Multidetector Computed Tomography Coronary Angiography: Sublingual Nitroglycerine Improves Image Quality Significantly Because of Peripheral Coronary Vasodilatation

被引:16
|
作者
Klass, Oliver [1 ]
Mutlu, Senguel [1 ]
Hohl, Kathrin [2 ]
Feuerlein, Sebastian [1 ]
Jeltsch, Martin [1 ]
Brambs, Hans-Juergen [1 ]
Hoffman, Martin H. K. [1 ]
机构
[1] Univ Hosp Ulm, Dept Diagnost & Intervent Radiol, D-89075 Ulm, Germany
[2] Univ Hosp Ulm, Inst Biometry, D-89075 Ulm, Germany
关键词
CT coronary angiography; nitrate; coronary artery disease (CAD); HEART-RATE; ROW CT; ARTERIES; PLAQUE; SPRAY;
D O I
10.1097/RCT.0b013e31817c6b33
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In this study, we investigated the influence of sublingual nitroglycerine (NTG) on the peripheral diameter, intraluminal contrast agent density, and image quality of coronary arteries during computed tomography coronary angiography (CTCA). Materials and Methods: Thirty patients with sublingual NTG application were matched to 30 patients without NTG. The diameters of the left anterior descending coronary artery (LAD), the left circumflex coronary artery and the right coronary artery were measured at 1-, 4-, and 8-cm length of each vessel as well as the intraluminal contrast agent density along the LAD. Vessel diameters and contrast attenuation at 4 and 8 cm were referenced against the values at 1 cm and processed as percentage reduction. Image quality of the posterior descending artery was assessed subjectively by 2 independent observers. Results: The percentage of peripheral vessel diameter reduction and the peripheral attenuation of contrast agent density for all measured coronary arteries was significantly smaller in the group with NTG administration. The image quality of the posterior descending artery was significantly higher in the group with NTG. Conclusions: Sublingual administration of NTG before CTCA results in improved diagnostic image quality because of a significant dilatation and improved intraluminal contrast agent density of the peripheral vessels.
引用
收藏
页码:199 / 203
页数:5
相关论文
共 50 条
  • [1] How image quality can be improved: our experience with multidetector computed tomography coronary angiography
    Ozturk, Ersin
    Kantarci, Mecit
    Durur-Subasi, Irmak
    Bayraktutan, Ummugulsum
    Karaman, Adem
    Bayram, Ednan
    Ogul, Hayri
    Ceviz, Naci
    [J]. CLINICAL IMAGING, 2007, 31 (01) : 11 - 17
  • [2] THE POTENTIAL OF 64-SLICE MULTIDETECTOR COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY TO REPLACE INVASIVE CORONARY ANGIOGRAPHY - THE ONTARIO MULTIDETECTOR COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY STUDY (OMCAS)
    Freeman, Michael Richard
    Chow, Ben
    Bowen, James
    Goeree, Ron
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [3] 64 multidetector CT coronary angiography: Effect of sublingual nitroglycerin on coronary luminal diameter and image quality
    Vanhoenacker, Piet K.
    Decramer, Isabel
    Samo, Giovanna
    Van Hoe, Lieven R.
    Wijns, William
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 179A - 179A
  • [4] Prognostic Value of Multidetector Coronary Computed Tomography Angiography
    Sharma, Abhishek
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (22) : 2313 - 2314
  • [5] Multidetector Computed Tomography Coronary Angiography for the Assessment of Coronary In-Stent Restenosis
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Pepi, Mauro
    Bartorelli, Antonio Luca
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (05): : 645 - 655
  • [6] Guidance of percutaneous coronary interventions by multidetector row computed tomography coronary angiography
    Rodriguez-Granillo, Gaston A.
    Rosales, Miguel A.
    Llaurado, Claudio
    Ivanc, Thomas B.
    Rodriguez, Alfredo E.
    [J]. EUROINTERVENTION, 2011, 6 (06) : 773 - 778
  • [7] Coronary artery aneurysms as seen on multidetector computed Tomography angiography
    Roy, Sion K.
    Kadakia, Jigar
    Shittu, Adekunle
    Budoff, Matthew J.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (07) : 1127 - 1132
  • [8] Role of Cardiac Multidetector Computed Tomography Beyond Coronary Angiography
    Sato, Akira
    Aonuma, Kazutaka
    [J]. CIRCULATION JOURNAL, 2015, 79 (04) : 712 - 720
  • [9] The effects of sublingual nitroglycerin administration in coronary computed tomography angiography
    Kutaiba, Numan
    Lukies, Matthew
    Galea, Michael
    Begbie, Mark
    Smith, Gerard
    Kearney, Leighton
    Spelman, Tim
    Lim, Ruth P.
    [J]. CLINICAL IMAGING, 2020, 60 (02) : 194 - 199
  • [10] Influence of cardiac function on image quality in coronary computed tomography angiography
    Nguyen, Tien C.
    Ohyama, Yoshiaki
    Taketomi-Takahashi, Ayako
    Nguyen, Huong T.
    Sugimoto, Akio
    Sato, Makito
    Sumiyoshi, Hisako
    Nakamura, Tetsuya
    Kurabayashi, Masahiko
    Tsushima, Yoshito
    [J]. CLINICAL IMAGING, 2019, 53 : 58 - 64