Hotelling's T2 control chart with double warning lines

被引:29
|
作者
Faraz, Afireza [1 ]
Parsian, Ahmad
机构
[1] Aerosp Ind Org, Qual Management Dept, Tehran, Iran
[2] Univ Tehran, Sch Math Stat & Comp Sci, Tehran, Iran
关键词
Double Warning Lines Scheme; Markov chain process; multivariate T-2 control chart; multivariate; quality control; variable sampling plan;
D O I
10.1007/s00362-006-0307-x
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Recent studies have shown that the T-2 control chart with variable sampling intervals (VSI) and/or variable sample sizes (VSS) detects process shifts faster than the traditional T-2 chart. This article extends these studies for processes that are monitored with VSI and VSS using double warning lines (T-2 - DWL). it is assumed that the length of time the process remains in control has exponential distribution. The properties of T-2 - DWL chart are obtained using Markov chains. The results show that the T-2 - DWL chart is quicker than VSI and/or VSS charts in detecting almost all shifts in the process mean.
引用
收藏
页码:569 / 593
页数:25
相关论文
共 50 条
  • [1] Hotelling’s T2 control chart with double warning lines
    Alireza Faraz
    Ahmad Parsian
    [J]. Statistical Papers, 2006, 47 : 569 - 593
  • [2] Economic Statistical Design of a T2 Control Chart with Double Warning Lines
    Faraz, Alireza
    Saniga, Erwin
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2011, 27 (02) : 125 - 139
  • [3] Bivariate copulas on the Hotelling's T2 control chart
    Sukparungsee, Saowanit
    Kuvattana, Sasigarn
    Busababodhin, Piyapatr
    Areepong, Yupaporn
    [J]. COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2018, 47 (02) : 413 - 419
  • [4] A Robust Bivariate Control Chart Alternative to the Hotelling's T2 Control Chart
    Abu-Shawiesh, Moustafa Omar Ahmed
    Kibria, B. M. Golam
    George, Florence
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2014, 30 (01) : 25 - 35
  • [5] Hotelling's T2 control chart with variable sampling intervals
    Aparisi, F
    Haro, CL
    [J]. INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2001, 39 (14) : 3127 - 3140
  • [6] A comparison of robust alternatives to Hotelling's T2 control chart
    Alfaro, J. L.
    Ortega, J. Fco
    [J]. JOURNAL OF APPLIED STATISTICS, 2009, 36 (12) : 1385 - 1396
  • [7] Construction of Bivariate Copulas on the Hotelling's T2 Control Chart
    Tiengket, Sanpet
    Sukparungsee, Saowanit
    Busababodhin, Piyapatr
    Areepong, Yupaporn
    [J]. THAILAND STATISTICIAN, 2020, 18 (01): : 1 - 15
  • [8] The Effect of Autocorrelation on the Hotelling T2 Control Chart
    Vanhatalo, Erik
    Kulahci, Murat
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2015, 31 (08) : 1779 - 1796
  • [9] Signal interpretation in Hotelling's T2 control chart for compositional data
    Vives-Mestres, Marina
    Daunis-i-Estadella, Josep
    Martin-Fernandez, Josep-Antoni
    [J]. IIE TRANSACTIONS, 2016, 48 (07) : 661 - 672
  • [10] Hotelling’s T2 control chart with two adaptive sample sizes
    Alireza Faraz
    M. B. Moghadam
    [J]. Quality & Quantity, 2009, 43