Estimation of blood glucose by non-invasive method using photoplethysmography

被引:31
|
作者
Habbu, Shraddha [1 ,2 ]
Dale, Manisha [3 ]
Ghongade, Rajesh [4 ]
机构
[1] AISSMS Inst Informat Technol, Dept Elect & Telecommun, Pune, Maharashtra, India
[2] Vishwakarma Inst Informat Technol, Dept Elect & Telecommun, Pune, Maharashtra, India
[3] Modern Educ Soc Coll Engn, Dept Elect & Telecommun, Pune, Maharashtra, India
[4] Bharati Vidyapeeths Deemed Univ, Dept Elect & Telecommun, Coll Engn, Pune, Maharashtra, India
关键词
Blood glucose measurement; non-invasive; blood glucose level (BGL); neural network; photoplethysmograph (PPG); single pulse analysis (SPA); PULSE; PRESSURE; WAVE;
D O I
10.1007/s12046-019-1118-9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a system which estimates blood glucose level (BGL) by non-invasive method using Photoplethysmography (PPG). Previous studies have shown better estimation of blood glucose level using an optical sensor. An optical sensor based data acquisition system is built and the PPG signal of the subjects is recorded. The main contribution of this paper is exploring various features of a PPG signal using Single Pulse Analysis technique for effective estimation of BGL values. A PPG data of 611 individuals is recorded over duration of 3 minutes each. BGL value estimation is performed using two types of feature sets, (i) Time and frequency domain features and (ii) Single Pulse Analysis (SPA). Neural network is trained using above mentioned proposed feature sets and BGL value estimation is performed. First we validate our methodology using the same features used by Monte Moreno in his earlier work. The experimentation is performed on our own dataset. We obtained comparable results of BGL value estimation as compared with Monte Moreno, with maximum R-2=0.81. Further, BGL estimation using (i) Time and frequency domain features and (ii) Single Pulse Analysis (SPA) is performed and the resulting coefficient of determination (i.e., R-2) obtained for reference vs. prediction are 0.84 and 0.91, respectively. Clarke Error Grid analysis for BGL estimation is clinically accepted, so we performed similar analysis. Using Time and frequency domain feature set, the distributions of data samples is obtained as 80.6% in class A and 17.4% in class B. 1% samples in zone C and Zone D. For Single Pulse Analysis technique (SPA) the distribution of data samples are 83% in class A and 17% in class B. The proposed features in SPA have shown significant improvement in R-2 and Clarke Error grid analysis. SPA technique with the proposed feature set is a good choice for the implementation of system for measurement of non-invasive glucometer.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Estimation of blood glucose by non-invasive method using photoplethysmography
    Shraddha Habbu
    Manisha Dale
    Rajesh Ghongade
    [J]. Sādhanā, 2019, 44
  • [2] Non-invasive Estimation of Blood Glucose
    Sidley, Matthew
    Venkataraman, Jayanti
    [J]. 2013 IEEE APPLIED ELECTROMAGNETICS CONFERENCE (AEMC), 2013,
  • [3] A Machine Learning Approach to the Non-Invasive Estimation of Continuous Blood Pressure Using Photoplethysmography
    Tarifi, Basheq
    Fainman, Aaron
    Pantanowitz, Adam
    Rubin, David M.
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (06):
  • [4] NON-INVASIVE GLUCOSE MONITORING BY MEANS OF PHOTOPLETHYSMOGRAPHY
    Newberry, R.
    Jantz, J.
    Hanna, M.
    Demircik, F.
    Pfuetzner, A.
    Pfuetzner, A.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A136 - A136
  • [5] Nonlinear features of photoplethysmography signals for Non-invasive blood pressure estimation
    Shoeibi, Fatemeh
    Najafiaghdam, Esmaeil
    Ebrahimi, Afshin
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 85
  • [6] Continuous Non-Invasive Blood Pressure Monitoring Using Photoplethysmography
    Nye, Ross
    Zhang, Zhe
    Fang, Qiang
    [J]. 2015 INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2015, : 176 - 179
  • [7] Non-Invasive Blood Pressure Estimation from Photoplethysmography Signals using Artificial Neural Networks
    Bersano, Nicolas
    Sanson, Horacio
    [J]. 2018 20TH INTERNATIONAL CONFERENCE ON ADVANCED COMMUNICATION TECHNOLOGY (ICACT), 2018, : 29 - 35
  • [8] Non-invasive Blood Glucose Estimation Methodology Using Predictive Glucose Homeostasis Models
    Panwar, Madhuri
    Acharyya, Amit
    Shafik, Rishad A.
    [J]. PROCEEDINGS OF THE 2018 8TH INTERNATIONAL SYMPOSIUM ON EMBEDDED COMPUTING AND SYSTEM DESIGN (ISED 2018), 2018, : 167 - 172
  • [9] Non-Invasive Classification of Blood Glucose Level Based on Photoplethysmography Using Time-Frequency Analysis
    Susana, Ernia
    Ramli, Kalamullah
    Purnamasari, Prima Dewi
    Apriantoro, Nursama Heru
    [J]. INFORMATION, 2023, 14 (03)
  • [10] Non-invasive method for blood glucose monitoring using ECG signal
    Arbi, Khadidja Fellah
    Soulimane, Sofiane
    Saffih, Faycal
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 1 - 9