Optimization of chemical cleaning of a reverse osmosis membrane from a desalination plant by means of two-step static tests

被引:4
|
作者
Garcia-Fayos, B. [1 ]
Arnal, J. M. [1 ]
Gimenez, A. [1 ]
Alvarez-Blanco, S. [1 ]
Sancho, M. [1 ]
机构
[1] Univ Politecn Valencia, Inst Ind Radiophys & Environm Safety ISIRYM, Valencia 46022, Spain
关键词
Chemical agent; Multi-step cleaning; RO; Static test; RO MEMBRANE; WATER;
D O I
10.1080/19443994.2014.959738
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Research in cleaning procedures of reverse osmosis membranes used in seawater desalination to minimize costs and achieve high efficiency is necessary. Multi-step cleaning can represent a useful tool, since the cleaning efficiency can be improved by means of utilization of different chemicals with complementary cleaning mechanisms. The objective of this work was the optimization of a two-step cleaning procedure to recover the membrane properties and reduce power costs. Spent Hydranautics SWC3 membranes (USA) were supplied by a desalination plant. Cleaning tests were performed in three stages: one-step static cleaning, two-step static cleaning and characterization of the membrane surface after the cleaning process. Four cleaning agents at two different concentrations were used. All possible combinations of them were considered, including sequence effect. After the cleaning process, membrane surface was characterized by field emission scanning electron microscopy coupled with energy dispersive X-ray spectroscopy and atomic force microscopy. One-step static cleaning test indicated that sodium dodecyl sulphate 1% w/v was the most efficient cleaning solution, followed by NaOH 2% w/v. Two-step cleaning tests showed that the procedure that maximized permeate flux recovery was surfactant-alkaline cleaning, whereas the one that maximized the recovery of the salt rejection index was alkaline-acid sequence. Characterization of the membrane surface after the cleaning steps confirmed that fouling deposits were significantly removed.
引用
收藏
页码:3367 / 3379
页数:13
相关论文
共 20 条
  • [1] Two-Step Optimization of Pressure and Recovery of Reverse Osmosis Desalination Process
    Liang, Shuang
    Liu, Cui
    Song, Lianfa
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (09) : 3272 - 3277
  • [2] Chemical elements of brine discharge from operational Tajoura reverse osmosis desalination plant
    Brika, Bashir
    Omran, Abdul Aziz
    Addien, Obiyda Dia
    [J]. DESALINATION AND WATER TREATMENT, 2016, 57 (12) : 5345 - 5349
  • [3] Sequential effects of cleaning protocols on desorption of reverse osmosis membrane foulants: Autopsy results from a full-scale desalination plant
    Lee, Yong-Gu
    Kim, Sangwon
    Shin, Jaegwan
    Rho, Hojung
    Kim, Young Mi
    Cho, Kyung Hwa
    Eom, Heonseop
    Oh, Sang-Eun
    Cho, Jaeweon
    Chon, Kangmin
    [J]. DESALINATION, 2021, 500
  • [4] Statistical optimization of chemical cleaning conditions of reverse osmosis membrane process in forward osmosis testing set-up
    Fagkaew, Pattarasiri
    Yun, Yeo-Myeong
    Kim, Hyojeon
    Kang, Seoktae
    [J]. DESALINATION AND WATER TREATMENT, 2018, 110 : 19 - 26
  • [5] Structural and chemical characterization of long-term reverse osmosis membrane fouling in a full scale desalination plant
    Melian-Martel, N.
    Sadhwani, J. J.
    Malamis, S.
    Ochsenkuehn-Petropoulou, M.
    [J]. DESALINATION, 2012, 305 : 44 - 53
  • [6] Comparison of membrane fouling and cleaning in one-pass reverse osmosis and two-pass nanofiltration approaches to seawater desalination
    Tanuwidjaja, Dian
    Jin, Xue
    Huang, Xiaofei
    Marambio-Jones, Catalina
    Jawor, Anna
    Zhang, Minglu
    Jiang, Sunny
    Cheng, Robert
    Hoek, Eric M., V
    [J]. DESALINATION AND WATER TREATMENT, 2020, 193 : 235 - 250
  • [7] Synthesis, characterization and excellent antibacterial property of cellulose acetate reverse osmosis membrane via a two-step reaction
    Li, Fu
    Fei, Pengfei
    Cheng, Bowen
    Meng, Jianqiang
    Liao, Liang
    [J]. CARBOHYDRATE POLYMERS, 2019, 216 : 312 - 321
  • [8] Evaluation of maintenance chemical cleaning in seawater reverse osmosis pilot plant using hot wastewater from power plant
    Park, Ki Tae
    Park, JunYoung
    Kim, Minjin
    Kim, Hyung Soo
    Kim, Poo Reum
    Kim, Ji-Hoon
    [J]. DESALINATION AND WATER TREATMENT, 2019, 141 : 1 - 7
  • [9] Characterization of fouling for a full-scale seawater reverse osmosis plant on the Mediterranean sea: membrane autopsy and chemical cleaning efficiency
    Adel, Mahmoud
    Nada, Tarek
    Amin, Sherif
    Anwar, Tohamy
    Mohamed, Ashraf A.
    [J]. GROUNDWATER FOR SUSTAINABLE DEVELOPMENT, 2022, 16
  • [10] Ion-exchange membrane electrodialytic salt production using brine discharged from a reverse osmosis seawater desalination plant
    Tanaka, Y
    Ehara, R
    Itoi, S
    Goto, T
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2003, 222 (1-2) : 71 - 86