Osteolysis After Unidirectional and Multidirectional Mobile-Bearing Total Knee Arthroplasty in Young Patients

被引:5
|
作者
Kim, Young-Hoo [1 ]
Kim, Jun-Shik [1 ]
Choi, Yoowang [1 ]
机构
[1] Ewha Womans Univ, Sch Med, Ctr Joint Replacement Korea, Seoul 110783, South Korea
来源
JOURNAL OF ARTHROPLASTY | 2009年 / 24卷 / 04期
关键词
osteolysis; polyethylene wear; uni- and multidirectional TKA; ANTERIOR-POSTERIOR-GLIDE; POLYETHYLENE WEAR; MENISCAL BEARING; FOLLOW-UP; REPLACEMENT; PROSTHESIS; KINEMATICS; DESIGN; MOTION; RANGE;
D O I
10.1016/j.arth.2008.02.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We questioned whether a difference exists between Multidirectional and unidirectional mobile-bearing total knee arthroplasties in terms of clinical results and the prevalence of polyethylene wear and periprosthetic osteolysis. We Studied 62 patients who underwent simultaneous bilateral total knee arthroplasties, with a unidirectional prosthesis implanted in 1 knee and a multidirectional one in the other. of the patients, 9 were men and 53 were women, with a mean age of 57.6 years (35-60 years). The minimum follow-up was 11 years (mean, 11.8 years; range, 11-13 years). Preoperative and postoperative knee and functional scores were not different between the 2 groups. No knee in either group had detectable tibial polyethylene liner wear or osteolysis on radiographs or on computed tomography scans. Two (3%) knees in each group were revised.
引用
收藏
页码:586 / 593
页数:8
相关论文
共 50 条
  • [1] Osteolysis in failed total knee arthroplasty: A comparison of mobile-bearing and fixed-bearing knees
    Huang, CH
    Ma, HM
    Liau, JJ
    Ho, FY
    Cheng, CK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (12): : 2224 - 2229
  • [2] Prevalence of Osteolysis After Simultaneous Bilateral Fixed- and Mobile-Bearing Total Knee Arthroplasties in Young Patients
    Kim, Young-Hoo
    Kim, Jun-Shik
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (06): : 932 - 940
  • [3] Fixed or mobile-bearing total knee arthroplasty
    Huang C.-H.
    Liau J.-J.
    Cheng C.-K.
    [J]. Journal of Orthopaedic Surgery and Research, 2 (1)
  • [4] Frontal plane kinematics after mobile-bearing total knee arthroplasty
    Stiehl, JB
    Komistek, RD
    Haas, B
    Dennis, DA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 56 - 61
  • [5] Early instability with mobile-bearing total knee arthroplasty
    Ridgeway, S
    Moskal, JT
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (06): : 686 - 693
  • [6] Modular, mobile-bearing hinge total knee arthroplasty
    Jones, RE
    Barrack, RL
    Skedros, J
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 306 - 314
  • [7] Early mechanical complications of a multidirectional mobile-bearing total knee replacement
    Chang, C. -W.
    Lai, K. -A.
    Yang, C. -Y.
    Lan, S. -M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (04): : 479 - 483
  • [8] Fixation of total knee arthroplasty improved by mobile-bearing design
    Russo, A
    Montagna, L
    Bragonzoni, L
    Zampagni, ML
    Marcacci, M
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (437) : 186 - 195
  • [9] The kinematics of fixed- and mobile-bearing total knee arthroplasty
    Most, E
    Li, G
    Schule, S
    Sultan, P
    Park, SE
    Zayontz, S
    Rubash, HE
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) : 197 - 207
  • [10] Alternate surgical approaches in mobile-bearing total knee arthroplasty
    Keblish, PA
    [J]. ORTHOPEDICS, 2002, 25 (02) : S257 - S264