Does central venous pressure reflect the circulating blood volume for the decrement of compliance just after esophagectomy?

被引:7
|
作者
Motoyama, S [1 ]
Kitamura, M [1 ]
Kibira, S [1 ]
Suzuki, H [1 ]
Kamata, S [1 ]
Saito, R [1 ]
Kimura, K [1 ]
Sasaki, S [1 ]
Taguchi, K [1 ]
Okuyama, M [1 ]
Miura, M [1 ]
Ogawa, J [1 ]
机构
[1] Akita Univ, Sch Med, Dept Surg 2, Akita 0108543, Japan
来源
关键词
central venous pressure; central venous diameter; central venous compliance; circulating blood volume; esophagectomy;
D O I
10.1007/PL00010039
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study investigates whether the pressure parameters obtained from the Swan-Ganz catheter (SGC) accurately reflect the circulating blood volume just after en bloc resection of the thoracic esophagus with regional lymph node dissection. It is well known that this operation induces severe hemodynamic changes and although the pressure parameters obtained from the SGC are an accepted means of monitoring circulating blood volume, we have often experienced a discrepancy between the SGC data and the clinical state. We examined the pressure parameters and diameter of the inferior vena cava (IVC) and left ventricle (LV), and the central venous compliance using SGC and echocardiography in ten patients who underwent esophagectomy for esophageal cancer. The central venous pressure, pulmonary arterial mean pressure, and pulmonary artery wedged pressure were significantly increased just after the operation compared with the preoperative levels, while the diameters of the IVC and LV decreased just after the operation. The compliances of the NC decreased significantly just after the operation. The hemodynamic shift to the third space after esophagectomy induces decrement of the compliances of IVC, As the CVP does not always reflect the circulating blood volume, measuring the diameter of the IVC using echocardiography is extremely useful for monitoring circulating blood volume just after esophagectomy.
引用
收藏
页码:11 / 15
页数:5
相关论文
共 50 条
  • [1] Does Central Venous Pressure Reflect the Circulating Blood Volume for the Decrement of Compliance Just After Esophagectomy?
    Satoru Motoyama
    Michihiko Kitamura
    Satoshi Kibira
    Hiroyuki Suzuki
    Shuichi Kamata
    Reijiro Saito
    Keisuke Kimura
    Shinichi Sasaki
    Kousei Taguchi
    Manabu Okuyama
    Mamoru Miura
    Jun-ichi Ogawa
    [J]. Surgery Today, 2000, 30 : 11 - 15
  • [2] Does central venous pressure or pulmonary capillary wedge pressure reflect the status of circulating blood volume in patients after extended transthoracic esophagectomy?
    Oohashi S.
    Endoh H.
    [J]. Journal of Anesthesia, 2005, 19 (1) : 21 - 25
  • [3] CENTRAL VENOUS-PRESSURE DOES NOT REFLECT CHANGES IN CIRCULATING BLOOD-VOLUME FOLLOWING ANEURYSMAL SUBARACHNOID HEMORRHAGE
    MAYER, SA
    FINK, ME
    LENNIHAN, L
    KLEBANOFF, LM
    BECKFORD, A
    PROHOVNIK, L
    YOUNG, W
    SOLOMON, RA
    [J]. ANNALS OF NEUROLOGY, 1992, 32 (02) : 239 - 239
  • [4] CENTRAL VENOUS PRESSURE AND BLOOD-VOLUME
    DAVIES, DM
    [J]. LANCET, 1971, 1 (7689): : 85 - &
  • [5] CENTRAL VENOUS PRESSURE AND BLOOD-VOLUME
    ELIAHOU, HE
    WEINBERG, U
    REISIN, E
    IAINA, A
    ZIPERKOWSKI, M
    [J]. LANCET, 1970, 2 (7685): : 1252 - +
  • [6] CENTRAL VENOUS PRESSURE AND BLOOD-VOLUME
    JOHNSON, HD
    DEBONO, AHB
    [J]. LANCET, 1966, 2 (7465): : 701 - &
  • [7] DOES CENTRAL VENOUS-PRESSURE ACCURATELY REFLECT HEMODYNAMIC AND FLUID VOLUME PATTERNS IN CRITICAL SURGICAL PATIENT
    DELAURENTIS, DA
    HAYES, M
    MATSUMOTO, T
    WOLFERTH, CC
    [J]. AMERICAN JOURNAL OF SURGERY, 1973, 126 (03): : 415 - 418
  • [8] VENOUS-PRESSURE AS AN INDICATOR OF THE CIRCULATING BLOOD-VOLUME
    NEKHAEV, AS
    DEGTYAREV, VA
    BEDNENKO, VS
    [J]. KOSMICHESKAYA BIOLOGIYA I AVIAKOSMICHESKAYA MEDITSINA, 1982, 16 (02): : 91 - 92
  • [9] SHOCK - BLOOD VOLUME VS CENTRAL VENOUS PRESSURE
    MOSTERT, JW
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1969, 280 (01): : 51 - &
  • [10] CENTRAL VENOUS PRESSURE AND BLOOD VOLUME IN CLINICAL SHOCK
    BIRKS, R
    WILSON, RF
    [J]. CIRCULATION, 1968, 38 (4S6) : VI42 - &