Linezolid extracorporeal removal during haemodialysis with high cut-off membrane in critically ill patients

被引:10
|
作者
Villa, Gianluca [1 ]
Cassetta, Maria Iris [2 ]
Tofani, Lorenzo [1 ]
Valente, Serafina [3 ]
Chelazzi, Cosimo [1 ]
Falsini, Silvia [1 ]
De Gaudio, Angelo Raffaele [1 ]
Novelli, Andrea [2 ]
Ronco, Claudio [4 ,5 ]
Adembri, Chiara [1 ]
机构
[1] Univ Florence, Sect Anesthesiol & Intens Care, Dept Hlth Sci, I-50134 Florence, Italy
[2] Univ Florence, Pharmacol Sect, Dept Hlth Sci, I-50134 Florence, Italy
[3] Univ Careggi, Azienda Osped, Dept Heart & Vessels, Florence, Italy
[4] San Bortolo Hosp, Dept Nephrol Dialysis & Transplantat, Vicenza, Italy
[5] IRRIV, Vicenza, Italy
关键词
Linezolid; Pharmacokinetics; Pharmacodynamics; High cut-off membrane; Sepsis; High-performance liquid chromatography; PROFILE;
D O I
10.1016/j.ijantimicag.2015.06.015
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Continuous venovenous haemodialysis with high cut-off membrane (HCO-CVVHD) is often used in critically ill septic patients with acute kidney injury (AKI) to sustain renal function and to remove circulating inflammatory mediators. The aim of this study was to analyse the extracorporeal removal of linezolid and related alterations in pharmacokinetic/pharmacodynamic (PK/PD) parameters during HCO-CVVHD. Three critically ill septic patients with AKI, treated with linezolid and HCO-CVVHD, were prospectively observed. To calculate the extracorporeal clearance of linezolid and the PK parameters, effluent, pre-filter and post-filter samples were contemporaneously collected before linezolid infusion, just after 1-h infusion (maximum serum concentration; C-max), at 3 h and 6 h after dosing, and before the next dose (trough serum concentration; Crnin). Linezolid C-max and C-min (pre-filter) ranged from 10.4-23.5 mg/L and from 2.9-10.3 mg/L. The dialysate saturation coefficient was 0.66-0.85 and the extracorporeal clearance with a diffusive dose of 35 mL/kg/h ranged from 2.1-2.5 L/h. Total linezolid clearance was between 1.7 L/h and 6.3 L/h. The total area under the plasma concentration-time curve (AUC(0-infinity)) ranged from 95.1 mg h/L to 352.9 mg h/L, in accordance with the different clinical conditions. AUCfree /MIC ratios were always <85 for an MIC of 4.0 mg/L, and two of three patients did not reach the optimal PK/PD target of >85 even when using an MIC of 2.0 mg/L. Although extracorporeal clearance may affect linezolid total clearance, the clinical features of critically ill septic patients appear to be mainly responsible for the high variability of linezolid serum concentrations. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:465 / 468
页数:4
相关论文
共 50 条
  • [1] HIGH CUT-OFF HAEMODIALYSIS INCREASES URAEMIC TOXIN REMOVAL
    Gondouin, B.
    Bevins, A.
    Cockwell, P.
    Vanholder, R.
    Hutchison, C. A.
    [J]. NEPHROLOGY, 2012, 17 : 47 - 47
  • [2] High cut-off dialysis in chronic haemodialysis patients
    Girndt, Matthias
    Fiedler, Roman
    Martus, Peter
    Pawlak, Michael
    Storr, Markus
    Bohler, Torsten
    Glomb, Marcus A.
    Liehr, Kristin
    Henning, Christian
    Templin, Markus
    Trojanowicz, Bogusz
    Ulrich, Christof
    Werner, Kristin
    Zickler, Daniel
    Schindler, Ralf
    [J]. EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2015, 45 (12) : 1333 - 1340
  • [3] DOES CONTINUOUS VENOVENOUS HAEMODIALYSIS PERFORMED WITH HIGH CUT-OFF MEMBRANE (CVVH-HCM) AFFECT INTRAVENOUS MICAFUNGIN THERAPY IN CRITICALLY ILL SEPTIC PATIENTS?
    Teresa, Tenorio
    Luque, Sara
    Pintado, Vicente
    Martinez Castro, Nilda
    Saez, Sergio
    Cobo, Javier
    Martin Davila, Pilar
    Fortun, Jesus
    Liano, Fernando
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 1414 - 1415
  • [4] Cytokine Removal with High Cut-Off Membrane: Review of Literature
    Villa, Gianluca
    Zaragoza, Jose J.
    Sharma, Aashish
    Neri, Mauro
    De Gaudio, A. Raffaele
    Ronco, Claudio
    [J]. BLOOD PURIFICATION, 2014, 38 (3-4) : 167 - 173
  • [5] Extracorporeal Removal of Myoglobin in Patients with Rhabdomyolysis and Acute Kidney Injury: Comparison of High and Medium Cut-Off Membrane and an Adsorber Cartridge
    Jerman, Alexander
    Andonova, Milena
    Persic, Vanja
    Gubensek, Jakob
    [J]. BLOOD PURIFICATION, 2022, 51 (11) : 907 - 911
  • [6] Removal of colistin during intermittent haemodialysis in two critically ill patients
    Marchand, Sandrine
    Frat, Jean-Pierre
    Petitpas, Franck
    Lemaitre, Florian
    Gobin, Patrice
    Robert, Rene
    Mimoz, Olivier
    Couet, William
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2010, 65 (08) : 1836 - 1837
  • [7] Solute Removal Capacity of High Cut-Off Membrane Plasma Separators
    Ohkubo, Atsushi
    Kurashima, Naoki
    Nakamura, Ayako
    Miyamoto, Satoko
    Iimori, Soichiro
    Rai, Tatemitsu
    [J]. THERAPEUTIC APHERESIS AND DIALYSIS, 2013, 17 (05) : 484 - 489
  • [8] HIGH CUT-OFF HAEMODIALYSIS LOWERS INFLAMMATORY STATUS IN CHRONIC DIALYSIS PATIENTS
    Hutchison, C. A.
    Meryon, I.
    Edwards, N.
    Hewins, P.
    Whitelegg, A.
    Drayson, M.
    Cockwell, P.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 592 - 593
  • [9] High cut-off dialysis in chronic haemodialysis patients reduces serum procalcific activity
    Zickler, Daniel
    Willy, Kevin
    Girndt, Matthias
    Fiedler, Roman
    Martus, Peter
    Storr, Markus
    Schindler, Ralf
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 (10) : 1706 - 1712
  • [10] Aggregated serum free light chains may prevent adequate removal by high cut-off haemodialysis
    Harding, Stephen
    Provot, Francois
    Beuscart, Jean-Baptise
    Cook, Mark
    Bradwell, Arthur R.
    Stringer, Stephanie
    White, Darren
    Cockwell, Paul
    Hutchison, Colin A.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2011, 26 (04) : 1438 - 1440