Detection of varicose vein recurrence by duplex ultrasound: intra- and interobserver reproducibility

被引:1
|
作者
Gauw, S. A. [1 ]
Pronk, P. [1 ]
Mooij, M. C. [1 ]
Gaastra, M. T. W. [1 ]
Lawson, J. A. [1 ]
van Vlijmen-van Keulen, C. J. [1 ]
机构
[1] Ctr Oosterwal, NL-1817 MS Alkmaar, Netherlands
关键词
varicose veins; duplex ultrasound; recurrence; intra- and inter-observer reproducibility; SURGERY;
D O I
10.1258/phleb.2011.011106
中图分类号
R61 [外科手术学];
学科分类号
摘要
In a long-term follow-up study comparing saphenofemoral ligation and stripping with endovenous laser ablation, the groin is examined yearly by duplex ultrasound (DUS) to detect postoperative varicose vein recurrence. Clear criteria are needed for the uniformity of DUS observations. Physicians taking care of the follow-up were evaluated by an intra- and interobserver analysis. DUS films of 22 patients with no recurrence and 22 patients with recurrence of varicose veins were twice interpreted in two sessions. Observations were analysed by a kappa test. Interpretations of DUS by experienced observers show a kappa >7. Improved kappa results were measured over time in our physician in training. In conclusion, the reproducibility of DUS studies performed by the experienced observers of the study is excellent.
引用
收藏
页码:109 / 111
页数:3
相关论文
共 50 条
  • [1] Intra- and interobserver reproducibility of pelvic ultrasound for the detection and measurement of endometriotic lesions
    Bean, E.
    Chaggar, P.
    Thanatsis, N.
    Dooley, W.
    Bottomley, C.
    Jurkovic, D.
    [J]. HUMAN REPRODUCTION OPEN, 2020, 2020 (02)
  • [2] The intra- and interobserver reproducibility of pelvic ultrasound for the detection and measurement of endometriotic lesions
    Bean, E.
    Chaggar, P.
    Thanatsis, N.
    Dooley, W.
    Bottomley, C.
    Jurkovic, D.
    [J]. HUMAN REPRODUCTION, 2020, 35 : I281 - I281
  • [3] Intra- and interobserver reproducibility of transvaginal ultrasound for the detection and measurement of endometriotic lesions of the bowel
    Chaggar, Prubpreet
    Tellum, Tina
    Cohen, Abigail
    Jurkovic, Davor
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2023, 102 (10) : 1306 - 1315
  • [4] Intra- and interobserver reproducibility of assessment of Doppler ultrasound findings in adnexal masses
    Zannoni, L.
    Savelli, L.
    Jokubkiene, L.
    Di Legge, A.
    Condous, G.
    Testa, A. C.
    Sladkevicius, P.
    Valentin, L.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 42 (01) : 93 - 101
  • [5] Intra- and interobserver reproducibility of the shoulder laxity examination
    Levy, AS
    Lintner, S
    Kenter, K
    Speer, KP
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (04): : 460 - 463
  • [6] Intra- and interobserver reproducibility of second trimester ultrasound cervical length measurement in a general population
    Banos, Nuria
    Burgos-Artizzu, Xavier P.
    Valenzuela-Alcaraz, Brenda
    Coronado-Gutierrez, David
    Perez-Moreno, Alvaro
    Ponce, Julia
    Gratacos, Eduard
    Palacio, Montse
    [J]. JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (05): : 999 - 1002
  • [7] Re: Intra- and interobserver reproducibility of assessment of Doppler ultrasound findings in adnexal masses.
    Alcazar, J. L.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 42 (01) : 5 - +
  • [8] Intra- and interobserver reproducibility of pancreatic perfusion by computed tomography
    Tiago S. Garcia
    Jean-Luc Engelholm
    Michaël Vouche
    Vânia N. Hirakata
    Cristiane B. Leitão
    [J]. Scientific Reports, 9
  • [9] Intra- and interobserver reproducibility of pancreatic perfusion by computed tomography
    Garcia, Tiago S.
    Engelholm, Jean-Luc
    Vouche, Michael
    Hirakata, Vania N.
    Leitao, Cristiane B.
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] Intra- and interobserver reproducibility in the evaluation of the optic disc by HRT
    Miglior, S
    Albe, E
    Guareschi, M
    Rossetti, L
    Orzalesi, N
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 : 45 - 45