Determination of biochemical parameters in human serum by near-infrared spectroscopy

被引:15
|
作者
Garcia-Garcia, J. L. [1 ]
Perez-Guaita, D. [1 ]
Ventura-Gayete, J. [2 ]
Garrigues, S. [1 ]
de la Guardia, M. [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
[2] Univ Hosp Doctor Peset, Valencia 46017, Spain
关键词
LEAST-SQUARES REGRESSION; GAMMA-GLOBULIN; GLUCOSE; CHOLESTEROL; CHEMISTRY; ALBUMIN; SYSTEM; UREA; TOOL;
D O I
10.1039/c3ay42198h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
NIR offers multiple advantages for serum analysis, permitting a fast and direct determination of several parameters simultaneously, with low sample handling and without the need for reagents during the measurement step. The aim of this paper was to provide an evaluation of this technique in a real world scale, for the simultaneous determination of several parameters and based on a considerable number of samples. Direct near infrared (NIR) absorbance measurements were used to determine the concentration of clinical parameters in human serum that are required in routine biochemical tests. Total protein, albumin, total cholesterol, high-density lipoprotein (HDL cholesterol), low-density lipoprotein (LDL cholesterol), and very low-density lipoprotein (VLDL cholesterol), triglycerides, urea and glucose were determined in 447 serum samples obtained randomly from the clinical laboratory of the University Hospital Doctor Peset in Valencia (Spain). NIR spectra from 12 500 to 4000 cm(-1) obtained with a 1 mm optical path length were evaluated by using partial least squares regression models (PLS) built from the spectra of samples with known concentrations provided by the hospital. Root mean square error cross-validation (RMSECV) was used for selecting a number of factors, spectral regions and spectral preprocessing considered to build the models, that were evaluated from their prediction capability using the relative root mean square error of prediction (RRMSEP) of a series of around 30 independent samples, not used for calibration. For some analytes such as total protein, albumin, total cholesterol and triglycerides, errors obtained were 2.3, 4.4, 5.1, and 6.2% respectively, evidencing that the proposed methodology could compete with the enzymatic reference methodologies. However in the case of urea, glucose, HDL and LDL, average errors obtained were 16.0, 16.2, 18.0 and 11.0% respectively, and therefore the NIR methodology proposed is limited as a screening tool. With the use of a considerable number of samples for calibration, this study confirms that the proposed green and cost-effective methodology is ready for scaling up from the bench to the real world.
引用
收藏
页码:3982 / 3989
页数:8
相关论文
共 50 条
  • [1] Wavelength selection for the determination of glucose in human serum by near-infrared spectroscopy
    Ding, Q
    Small, GW
    FOURIER TRANSFORM SPECTROSCOPY, 1998, (430): : 264 - 267
  • [2] Near-Infrared Spectroscopy for Mapping of Human Meniscus Biochemical Constituents
    Juho Ala-Myllymäki
    Tommi Paakkonen
    Antti Joukainen
    Heikki Kröger
    Petri Lehenkari
    Juha Töyräs
    Isaac O. Afara
    Annals of Biomedical Engineering, 2021, 49 : 469 - 476
  • [3] Near-Infrared Spectroscopy for Mapping of Human Meniscus Biochemical Constituents
    Ala-Myllymaki, Juho
    Paakkonen, Tommi
    Joukainen, Antti
    Kroger, Heikki
    Lehenkari, Petri
    Toyras, Juha
    Afara, Isaac O.
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (01) : 469 - 476
  • [4] Quantitative determination of serum LDL cholesterol by near-infrared spectroscopy
    Liu, KZ
    Shi, MH
    Man, A
    Dembinski, TC
    Shaw, RA
    VIBRATIONAL SPECTROSCOPY, 2005, 38 (1-2) : 203 - 208
  • [5] Determination of polarimetric parameters of honey by near-infrared transflectance spectroscopy
    García-Alvarez, M
    Ceresuela, S
    Huidobro, JF
    Hermida, M
    Rodríguez-Otero, JL
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (03) : 419 - 425
  • [6] Determination of Compatibility Parameters of Crude Oils by Near-Infrared Spectroscopy
    Rogel, Estrella
    Lee, Eddy
    Hench, Kyle
    Miao, Toni
    Rudenko, Joanna
    ENERGY & FUELS, 2024, 38 (17) : 16049 - 16055
  • [7] Determination of Proteins in Human Serum by Near-Infrared Spectroscopy with Partial Least Square Analysis
    Guo, Huixian
    Huang, Furong
    Li, Yuanpeng
    Fang, Tao
    Zhu, Siqi
    Chen, Zhenqiang
    ANALYTICAL LETTERS, 2016, 49 (18) : 2964 - 2976
  • [8] Near-Infrared Spectroscopy for Determination of the Biochemical Methane Potential: State of the Art
    Ward, Alastair J.
    CHEMICAL ENGINEERING & TECHNOLOGY, 2016, 39 (04) : 611 - 619
  • [9] Near-infrared Raman spectroscopy of human whole blood and serum
    Berger, AJ
    Itzkan, I
    Feld, MS
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS AND ADVANCED TECHNIQUES IN ANALYTICAL CYTOLOGY, PROCEEDINGS OF, 1997, 2982 : 87 - 90
  • [10] DETERMINATION OF FILM-COATED TABLET PARAMETERS BY NEAR-INFRARED SPECTROSCOPY
    KIRSCH, JD
    DRENNEN, JK
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (10) : 1273 - 1281