A Hydrogen Peroxide Sensor Based on Pt@Au Nanoparticles Loading to Polyethyleneimine Functionalized Carbon Nanotubes

被引:20
|
作者
Wang Wei-Wei [1 ]
Qiu Yu [1 ]
Zhang Shao-Peng [1 ]
Li Jia-Wei [1 ]
Lu Xiao-Quan [1 ]
Liu Xiu-Hui [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Seed-mediated growth; Polythyleneimine; Functionalized carbon nanotubes; Pt@Au nanoparticles; Modified electrode; Hydrogen peroxide; DIRECT ELECTROCHEMISTRY; GOLD NANOPARTICLES; COMPOSITE; PLATINUM; FILM; ELECTROCATALYSIS; HEMOGLOBIN; BIOSENSOR; H2O2; ELECTRODE;
D O I
10.1016/S1872-2040(14)60744-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel hydrogen peroxide sensor was fabricated by the seed-mediated growth method. Firstly, polyethyleneimine (PEI) functionalized multiwalled carbon nanotubes (MWNTs) were used as growth scaffold on a glass carbon electrode (GCE). Then, Au nanoparticles were uniformly electrodeposited as seeds. Finally, Pt nanoparticles (PtNPs) grew on Au PtNPs to form Pt@Au core-shell structure nanocomposite. A new type of electrochemical sensor based on Pt@Au/PEI-MWNTs nanocomposites for detection of hydrogen peroxide was then developed, and the designed Pt@Au/PEI-MWNTs/GCE was characterized by electrochemical methods and field emission scanning electron microscopy (FESEM). The differential pulse experiment results showed that the modified electrode exhibited excellent electrocatalytic activity towards the reduction of H2O2 with the wide linear range from 9.2x10(-8) to 1.3x10(-3) M. The correlation coefficient was 0.9994 and the detection limit was down to 3.1x10(-8) M at the signal-to-noise ratio of 3.
引用
收藏
页码:835 / 841
页数:7
相关论文
共 36 条
  • [1] A sensor based on the carbon nanotubes-ionic liquid composite for simultaneous determination of hydroquinone and catechol
    Bu, Caihong
    Liu, Xiuhui
    Zhang, Yijun
    Li, Li
    Zhou, Xibin
    Lu, Xiaoquan
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 88 (01) : 292 - 296
  • [2] Peroxide analysis in laundry detergents using liquid chromatography
    Effkemann, S
    Pinkernell, U
    Karst, U
    [J]. ANALYTICA CHIMICA ACTA, 1998, 363 (01) : 97 - 103
  • [3] A non-enzymatic hydrogen peroxide sensor based on poly(vinyl alcohol)-multiwalled carbon nanotubes-platinum nanoparticles hybrids modified glassy carbon electrode
    Fang, Yuxin
    Zhang, Di
    Qin, Xia
    Miao, Zhiying
    Takahashi, Shigehiro
    Anzai, Jun-ichi
    Chen, Qiang
    [J]. ELECTROCHIMICA ACTA, 2012, 70 : 266 - 271
  • [4] Platinum-decorated nanoporous gold leaf for methanol electrooxidation
    Ge, Xingbo
    Wang, Rongyue
    Liu, Pengpeng
    Ding, Yi
    [J]. CHEMISTRY OF MATERIALS, 2007, 19 (24) : 5827 - 5829
  • [5] A new amperometric nanostructured sensor for the analytical determination of hydrogen peroxide
    Guascito, M. R.
    Filippo, E.
    Malitesta, C.
    Manno, D.
    Serra, A.
    Turco, A.
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 24 (04): : 1057 - 1063
  • [6] Electrochemical oxidation of hydrogen peroxide at platinum electrodes. Part 1. An adsorption-controlled mechanism
    Hall, SB
    Khudaish, EA
    Hart, AL
    [J]. ELECTROCHIMICA ACTA, 1998, 43 (5-6) : 579 - 588
  • [7] Chemiluminescent flow sensor for H2O2 based on the decomposition of H2O2 catalyzed by cobalt(II)-ethanolamine complex immobilized on resin
    Hanaoka, S
    Lin, JM
    Yamada, M
    [J]. ANALYTICA CHIMICA ACTA, 2001, 426 (01) : 57 - 64
  • [8] A method to construct a third-generation horseradish peroxidase biosensor: Self-assembling gold nanoparticles to three-dimensional sol-gel network
    Jia, JB
    Wang, BQ
    Wu, AG
    Cheng, GJ
    Li, Z
    Dong, SJ
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (09) : 2217 - 2223
  • [9] Jiao Y Z, 2011, GUANGZHOU CHEM IND, V39, P14
  • [10] Fabrication of a novel nonenzymatic hydrogen peroxide sensor based on Se/Pt nanocomposites
    Li, Ye
    Zhang, Jing-Jing
    Xuan, Jie
    Jiang, Li-Ping
    Zhu, Jun-Jie
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (06) : 777 - 780