WSB-A fluoroscopy C-arm communication strategy

被引:12
|
作者
Williams, Timothy H. D. [1 ]
Syrett, Amanda G. [2 ]
Brammar, Timothy J. [2 ]
机构
[1] April Cottage, Tostock IP30 9PN, Suffolk, England
[2] Ipswich Hosp NHS Trust, Ipswich, Suffolk, England
关键词
C-arm; Fluoroscopy; Communication; Radiation; Radiographer; Theatre; Language; Scientific; Intramedullary nail; OPERATING-ROOM; TEAMWORK;
D O I
10.1016/j.injury.2008.10.011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Good communication between an operating clinician and the attending radiographer when using C-arm fluoroscopy is vital. Efficient and safe use of ionising radiation protects all theatre staff. The object of this study was to design and test a single communication language for use in all fluoroscopy-assisted procedures. Method: A clinician guiding a radiographer performed a control 'no-rules' experiment of 56 targeting manoeuvres with a fluoroscopic C-arm on a scientific model. A single beam laser replaced the usual ionising radiation beam. The time taken for each targeting along with the laser exposure required was recorded. Following a period of instruction, the experiment was repeated using only our pre-defined communication strategy. The data was collected for statistical analysis. Results: A statistically significant reduction was seen in the time taken for each targeting manoeuvre and the laser exposure required when using our strategy. Conclusion: This study shows that using our pre-prepared communication strategy could significantly improve efficiency and safety of fluoroscopic C-arm use. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:840 / 843
页数:4
相关论文
共 50 条
  • [1] C-ARM FLUOROSCOPY
    COHEN, MD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) : 646 - 647
  • [2] C-ARM FLUOROSCOPY - REPLY
    DAVIS, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) : 647 - 647
  • [3] Use of Standardized Language for C-arm Fluoroscopy Improves Intraoperative Communication and Efficiency
    Burke, John F.
    Anciano, Victor
    Novicoff, Wendy M.
    Yarboro, Seth R.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (09) : E458 - E464
  • [4] Hysterosalpingography with use of mobile C-arm fluoroscopy
    Phillips, Jordana
    Cochavi, Saadia
    Silberzweig, James E.
    [J]. FERTILITY AND STERILITY, 2010, 93 (06) : 2065 - 2068
  • [5] C-arm fluoroscopy in orthopaedic surgical practice
    Ojodu I.
    Ogunsemoyin A.
    Hopp S.
    Pohlemann T.
    Ige O.
    Akinola O.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (8) : 1563 - 1568
  • [6] Needle targeting under C-arm fluoroscopy servoing
    Mihaescu, C
    Ibanez, L
    Mocanu, M
    Cleary, K
    [J]. MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 888 - 897
  • [7] Sterility of C-arm fluoroscopy during spinal surgery
    Biswas, Debdut
    Bible, Jesse E.
    Whang, Peter G.
    Simpson, Andrew K.
    Grauer, Jonathan N.
    [J]. SPINE, 2008, 33 (17) : 1913 - 1917
  • [8] Utility of Intraoperative C-Arm Fluoroscopy for Frontal Sinusotomy
    Lee, Seung-Sin
    [J]. EWHA MEDICAL JOURNAL, 2009, 32 (02): : 61 - 64
  • [9] Intraoperative assessment of hindfoot alignment using C-arm fluoroscopy
    Park, Young Uk
    Lee, Jong Wha
    Chung, Jun Young
    Choi, Wan-Sun
    Kim, Taehun
    Seo, Young Wook
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (05) : 1248 - 1254
  • [10] Seed segmentation in C-arm fluoroscopy for brachytherapy implant reconstruction
    Vikal, S.
    Jain, A.
    Deguet, A.
    Song, D.
    Fichtinger, G.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2229 - 2229