In this paper, dynamic performance of wind farm comprising of three Squirrel Cage Induction Generators (SCIG) is analyzed for grid connected operation. Wind integration causes power imbalances and power system dynamics leading to system instability. The SCIG based wind turbine requires reactive power for magnetization which causes shortage of reactive power in distribution system and hence causes losses that lead to instability of power system. The behavior of the system is analyzed with variation in wind speed, unbalanced and nonlinear loads and three phase fault. The DSTATCOM is being used to improve the performance of wind farm as per the standard of grid code. The grid code demands that power plant of any kind should support electricity network throughout their operation. The performance enhancement mainly involves the power quality issues and grid stability and fault ride through (FRT) capability. A complete power balance analysis of the proposed system is presented under different operating conditions.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Static compensator for maintaining voltage stability of wind farm integration to a distribution network
    Lahacani, N. Aouzellag
    Aouzellag, D.
    Mendil, B.
    [J]. RENEWABLE ENERGY, 2010, 35 (11) : 2476 - 2482
  • [2] Control of static synchronous compensator with supplementary damping enhancement for wind farm voltage regulation
    Chen, W-L.
    Li, Z. -C.
    Xie, C. -Z.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (12) : 1211 - 1220
  • [3] Impact of static synchronous compensator on the stability of a wind farm: Case study of wind farm in Tunisia
    Karoui, Ridha
    Aouiti, Abdelkarim
    Zoghlami, Maha
    Bacha, Faouzi
    [J]. WIND ENGINEERING, 2016, 40 (06) : 555 - 568
  • [4] Impact of Wind Farm with Static Compensator under Grid Faults
    Mohamed, Shazly Abdo
    Shaaban, Salma AbdelAal
    [J]. 2018 TWENTIETH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2018, : 822 - 827
  • [5] LVRT Enhancement of a Grid-tied PMSG-based Wind Farm using Static VAR Compensator
    Dayo, Shoaib Ahmed
    Memon, Shafqat Hussain
    Uqaili, Mohammad Aslam
    Memon, Zubair Ahmed
    [J]. ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2021, 11 (03) : 7146 - 7151
  • [6] Reactive Optimization Control for the Wind Farm with Static Var Compensator (SVC)
    Zheng, Jian-Hong
    Li, Jie-Feng
    [J]. PROCEEDINGS OF THE 2012 24TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2012, : 2792 - 2795
  • [7] Mitigation of subsynchronous oscillations in a series compensated wind farm with static var compensator
    Varma, Rajiv K.
    Auddy, Soubhik
    [J]. 2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 3503 - +
  • [8] APPLICATION OF STATIC VAR COMPENSATOR (SVC) WITH FUZZY CONTROLLER FOR GRID INTEGRATION OF WIND FARM
    Narimani, Mehdi
    Varma, Rajiv K.
    [J]. 2010 23RD CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2010,
  • [9] Fuzzy Based Grid Voltage Stabilization in A Wind Farm Using Static VAR Compensator
    Vanitha, V.
    Shreyas, S.
    Vasanth, V.
    [J]. 2009 INTERNATIONAL CONFERENCE ON ADVANCES IN RECENT TECHNOLOGIES IN COMMUNICATION AND COMPUTING (ARTCOM 2009), 2009, : 14 - 18
  • [10] Comparative Study of the Performance of Static Synchronous Compensator, Series Compensator and Compensator /Battery Integrated to a Fixed Wind Turbine
    Jamila, E.
    Abdelmjid, S.
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING, 2016, 29 (04): : 581 - 589