Development and validation of a measurement system for continuously monitoring postoperative reservoir levels

被引:1
|
作者
Eichhorn, S. [1 ,2 ]
Reisinger, T. [1 ,2 ]
Boehm, J. [1 ,2 ]
Voss, S. [1 ,2 ]
Doppler, S. [1 ,2 ]
Lange, R. [1 ,2 ,3 ]
Krane, M. [1 ,2 ,3 ]
机构
[1] Tech Univ Munich, German Heart Ctr Munich, Dept Cardiovasc Surg, Lazarettstr 36, D-80636 Munich, Germany
[2] Tech Univ Munich, INSURE Inst Translat Cardiac Surg, Dept Cardiovasc Surg, Lothstr 11, D-80636 Munich, Germany
[3] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, D-80636 Munich, Germany
关键词
Postoperative monitoring; Surgical reservoir; Measurement system; CARDIAC-SURGERY; BLOOD; RISK; REEXPLORATION; TRANSFUSION;
D O I
10.1007/s13246-019-00746-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Following cardiac surgical procedures, multiple drainage systems remain in place inside the patient's chest to prevent the development of pericardial effusion or pneumothorax. Therefore, postoperative bleeding must be diligently observed. Currently, observation of the exudate rate is performed through periodical visual inspection of the reservoir. To improve postoperative monitoring, a measurement system based on load cells was developed to automatically detect bleeding rates. A reservoir retaining bracket was instrumented with a load cell. The signal was digitized by a microcontroller and then processed and displayed on customized software written in LabView. In cases where bleeding rates reach critical levels, the device will automatically sound an alarm. Additionally, the bleeding rate is displayed on the screen with the status of the alarm, as well as the fluid level of the reservoir. These data are all logged to a file. The measurement system has been validated for gain stability and drift, as well as for sensor accuracy, with different in vitro examinations. Additionally, performance of the measurement device was tested in a clinical pilot study on patients recovering from cardiac surgical procedures. The in vitro investigation showed that the monitoring device had excellent gain and drift stability, as well as sensor accuracy, with a resolution of 2.6mL/h for the bleeding rate. During the clinical examination, bleeding rates of all patients were correctly measured. Continuously recording drainage volume using the developed system was comparable to manual measurements performed every 30min by a nurse. Implementation of continuous digital measurements could improve patient safety and reduce the workload of medical professionals working in intensive care units.
引用
收藏
页码:611 / 617
页数:7
相关论文
共 50 条
  • [1] Development and validation of a measurement system for continuously monitoring postoperative reservoir levels
    S. Eichhorn
    T. Reisinger
    J. Böhm
    S. Voss
    S. Doppler
    R. Lange
    M. Krane
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 611 - 617
  • [2] Reliable and economical system of technological measurement of reservoir levels
    Gerasimov, PN
    Dunaev, AA
    NEFTYANOE KHOZYAISTVO, 2000, (10): : 117 - 117
  • [3] Measurement System Development for Geotechnical Monitoring
    Pies, M.
    Hajovsky, R.
    SENSORS AND ELECTRONIC INSTRUMENTATION ADVANCES (SEIA' 19), 2019, : 106 - 112
  • [4] Development and Validation of a Distance Measurement System in Metro Lines
    Song, Haifeng
    Schnieder, Eckehard
    IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2019, 20 (02) : 441 - 456
  • [5] Development and Validation of an Autonomous System for Measurement of Sunshine Duration
    da Rocha, Alvaro B.
    Fernandes, Eisenhawer de M.
    dos Santos, Carlos A. C.
    Diniz, Julio M. T.
    Junior, Wanderley F. A.
    SENSORS, 2020, 20 (16) : 1 - 12
  • [6] Development and Validation of a Measurement System for Laparoscopic Surgical Procedures
    Ebina K.
    Abe T.
    Komizunai S.
    Tsujita T.
    Sase K.
    Chen X.
    Higuchi M.
    Furumido J.
    Iwahara N.
    Kurashima Y.
    Shinohara N.
    Konno A.
    SICE Journal of Control, Measurement, and System Integration, 2020, 13 (04) : 191 - 200
  • [7] POSTOPERATIVE MONITORING SYSTEM
    WELKOWITZ, W
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1964, 118 (A7) : 400 - +
  • [8] Development and Validation of a Distress Measurement Related to Glucose Monitoring of Diabetes Patients
    Choi, Eujin
    Kim, Sooyeon
    Cho, Juhee
    Kim, Min-Sun
    Kwon, Eun Kyung
    Kim, Youngha
    Kang, Danbee
    Cho, Sung Yoon
    DIABETES THERAPY, 2023, 14 (04) : 737 - 748
  • [9] Development and Validation of a Distress Measurement Related to Glucose Monitoring of Diabetes Patients
    Eujin Choi
    Sooyeon Kim
    Juhee Cho
    Min-Sun Kim
    Eun Kyung Kwon
    Youngha Kim
    Danbee Kang
    Sung Yoon Cho
    Diabetes Therapy, 2023, 14 : 737 - 748
  • [10] Development and Application of Dam Safety Monitoring Automatic System of Xianlin Reservoir
    Yao Kangkang
    Zhang Yulun
    Gao Chao
    Fangxushun
    Hou Wenang
    PROCEEDINGS OF THE 2017 3RD INTERNATIONAL FORUM ON ENERGY, ENVIRONMENT SCIENCE AND MATERIALS (IFEESM 2017), 2017, 120 : 429 - 434