False-Positive Results of Serological Tests for Allergy in Alcoholic Patients

被引:7
|
作者
Alvela-Suarez, L. [1 ,4 ]
Campos, J. [1 ]
Carballo, I [1 ]
Gomez-Rial, J. [2 ]
Vidal, C. [3 ]
Lombardero, M. [5 ]
Linneberg, A. [6 ,7 ]
Gonzalez-Quintela, A. [1 ]
机构
[1] Univ Santiago de Compostela, Dept Internal Med, Complejo Hosp, Santiago De Compostela, Spain
[2] Univ Santiago de Compostela, Dept Immunol, Santiago De Compostela, Spain
[3] Univ Santiago de Compostela, Dept Allergy, Complejo Hosp, Santiago De Compostela, Spain
[4] HM Hosp La Rosaleda, Santiago De Compostela, Spain
[5] ALK Abello SA, CMC R&D Dept, Madrid, Spain
[6] Rigshosp, Res Ctr Prevent & Hlth, Glostrup, Denmark
[7] Univ Copenhagen, Dept Clin Med, Fac Hlth & Med Sci, Copenhagen, Denmark
关键词
Alcohol; Cross-reactive carbohydrate determinants; Allergy; Glycans; Specific IgE; Total IgE; REACTIVE CARBOHYDRATE DETERMINANTS; IMMUNOGLOBULIN-E SENSITIZATION; SERUM IGE; THE-159C/T POLYMORPHISM; CLINICAL-RELEVANCE; PROMOTER REGION; VENOM ALLERGEN; LIVER-DISEASE; INSECT CELLS; CD14; GENE;
D O I
10.18176/jiaci.0309
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Alcohol consumption is associated with enhanced T(H)2 immune responses. Objective: To investigate the frequency of false-positive results in serological tests for allergy in alcoholic patients. Methods: A total of 138 alcoholic patients consecutively admitted to hospital underwent a panel of allergy tests that included serum total IgE, a multiallergen IgE test (UniCAP Phadiatop), and skin prick tests to relevant aeroallergens in the area, which were considered the standard reference for atopy. In selected cases with positive specific IgE (sIgE) to cross-reactive carbohydrate determinants (CCDs) on ImmunoCAP, we determined sIgE to hymenoptera venom components (ADVIA Centaur) and a microarray of 103 allergen components (ISAC). Results: Increased serum total IgE (>170 IU/mL) was observed in 59/110 (54%) of nonatopic (skin prick test-negative) patients. The result of the multiallergen IgE test was positive in 46 nonatopic patients (42%). This finding was closely associated with high serum concentrations of total IgE and sIgE to CCDs. The vast majority of patients with positive CCD-sIgE showed positivity to glycosylated plant and hymenoptera allergen components on ISAC and ADVIA Centaur. Only 1 out of 26 patients with positive sIgE to CCD and hymenoptera venom developed honeybee venom allergy after a median follow-up of 166 months. Correlations between measurements of sIgE to CCD markers on ImmunoCAP, ADVIA Centaur, and ISAC were imperfect. Conclusions: Serological tests for allergy should be interpreted with caution in alcoholic patients, who frequently have increased levels of total IgE and CCD-sIgE and subsequent positivity of sIgE to glycosylated allergen components, irrespective of the method used.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 50 条
  • [1] False-positive serological tests in malaria
    Tsi, L
    Beltrán, B
    Restoy, EG
    Pérez, P
    [J]. MEDICINA CLINICA, 2003, 120 (18): : 718 - 719
  • [2] FALSE-POSITIVE SEROLOGICAL TESTS FOR SYPHILIS IN PREGNANCY
    SALO, OP
    AHO, K
    NIEMINEN, E
    HORMILA, P
    [J]. ACTA DERMATO-VENEREOLOGICA, 1969, 49 (03) : 332 - &
  • [3] False-positive serological tests in acute malaria
    Ghosh, K
    Javeri, KN
    Mohanty, D
    Parmar, BD
    Surati, RR
    Joshi, SH
    [J]. BRITISH JOURNAL OF BIOMEDICAL SCIENCE, 2001, 58 (01) : 20 - 23
  • [4] MALIGNANCIES AND FALSE-POSITIVE SEROLOGICAL RESULTS FOR HYDATIDOSIS
    MANSUETO, S
    MIGNECO, G
    LACASCIA, C
    MICELI, MD
    [J]. BRITISH MEDICAL JOURNAL, 1980, 281 (6250): : 1284 - 1284
  • [5] FALSE-POSITIVE RESULTS OF MANTOUX TESTS
    MELLOR, J
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 1985, 132 (12) : 1403 - 1403
  • [6] FOLLOW-UP OF CARRIERS OF BIOLOGICAL FALSE-POSITIVE RESULTS OF SEROLOGICAL TESTS FOR SYPHILIS
    SHINSKY, GE
    PROTOPOPOVA, NE
    NIKITINA, LS
    YUMINOVA, VV
    KONENKOVA, VP
    SARANTSEVA, NM
    [J]. KLINICHESKAYA MEDITSINA, 1991, 69 (04): : 75 - 78
  • [7] FALSE-POSITIVE SEROLOGICAL TESTS IN HEART-TRANSPLANT RECIPIENTS
    NAOT, Y
    LUFT, BJ
    REMINGTON, JS
    [J]. LANCET, 1981, 2 (8246): : 590 - 591
  • [8] ESSENTIAL MIXED CRYOGLOBULINEMIA WITH FALSE-POSITIVE SEROLOGICAL TESTS FOR SYPHILIS
    JONES, RR
    PUSEY, C
    SCHIFFERLI, J
    JOHNSTON, NA
    [J]. BRITISH JOURNAL OF VENEREAL DISEASES, 1983, 59 (01): : 33 - 36
  • [9] FALSE-POSITIVE CARDIO-LIPID AND FTA SEROLOGICAL TESTS IN PATIENTS WITH ANTINUCLEAR ANTIBODIES
    SEPETJIAN, M
    MONIER, JC
    THIVOLET, J
    TISSOTGUERRAZ, F
    SALUSSOLA, D
    [J]. PATHOLOGIE BIOLOGIE, 1976, 24 (06): : 397 - 400
  • [10] False-positive pregnancy tests in patients with enterocystoplasties
    Nethercliffe, J
    Trewick, A
    Samuell, C
    Leaver, R
    Woodhouse, CRJ
    [J]. BJU INTERNATIONAL, 2001, 87 (09) : 780 - 782