří Maděra
    Miloš Jerman
    Robert Černý
    International Journal of Thermophysics, 2018, 39
  • [2] Development of a standard for accelerated determination of frost resistance of autoclaved aerated concrete
    Lapovska, Svitlana
    Klapchenko, Vasyl
    Demchenko, Tetyana
    ce/papers, 2023, 6 (02) : 299 - 302
  • [3] Determination of length changes due to moisture variations in autoclaved aerated concrete
    Gottfredsen, F.R.
    Knutsson, H.H.
    Nielsen, A.
    Materials and Structures/Materiaux et Constructions, 1997, 30 (197): : 148 - 153
  • [4] Determination of length changes due to moisture variations in autoclaved aerated concrete
    Gottfredsen, FR
    Knutsson, HH
    Nielsen, A
    MATERIALS AND STRUCTURES, 1997, 30 (197) : 148 - 153
  • [5] Determination of length changes due to moisture variations in autoclaved aerated concrete
    F. R. Gottfredsen
    H. H. Knutsson
    A. Nielsen
    Materials and Structures, 1997, 30 : 148 - 153
  • [6] Methods for moisture storage and transport property determination of autoclaved aerated concrete
    Scheffler, Gregor A.
    Plagge, Rudolf
    CEMENT WAPNO BETON, 2011, : 70 - 77
  • [7] Experimental determination and fractal modeling of the effective thermal conductivity of autoclaved aerated concrete: Effects of moisture content
    Jin, Hong-Qing
    Yao, Xiao-Li
    Fan, Li-Wu
    Xu, Xu
    Yu, Zi-Tao
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 92 : 589 - 602
  • [8] Experimental Investigation of Autoclaved Aerated Concrete Masonry
    Bhosale, Avadhoot
    Zade, Nikhil P.
    Davis, Robin
    Sarkar, Pradip
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2019, 31 (07)
  • [9] Water absorptivity and frost resistance performance of self-ignition coal gangue autoclaved aerated concrete
    Cong X.
    Tan Y.
    Lu S.
    Wang Z.
    Huang T.
    Lu, Shuang (hitlu@126.com); Wang, Zhaojia (wangzhaojia@bbmg.com.cn), 1600, Springer Nature (02):
  • [10] Experimental Study on the Interrelationship between the Moisture Content and Drying Shrinkage of Autoclaved Aerated Concrete Wallboard
    Yang, Jianyu
    Zou, Jiaming
    Yang, Weijun
    Yi, Sirong
    Liu, Jinzhao
    MATERIALS, 2022, 15 (16)