Evaluating the performance of commonly used gas analysers for methane eddy covariance flux measurements: the InGOS inter-comparison field experiment

被引:36
|
作者
Peltola, O. [1 ]
Hensen, A. [2 ]
Helfter, C. [3 ]
Marchesini, L. Belelli [4 ]
Bosveld, F. C. [5 ]
van den Bulk, W. C. M. [2 ]
Elbers, J. A. [6 ]
Haapanala, S. [1 ]
Holst, J. [7 ]
Laurila, T. [8 ]
Lindroth, A. [7 ]
Nemitz, E. [3 ]
Rockmann, T. [9 ]
Vermeulen, A. T. [2 ]
Mammarella, I. [1 ]
机构
[1] Univ Helsinki, Dept Phys, Helsinki, Finland
[2] Energy Res Ctr Netherlands, Petten, Netherlands
[3] Ctr Ecol & Hydrol, Edinburgh Res Stn, Penicuik, Midlothian, Scotland
[4] Vrije Univ Amsterdam, Dept Earth Sci, Amsterdam, Netherlands
[5] Royal Netherlands Meteorol Inst, NL-3730 AE De Bilt, Netherlands
[6] Alterra, Wageningen, Netherlands
[7] Lund Univ, Dept Phys Geog & Ecosyst Sci, Lund, Sweden
[8] Finnish Meteorol Inst, FIN-00101 Helsinki, Finland
[9] Univ Utrecht, Inst Marine & Atmospher Res Utrecht, Utrecht, Netherlands
基金
芬兰科学院;
关键词
WATER-VAPOR; MIXING-RATIO; WPL TERMS; PATH; CH4; ATTENUATION; ACCURACY; QUALITY; CO2;
D O I
10.5194/bg-11-3163-2014
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
The performance of eight fast-response methane (CH4) gas analysers suitable for eddy covariance flux measurements were tested at a grassland site near the Cabauw tall tower (Netherlands) during June 2012. The instruments were positioned close to each other in order to minimise the effect of varying turbulent conditions. The moderate CH4 fluxes observed at the location, of the order of 25 nmol m(-2) s(-1), provided a suitable signal for testing the instruments' performance. Generally, all analysers tested were able to quantify the concentration fluctuations at the frequency range relevant for turbulent exchange and were able to deliver high-quality data. The tested cavity ringdown spectrometer (CRDS) instruments from Picarro, models G2311-f and G1301-f, were superior to other CH4 analysers with respect to instrumental noise. As an open-path instrument susceptible to the effects of rain, the LI-COR LI-7700 achieved lower data coverage and also required larger density corrections; however, the system is especially useful for remote sites that are restricted in power availability. In this study the open-path LI-7700 results were compromised due to a data acquisition problem in our data-logging setup. Some of the older closed-path analysers tested do not measure H2O concentrations alongside CH4 (i.e. FMA1 and DLT-100 by Los Gatos Research) and this complicates data processing since the required corrections for dilution and spectroscopic interactions have to be based on external information. To overcome this issue, we used H2O mole fractions measured by other gas analysers, adjusted them with different methods and then applied them to correct the CH4 fluxes. Following this procedure we estimated a bias of the order of 0.1 g (CH4) m(-2) (8% of the measured mean flux) in the processed and corrected CH4 fluxes on a monthly scale due to missing H2O concentration measurements. Finally, cumulative CH4 fluxes over 14 days from three closed-path gas analysers, G2311-f (Picarro Inc.), FGGA (Los Gatos Research) and FMA2 (Los Gatos Research), which were measuring H2O concentrations in addition to CH4, agreed within 3% (355-367 mg (CH4) m(-2)) and were not clearly different from each other, whereas the other instruments derived total fluxes which showed small but distinct differences (+/- 10 %, 330-399 mg (CH4) m(-2)).
引用
收藏
页码:3163 / 3186
页数:24
相关论文
共 8 条
  • [1] Field intercomparison of four methane gas analyzers suitable for eddy covariance flux measurements
    Peltola, O.
    Mammarella, I.
    Haapanala, S.
    Burba, G.
    Vesala, T.
    [J]. BIOGEOSCIENCES, 2013, 10 (06) : 3749 - 3765
  • [2] Field comparison of disjunct and conventional eddy covariance techniques for trace gas flux measurements
    Rinne, J.
    Douffet, T.
    Prigent, Y.
    Durand, P.
    [J]. ENVIRONMENTAL POLLUTION, 2008, 152 (03) : 630 - 635
  • [3] Quality control of CarboEurope flux data -: Part 2:: Inter-comparison of eddy-covariance software
    Mauder, M.
    Foken, T.
    Clement, R.
    Elbers, J. A.
    Eugster, W.
    Gruenwald, T.
    Heusinkveld, B.
    Kolle, O.
    [J]. BIOGEOSCIENCES, 2008, 5 (02) : 451 - 462
  • [4] Inter-comparison of thermal measurements using ground-based sensors, UAV thermal cameras, and eddy covariance radiometers
    Torres-Rua, Alfonso
    Nieto, Hector
    Parry, Christopher
    Elarab, Manal
    Collatz, Wesley
    Coopmans, Calvin
    McKee, Lynn
    McKee, Mac
    Kustas, William
    [J]. AUTONOMOUS AIR AND GROUND SENSING SYSTEMS FOR AGRICULTURAL OPTIMIZATION AND PHENOTYPING III, 2018, 10664
  • [5] Gap-Filling Eddy Covariance Latent Heat Flux: Inter-Comparison of Four Machine Learning Model Predictions and Uncertainties in Forest Ecosystem
    Khan, Muhammad Sarfraz
    Jeon, Seung Bae
    Jeong, Myeong-Hun
    [J]. REMOTE SENSING, 2021, 13 (24)
  • [6] Comparative CO2 flux measurements by eddy covariance technique using open- and closed-path gas analysers over the equatorial Pacific Ocean
    Kondo, Fumiyoshi
    Tsukamoto, Osamu
    [J]. TELLUS SERIES B-CHEMICAL AND PHYSICAL METEOROLOGY, 2012, 64
  • [7] Ozone flux measurements over a scots pine forest using eddy covariance method:: performance evaluation and comparison with flux-profile method
    Keronen, P
    Reissell, A
    Rannik, Ü
    Pohja, T
    Siivola, E
    Hiltunen, V
    Hari, P
    Kulmala, M
    Vesala, T
    [J]. BOREAL ENVIRONMENT RESEARCH, 2003, 8 (04): : 425 - 443
  • [8] Measurements of hydrogen sulfide (H2S) using PTR-MS: calibration, humidity dependence, inter-comparison and results from field studies in an oil and gas production region
    Li, R.
    Warneke, C.
    Graus, M.
    Field, R.
    Geiger, F.
    Veres, P. R.
    Soltis, J.
    Li, S. -M.
    Murphy, S. M.
    Sweeney, C.
    Petron, G.
    Roberts, J. M.
    de Gouw, J.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (10) : 3597 - 3610