Clean intermittent self-catheterization in persons with multiple sclerosis: the influence of cognitive dysfunction

被引:36
|
作者
Vahter, L. [1 ,2 ]
Zopp, I. [1 ]
Kreegipuu, M. [3 ]
Kool, P. [4 ]
Talvik, T. [4 ,5 ]
Gross-Paju, K. [1 ]
机构
[1] Tallinn Univ, W Tallinn Cent Hosp, Estonian MS Ctr, EE-10617 Tallinn, Estonia
[2] Tallinn Univ, Inst Psychol, EE-10617 Tallinn, Estonia
[3] Univ Tartu, Inst Psychol, EE-50090 Tartu, Estonia
[4] Univ Tartu, Dept Paediat, EE-50090 Tartu, Estonia
[5] Univ Tartu, Hosp Childrens Clin, Neurol Unit, EE-50090 Tartu, Estonia
关键词
bladder management; clean intermittent self-catheterization; cognitive dysfunction; multiple sclerosis; rehabilitation; IMPAIRMENT; MANAGEMENT;
D O I
10.1177/1352458508098599
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Bladder problems are very common in persons with multiple sclerosis (PwMS). Objective The aim of this study was to investigate the ability of PwMS to learn clean intermittent self-catheterization (CISC). Methods The physical disability of 23 PwMS was evaluated with the Expanded Disability Status Scale (EDSS), and cognitive status was evaluated with the Brief Repeatable Battery of Neuropsychological Tests (BRB-N). CISC was taught by the same continence advisor who was blinded to the cognitive test results. The ability to learn CISC was evaluated immediately after sessions and 3 months later. Twenty-three consecutive PwMS participated in the study. Results In all, 87% (20/23) of the PwMS successfully finished CISC training. The number of lessons needed to acquire CISC skills differed significantly depending on the EDSS (Spearman r = 0.682, P = 0.0003), but the total cognitive decline subscore did not influence the ability to learn CISC. Only 13% (3/23) of the PwMS failed to learn CISC. The ability to learn CISC depended on the number of lessons needed to acquire CISC (r = -0.499, P = 0.0313) and the EDSS score (r = -0.433, P = 0.0390) but not on the course of the disease (r = 0.125, P = 0.5696) or on cognitive decline (r = -0.311, P = 0.1480). After 3 months of follow-up, 30% (6/20) of the PwMS had ceased performing CISC. A follow-up indicated no statistically significant correlations among any of the subscores of the cognitive test battery, the EDSS score, the course of the disease, and the time required to learn CISC and effective bladder management. Conclusions Our study thus confirmed that most (87%) PwMS were able to learn CISC in spite of cognitive dysfunction and therefore to improve their quality of life. Multiple Sclerosis 2009; 15: 379-384. http://msj.sagepub.com
引用
收藏
页码:379 / 384
页数:6
相关论文
共 50 条
  • [1] Multiple sclerosis and intermittent self-catheterization
    Jacq, C.
    Hubeaux, K.
    Ramanantsitonta, J.
    PROGRES EN UROLOGIE, 2021, 31 (04): : 195 - 203
  • [2] CLEAN INTERMITTENT SELF-CATHETERIZATION
    JORGENSEN, A
    JUHL, B
    KRARUP, T
    WALTER, S
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1994, : 97 - 99
  • [3] Adherence to Anticholinergic Therapy and Clean Intermittent Self-Catheterization in Patients With Multiple Sclerosis
    Motavasseli, Damien
    Chesnel, Camille
    Charlanes, Audrey
    Menoux, Diane
    Charoenwong, Francis
    Le Breton, Frederique
    Amarenco, Gerard
    INTERNATIONAL NEUROUROLOGY JOURNAL, 2018, 22 (02) : 133 - 141
  • [4] REFLUX AND CLEAN INTERMITTENT SELF-CATHETERIZATION
    KASS, EJ
    UROLOGY, 1984, 23 (05) : 529 - 529
  • [5] CLEAN INTERMITTENT SELF-CATHETERIZATION IN THE ELDERLY
    WHITELAW, S
    HAMMONDS, JC
    TREGELLAS, R
    BRITISH JOURNAL OF UROLOGY, 1987, 60 (02): : 125 - 127
  • [6] CLEAN INTERMITTENT SELF-CATHETERIZATION IN THE ELDERLY
    BENNETT, CJ
    DIOKNO, AC
    UROLOGY, 1984, 24 (01) : 43 - 45
  • [7] Prescribe clean intermittent self-catheterization
    Bonniaud, Veronique
    Leroy, Joel
    Kleinclauss, Francois
    Look, Pierre-Yves
    Bevalot, Julien
    Parratte, Bernard
    PRESSE MEDICALE, 2009, 38 (03): : 392 - 396
  • [8] CLEAN TECHNIQUE FOR INTERMITTENT SELF-CATHETERIZATION
    CHAMPION, VL
    NURSING RESEARCH, 1976, 25 (01) : 13 - 18
  • [9] A guide to female clean intermittent self-catheterization
    Zhang, L.
    Thompson, D.
    Arya, L. A.
    Khanijow, K. D.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2018, 218 (02) : S962 - S962
  • [10] CLEAN INTERMITTENT SELF-CATHETERIZATION IN 172 ADULTS
    WEBB, RJ
    LAWSON, AL
    NEAL, DE
    BRITISH JOURNAL OF UROLOGY, 1990, 65 (01): : 20 - 23