A non-enzymatic glucose sensor enabled by bioelectronic pH control

被引:79
|
作者
Strakosas, Xenofon [1 ]
Selberg, John [1 ]
Pansodtee, Pattawong [1 ]
Yonas, Nebyu [1 ]
Manapongpun, Pattawut [1 ]
Teodorescu, Mircea [1 ]
Rolandi, Marco [1 ]
机构
[1] Univ Calif Santa Cruz, Dept Elect & Comp Engn, Santa Cruz, CA 95064 USA
关键词
ELECTROCHEMICAL SENSORS; BIOSENSORS; SWEAT;
D O I
10.1038/s41598-019-46302-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Continuous glucose monitoring from sweat and tears can improve the quality of life of diabetic patients and provide data for more accurate diagnosis and treatment. Current continuous glucose sensors use enzymes with a one-to-two week lifespan, which forces periodic replacement. Metal oxide sensors are an alternative to enzymatic sensors with a longer lifetime. However, metal oxide sensors do not operate in sweat and tears because they function at high pH (pH > 10), and sweat and tears are neutral (pH = 7). Here, we introduce a non-enzymatic metal oxide glucose sensor that functions in neutral fluids by electronically inducing a reversible and localized pH change. We demonstrate glucose monitoring at physiologically relevant levels in neutral fluids mimicking sweat, and wireless communication with a personal computer via an integrated circuit board.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A non-enzymatic glucose sensor enabled by bioelectronic pH control
    Xenofon Strakosas
    John Selberg
    Pattawong Pansodtee
    Nebyu Yonas
    Pattawut Manapongpun
    Mircea Teodorescu
    Marco Rolandi
    [J]. Scientific Reports, 9
  • [2] Simultaneous pH and glucose sensing and its relation in a non-enzymatic glucose sensor
    Pablo Tirado Cantu
    Jesus Javier Alcantar Peña
    Alexis Cruz Zabalegui
    A. M. Jocelyn
    Gilberto Martínez Saucedo
    Daniela Díaz Alonso
    I. R. Chávez-Urbiola
    [J]. MRS Communications, 2024, 14 : 96 - 102
  • [3] Simultaneous pH and glucose sensing and its relation in a non-enzymatic glucose sensor
    Cantu, Pablo Tirado
    Pena, Jesus Javier Alcantar
    Zabalegui, Alexis Cruz
    Jocelyn, A. M.
    Saucedo, Gilberto Martinez
    Alonso, Daniela Diaz
    Chavez-Urbiola, I. R.
    [J]. MRS COMMUNICATIONS, 2024, 14 (01) : 96 - 102
  • [4] A novel sensitive non-enzymatic glucose sensor
    Xin Huang Kang
    [J]. Chinese Chemical Letters, 2007, (02) : 189 - 191
  • [5] Pd nanocube as non-enzymatic glucose sensor
    Ye, Jyun-Sian
    Chen, Chin-Wei
    Lee, Chien-Liang
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 569 - 574
  • [6] A novel sensitive non-enzymatic glucose sensor
    Kang, Xin Huang
    Mai, Zhi Bin
    Zou, Xiao Yong
    Cai, Pei Xiang
    Mo, Jin Yuan
    [J]. CHINESE CHEMICAL LETTERS, 2007, 18 (02) : 189 - 191
  • [7] Dual functional rhodium oxide nanocorals enabled sensor for both non-enzymatic glucose and solid-state pH sensing
    Dong, Qiuchen
    Huang, Yikun
    Song, Donghui
    Wu, Huixiang
    Cao, Fei
    Lei, Yu
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 112 : 136 - 142
  • [8] Carbon nanoparticles based non-enzymatic glucose sensor
    Pulidindi, Indra Neel
    Gedanken, Aharon
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (01) : 28 - 35
  • [9] Numerical Modeling on Non-enzymatic, Potentiometric Glucose Sensor
    Kanagasabapathy, M.
    Bapu, G. N. K. Ramesh
    Linga, Praveen
    Gnanamuthu, R. M.
    [J]. PORTUGALIAE ELECTROCHIMICA ACTA, 2012, 30 (04) : 295 - 306
  • [10] Nanostructured Gold Microelectrodes for Non-enzymatic Glucose Sensor
    Hovancova, Jana
    Sisolakova, Ivana
    Vanysek, Petr
    Orinakova, Renata
    Shepa, Ivan
    Vojtko, Marek
    Orinak, Andrej
    [J]. ELECTROANALYSIS, 2019, 31 (09) : 1680 - 1689