Research on the reliability of capacitor voltage transformers calibration results

被引:15
|
作者
Meng, Zhan [1 ]
Li, Hongbin [1 ]
Zhang, Chuanji [1 ]
Chen, Mianzhou [1 ]
Chen, Qing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, Wuhan, Hubei, Peoples R China
关键词
Capacitor voltage transformers (CVTs); Measurement error; Calibration result; Electric field interference; Secondary load; ERROR;
D O I
10.1016/j.measurement.2019.07.011
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The capacitor voltage transformer (CVT) is one of the most important measurement equipment in the power system, and its measurement accuracy is a key factor to ensure the safety of the power system and the fairness of electricity trade. To ensure the steady-state measurement accuracy, the conventional calibration is carried out to CVTs before operating in substations, and the operating CVTs must be calibrated periodically. However, excessive measurement error often occurs to CVTs which have passed the calibrations. In this paper, the reasons for the inconsistency between calibration results and actual measurement errors are proposed. The calibration in the laboratory, on-site calibration and three-phase operating CVTs are simulated according to actual operating conditions. Both the theoretical analysis and simulation results demonstrate that significant differences exist between the actual measurement errors and the calibration results of CVTs. Some experiments corresponding to the simulations verify the conclusions above. Finally, some suggestions to improve the reliability of calibration results are given. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:770 / 779
页数:10
相关论文
共 50 条
  • [1] Reliability centered maintenance for capacitor voltage transformers
    Morais, Diego R.
    Rolim, Jacqueline G.
    Coser, Joni
    Zuern, Hans H.
    [J]. 2006 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, VOLS 1 AND 2, 2006, : 573 - 578
  • [2] A SIMPLIFIED SYSTEM FOR CALIBRATION OF COUPLING CAPACITOR VOLTAGE TRANSFORMERS
    HILLHOUSE, DL
    PETERSONS, O
    SZE, WC
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (05): : 1092 - 1098
  • [3] Research into an Online Calibration System for the Errors of Voltage Transformers Based on Open-Closed Capacitor
    Li, Zhenhua
    Li, Qiuhui
    Wu, Zhengtian
    Li, Zhenxing
    [J]. ENERGIES, 2018, 11 (06)
  • [4] PROTOTYPE SYSTEM FOR ON-SITE CALIBRATION OF COUPLING CAPACITOR VOLTAGE TRANSFORMERS (CCVTS)
    HILLHOUSE, DL
    PETERSONS, O
    SZE, WC
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (03): : 1026 - 1036
  • [5] An accurate on-site calibration system for electronic voltage transformers using a standard capacitor
    Hu, Chen
    Chen, Mian-zhou
    Li, Hong-bin
    Zhang, Zhu
    Jiao, Yang
    Shao, Haiming
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (05)
  • [6] Ferroresonance evaluation on capacitor voltage transformers
    Paulo Henrique Barbosa de Souza Pinheiro
    Maryana Lopes Correa Vidal
    Felipe Franco da Rocha
    Bruno Wanderley França
    Márcio Zamboti Fortes
    [J]. Electrical Engineering, 2020, 102 : 1775 - 1783
  • [7] Ferroresonance evaluation on capacitor voltage transformers
    Barbosa de Souza Pinheiro, Paulo Henrique
    Correa Vidal, Maryana Lopes
    da Rocha, Felipe Franco
    Franca, Bruno Wanderley
    Fortes, Marcio Zamboti
    [J]. ELECTRICAL ENGINEERING, 2020, 102 (03) : 1775 - 1783
  • [8] FERRORESONANT OSCILLATIONS IN CAPACITOR VOLTAGE TRANSFORMERS
    CHAKRAVARTHY, SK
    NAYAR, CV
    [J]. IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 1995, 142 (01): : 30 - 36
  • [9] Calibration of high voltage transformers
    Jones, RG
    [J]. 1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 207 - 208
  • [10] Research on the Calibration Instrument for the Medium-voltage Electronic Instrument Transformers
    Yue, Xie
    Jing, Chen
    [J]. MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 7471 - +