Fast and precise voltage sag detection method for dynamic voltage restorer (DVR) application

被引:51
|
作者
Sadigh, A. Khoshkbar [1 ]
Smedley, K. M. [1 ]
机构
[1] Univ Calif Irvine, Elect Engn & Comp Sci Dept, Power Elect Lab, Irvine, CA 92617 USA
关键词
Dynamic voltage restorer; Voltage sag detection; Power quality; Signal detection; Digital signal processor (DSP); SAG/SWELL DETECTION METHOD; POWER QUALITY ANALYSIS; CONTROL SCHEME; PERFORMANCE EVALUATION; CLASSIFICATION; DISTURBANCES; MITIGATION; IMPLEMENTATION; SYSTEM; FILTER;
D O I
10.1016/j.epsr.2015.08.002
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Voltage sag detection method has a significant impact on the performance of dynamic voltage restorer (DVR). This paper proposes a fundamental voltage amplitude detection method which is applicable in both single/three-phase systems for DVR applications. Advantages of the proposed method include application in distorted power grid without any low-pass filter, precise and reliable detection, simple computation and implementation without using a phased locked loop and lookup table. The proposed method has been simulated and implemented experimentally and tested under various conditions considering all possible cases such as different amounts of voltage sag depth (VSD), different amounts of point-on-wave (POW) at which voltage sag occurs, harmonic distortion, line frequency variation, and phase jump (PJ). A detailed procedure to design the threshold band for comparator is presented. According to the achieved results and detailed analysis, maximum ripple of the calculated fundamental voltage amplitude is +/- 0.3% in normal condition of line frequency and +/- 1% in the case of +/- 1 Hz variation of 60 Hz line frequency. In addition, the error between the actual fundamental voltage amplitude and the calculated one is almost zero in normal condition of line frequency and maximum of +/- 0.25% in the case of line frequency variation with excessive-harmonic distortion. Furthermore, detection time (DT) of the proposed method is analyzed in detail for different amounts of VSD, POW and PJ. The best and worst detection time of the proposed method were measured 1 and 8.8 ms, respectively. Finally, the proposed method has been compared with other methods available in the literature. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:192 / 207
页数:16
相关论文
共 50 条
  • [1] OPTIMIZATION OF VOLTAGE SAG/SWELL USING DYNAMIC VOLTAGE RESTORER (DVR)
    Saxena, Ragini
    Kushwah, Manorma
    [J]. 2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 4046 - 4051
  • [2] Voltage sag detection technique for a dynamic voltage restorer
    Fitzer, C
    Barnes, M
    Green, P
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (01) : 203 - 212
  • [3] Voltage sag detection technique for a Dynamic Voltage Restorer
    Fitzer, C
    Barnes, M
    Green, P
    [J]. CONFERENCE RECORD OF THE 2002 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2002, : 917 - 924
  • [4] The Voltage Sag Mitigation Method Based on Hybrid SMES-BES Dynamic Voltage Restorer(DVR)
    Ding, Kai
    Li, Wei
    Hu, Pan
    Hu, Anping
    Tao, Yibin
    Zhuang, Jun
    Lu, Hong
    [J]. PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 545 - 549
  • [5] A waveform synthesis technique for voltage sag compensation using dynamic voltage restorer (DVR)
    Immanuel, Vijayan
    Yankanchi, Gurunath
    [J]. 2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 951 - +
  • [6] Fast sag/swell detection method for fuzzy logic controlled dynamic voltage restorer
    Teke, A.
    Bayindir, K.
    Tumay, M.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (01) : 1 - 12
  • [7] Effective Controller Design for the Dynamic Voltage Restorer (DVR) for Voltage Sag Mitigation in Distribution Utilities
    Xu, Lin
    Han, Yang
    [J]. ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2011, 78 (05): : 304 - 311
  • [8] Application of Dynamic Voltage Restorer in Microgrid for Voltage Sag/Swell Mitigation
    Gayatri, M. T. L.
    Parimi, Alivelu M.
    Kumar, A. V. Pavan
    [J]. 2015 IEEE POWER, COMMUNICATION AND INFORMATION TECHNOLOGY CONFERENCE (PCITC-2015), 2015, : 750 - 755
  • [9] Improvement of Dynamic Voltage Restorer (DVR) Using Proportional Integral (PI) Controller for Mitigation of Voltage Sag
    Hamza, A. H. A.
    El-Koliel, M. S.
    Ali, M. N.
    El-Eissawi, H.
    Hafez, M. M.
    [J]. ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (01): : 44 - 52
  • [10] Simulation of dynamic voltage restorer (DVR) to mitigate voltage sag during three-phase fault
    Pal, Rakeshwri
    Gupta, Sushma
    [J]. 2016 INTERNATIONAL CONFERENCE ON ELECTRICAL POWER AND ENERGY SYSTEMS (ICEPES), 2016, : 105 - 110