Tissue perfusion modelling in optical coherence tomography

被引:2
|
作者
Stohanzlova, Petra [1 ]
Kolar, Radim [1 ]
机构
[1] Brno Univ Technol, Fac Elect Engn & Commun, Dept Biomed Engn, Tech 12, Brno 61600, Czech Republic
关键词
Optical coherence tomography; Perfusion analysis; Deconvolution; Model; Phantom; Impulse response; BLOOD-BRAIN-BARRIER; NANOPARTICLES; TRANSPORT; DELIVERY;
D O I
10.1186/s12938-017-0320-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Optical coherence tomography (OCT) is a well established imaging technique with different applications in preclinical research and clinical practice. The main potential for its application lies in the possibility of noninvasively performing "optical biopsy". Nevertheless, functional OCT imaging is also developing, in which perfusion imaging is an important approach in tissue function study. In spite of its great potential in preclinical research, advanced perfusion imaging using OCT has not been studied. Perfusion analysis is based on administration of a contrast agent (nanoparticles in the case of OCT) into the bloodstream, where during time it specifically changes the image contrast. Through analysing the concentration-intensity curves we are then able to find out further information about the examined tissue. Methods: We have designed and manufactured a tissue mimicking phantom that provides the possibility of measuring dilution curves in OCT sequence with flow rates 200, 500, 1000 and 2000 mu L/min. The methodology comprised of using bolus of 50 mu L of gold nanorods as a contrast agent (with flow rate 5000 mu Lw/min) and continuous imaging by an OCT system. After data acquisition, dilution curves were extracted from OCT intensity images and were subjected to a deconvolution method using an input-output system description. The aim of this was to obtain impulse response characteristics for our model phantom within the tissue mimicking environment. Four mathematical tissue models were used and compared: exponential, gamma, lagged and LDRW. Results: We have shown that every model has a linearly dependent parameter on flow (R-2 values from 0.4914 to 0.9996). We have also shown that using different models can lead to a better understanding of the examined model or tissue. The lagged model surpassed other models in terms of the minimisation criterion and R-2 value. Conclusions: We used a tissue mimicking phantom in our study and showed that OCT can be used for advanced perfusion analysis using mathematical model and deconvolution approach. The lagged model with three parameters is the most appropriate model. Nevertheless, further research have to be performed, particularly with real tissue.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Tissue perfusion modelling in optical coherence tomography
    Petra Stohanzlova
    Radim Kolar
    [J]. BioMedical Engineering OnLine, 16
  • [2] Continuous monitoring of tissue growth inside a perfusion bioreactor by optical coherence tomography
    Bagnaninchi, P. O.
    El Haj, A.
    Yang, Y.
    [J]. OPTICS IN TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2007, 6439
  • [3] Doppler optical coherence tomography to monitor the effect of photodynamic therapy on tissue morphology and perfusion
    Aalders, Maurice C. G.
    Triesscheijn, Martijn
    Ruevekamp, Marjan
    de Bruin, Martijn
    Baas, Paul
    Faber, Dirk J.
    Stewart, Fiona A.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (04)
  • [4] Advanced modelling of optical coherence tomography systems
    Andersen, PE
    Thrane, L
    Yura, HT
    Tycho, A
    Jorgensen, TM
    Frosz, MH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (07): : 1307 - 1327
  • [5] Single fiber perfusion phantom for optical coherence tomography
    Podlipna, Petra
    Kolar, Radim
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES VI, 2013, 8802
  • [6] Choroidal perfusion measurements made with optical coherence tomography
    Wu, FI
    Glucksberg, MR
    [J]. APPLIED OPTICS, 2005, 44 (08) : 1426 - 1433
  • [7] Measurment of retinal perfusion using optical coherence tomography
    Glucksberg, M
    Wu, FI
    Walsh, JT
    [J]. FASEB JOURNAL, 2003, 17 (04): : A125 - A126
  • [8] Gap in Capillary Perfusion on Optical Coherence Tomography Angiography
    Huang, Wenbin
    Sha, Xiangyin
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (07) : 3044 - 3044
  • [9] Determining tissue optical properties by optical coherence tomography
    Wang, Kai
    Ding, Zhihua
    Wang, Ling
    [J]. FIFTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, PTS 1 AND 2, 2007, 6534
  • [10] Optical coherence elastography: Strain imaging in tissue using optical coherence tomography
    Kennedy, Brendan F.
    Kennedy, Kelsey M.
    Ford, Chris
    McLaughlin, Robert A.
    Bush, Mark B.
    Sampson, David D.
    [J]. 22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421