Regional Changes in Cerebral Oxygenation Passive Movement Measured by Functional Near-infrared Spectroscopy

被引:1
|
作者
Sugawara, Kazuhiro [1 ]
Onishi, Hideaki [1 ]
Tsubaki, Atsuhiro [1 ]
Takai, Haruna [2 ]
Tokunaga, Yuta [3 ]
Tamaki, Hiroyuki [1 ]
机构
[1] Niigata Univ Hlth & Welf, Inst Human Movement & Med Sci, Niigata, Japan
[2] Marukawa Hosp, Dept Rehabil, Toyama, Japan
[3] Niigata Rehabil Hosp, Dept Rehabil, Niigata, Japan
来源
关键词
functional near-infrared spectroscopy; repetitive passive movement; movement frequency; time-dependent changes in cerebral oxygenation; systemic hemodynamic changes; FREQUENCY-DEPENDENT CHANGES; BLOOD-FLOW; MOTOR CORTEX; SOMATOSENSORY STIMULATION; CORTICAL ACTIVATION; HEMODYNAMIC-CHANGES; STIMULUS FREQUENCY; EVOKED-POTENTIALS; FINGER MOVEMENTS; RESPONSES;
D O I
10.3389/fnhum.2015.00641
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The aim of this study is to investigate the influence of passive movement repetition frequency at 1.5-Hz and 1-Hz on changes in cerebral oxygenation and assess the temporal properties of these changes using functional near-infrared spectroscopy (fNIRS). No significant differences in systemic hemodynamics were observed between resting and passive movement phases for either 1.5-Hz or 1-Hz trial. Changes in cortical oxygenation as measured by fNIRS in bilateral supplementary motor cortex (SMC), left primary motor cortex (M1), left primary somatosensory cortex (Si), and left posterior association area (PM) during passive movement of the right index finger revealed greater cortical activity at only 1.5-Hz movement frequency. However, there were no significant differences in the time for peak oxyhemoglobin (oxyHb) among regions (bilateral SMC, 206.4 +/- 14.4s; left M1, 199.1 +/- 14.8s; left S1, 207.3 +/- 9.4s; left PM, 219.1 +/- 10.2s). Therefore, our results that passive movement above a specific frequency may be required to elicit a changed in cerebral oxygenation, and the times of peak Delta oxyHb did not differ significantly among measured regions.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Cerebral oxygenation measured by near-infrared spectroscopy
    Wollert, HG
    Eckel, L
    [J]. ANNALS OF THORACIC SURGERY, 1997, 63 (01): : 292 - 292
  • [2] Sensitivity and reliability of cerebral oxygenation responses to postural changes measured with near-infrared spectroscopy
    Arjen Mol
    Jeffrey H. H. Woltering
    Willy N. J. M. Colier
    Andrea B. Maier
    Carel G. M. Meskers
    Richard J. A. van Wezel
    [J]. European Journal of Applied Physiology, 2019, 119 : 1117 - 1125
  • [3] Sensitivity and reliability of cerebral oxygenation responses to postural changes measured with near-infrared spectroscopy
    Mol, Arjen
    Woltering, Jeffrey H. H.
    Colier, Willy N. J. M.
    Maier, Andrea B.
    Meskers, Carel G. M.
    van Wezel, Richard J. A.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2019, 119 (05) : 1117 - 1125
  • [4] REGIONAL CHANGES IN CEREBRAL HEMODYNAMICS AS A RESULT OF A VISUAL STIMULUS MEASURED BY NEAR-INFRARED SPECTROSCOPY
    MEEK, JH
    ELWELL, CE
    KHAN, MJ
    ROMAYA, J
    WYATT, JS
    DELPY, DT
    ZEKI, S
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1995, 261 (1362) : 351 - 356
  • [5] Changes in tissue oxygenation of the porcine liver measured by near-infrared spectroscopy
    El-Desoky, AEH
    Seifalian, A
    Cope, M
    Delpy, D
    Davidson, B
    [J]. LIVER TRANSPLANTATION AND SURGERY, 1999, 5 (03): : 219 - 226
  • [6] Methylphenidate-induced changes in cerebral hemodynamics measured by functional near-infrared spectroscopy
    Weber, Peter
    Luetschg, Juerg
    Fahnenstich, Hubert
    [J]. JOURNAL OF CHILD NEUROLOGY, 2007, 22 (07) : 812 - 817
  • [7] Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry
    Daubeney, PEF
    Pilkington, SN
    Janke, E
    Charlton, GA
    Smith, DC
    Webber, SA
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (03): : 930 - 934
  • [8] Cerebral oxygenation monitoring: near-infrared spectroscopy
    Tobias, Joseph D.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (02) : 235 - 243
  • [9] Cerebral oxygenation changes during motor and somatosensory stimulation in humans, as measured bu near-infrared spectroscopy
    Obrig, H
    Wolf, T
    Doge, C
    Hulsing, JJ
    Dirnagl, U
    Villringer, A
    [J]. OXYGEN TRANSPORT TO TISSUE XVII, 1996, 388 : 219 - 224
  • [10] CHANGES IN HUMAN FETAL CEREBRAL HEMOGLOBIN CONCENTRATION AND OXYGENATION DURING LABOR MEASURED BY NEAR-INFRARED SPECTROSCOPY
    PEEBLES, DM
    EDWARDS, AD
    WYATT, JS
    BISHOP, AP
    COPE, M
    DELPY, DT
    REYNOLDS, EOR
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 166 (05) : 1369 - 1373