The run IIb trigger upgrade for the DO experiment

被引:7
|
作者
Abolins, M [1 ]
Ban, J
Bystricky, J
Calvet, D
Chapin, D
Edmunds, D
Evans, H
Han, L
Heintz, U
Hildreth, M
Hirosky, R
Johns, K
Johnson, M
Laurens, P
Le Dû, P
Mitrevski, J
Narain, M
Olsen, J
Padley, P
Parsons, J
Partridge, R
Perez, E
Sippach, W
Steinberg, J
Tarte, G
Wilson, G
Wood, D
Wu, S
机构
[1] Michigan State Univ, E Lansing, MI 48824 USA
[2] Columbia Univ, Nevis Labs, New York, NY 10027 USA
[3] CEA, CNRS, F-91191 Gif Sur Yvette, France
[4] Brown Univ, Providence, RI 02912 USA
[5] Univ Manchester, Manchester, Lancs, England
[6] Boston Univ, Boston, MA 02115 USA
[7] Univ Notre Dame, South Bend, IN 46556 USA
[8] Univ Virginia, Charlottesville, VA 22901 USA
[9] Univ Arizona, Tucson, AZ 85712 USA
[10] Fermilab Natl Accelerator Lab, Batavia, IL 60501 USA
[11] Rice Univ, Houston, TX 77005 USA
[12] Univ Kansas, Lawrence, KS 66045 USA
[13] Northeastern Univ, Boston, MA 02115 USA
关键词
clustering methods; digital filters; field programmable gate arrays; hadrons; particle collisions; tracking; triggering;
D O I
10.1109/TNS.2004.828811
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The increase in instantaneous luminosity anticipated in Run IIb of the Tevatron collider at Fermilab requires increased background rejection capabilities from the trigger system of the DO detector. A set of upgrades is under way to improve triggering at level 1 in the calorimeter and tracker, and at level 2 in the silicon track trigger and software triggers. Reductions of up to a factor of ten on the rates of high transverse momentum triggers are anticipated with the upgrades described.
引用
收藏
页码:340 / 344
页数:5
相关论文
共 50 条
  • [1] The CDF calorimeter upgrade for Run IIb
    Kuhlmann, S
    Frisch, H
    Cordelli, M
    Huston, J
    Miller, R
    Lami, S
    Paoletti, R
    Turini, N
    Iori, M
    Toback, D
    Ukegawa, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 39 - 41
  • [2] The Run IIb upgrade of the CDF silicon detectors
    Cabrera, S
    ADVANCED TECHNOLOGY AND PARTICLE PHYSICS, PROCEEDINGS, 2002, 1 : 171 - 177
  • [3] The CDF Run IIa silicon detector and its upgrade run IIb
    Issever, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 549 (1-3): : 7 - 10
  • [4] CDF run IIb silicon vertex detector DAQ upgrade
    Behari, S
    Bacchetta, N
    Bolla, G
    Cardoso, G
    Ciobanu, CI
    Flaugher, B
    Garcia-Sciveres, M
    Haber, C
    Hara, K
    Harr, R
    Hsiung, TH
    Junk, T
    Kim, S
    Lu, RS
    Lujan, P
    Maksimovic, P
    Merkel, P
    Nord, B
    Pavlicek, V
    Pellett, D
    Pursley, J
    Schuyler, B
    Shenai, A
    Treptow, K
    Weber, M
    Zimmermann, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3047 - 3054
  • [5] CDF run IIb silicon vertex detector DAQ upgrade
    Behari, S
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1143 - 1147
  • [6] Upgrade of the Global Muon Trigger for the CMS experiment
    Jeitler, M.
    Lingemann, J.
    Rabady, D.
    Rahbaran, B.
    Sakulin, H.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [7] The DO Run II trigger system
    Schwienhorst, R
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2005, 20 (16): : 3796 - 3798
  • [8] Upgrade of the ATLAS Central Trigger for LHC Run-2
    Artz, S.
    Bauss, B.
    Boterenbrood, H.
    Buescher, V.
    Degele, R.
    Dhaliwal, S.
    Ellis, N.
    Farthouat, P.
    Galster, G.
    Ghibaudi, M.
    Glatzer, J.
    Haas, S.
    Igonkina, O.
    Jakobi, K.
    Jansweijer, P.
    Kahra, C.
    Kaluza, A.
    Kaneda, M.
    Marzin, A.
    Ohm, C.
    Silva Oliveira, M. V.
    Pauly, T.
    Pottgen, R.
    Reiss, A.
    Schaefer, U.
    Schaeffer, J.
    Schipper, J. D.
    Schmieden, K.
    Schreuder, F.
    Simioni, E.
    Simon, M.
    Spiwoks, R.
    Stelzer, J.
    Tapprogge, S.
    Vermeulen, J.
    Vogel, A.
    Zinser, M.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [9] Performance and upgrade of the CMS electron and photon trigger for Run 2
    Sauvan, Jean-Baptiste
    16TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2014), 2015, 587
  • [10] Upgrade and operation of the DO central track trigger
    Buehler, Marc
    Anderson, John
    Angstadt, Robert
    Babukhadia, Levan
    Bhattacharjee, Mrinmoy
    Blazey, Gerald
    Boeriu, Oana
    Borcherding, Fred
    Connolly, Brian
    Cooke, Michael
    Corcoran, Marjorie
    Desai, Satish
    Evans, David
    Gershtein, Yuri
    Grannis, Paul
    Gruenendahl, Stefan
    Han, Liang
    Hazen, Eric
    Heintz, Ulrich
    Hensel, Carsten
    Hildreth, Mike
    Hoeth, Hendrik
    Hu, Yuan
    Jabeen, Shabnam
    Jain, Vivek
    Johnson, Marvin
    Khalatian, Samvel
    Khalatyan, Norik
    Lincoln, Don
    Linn, Stephan
    Liu, Yanwen
    Lizarazo, Juan
    Mackin, Dennis
    Maravin, Yurii
    Martin, Manuel
    Mommsen, Remigius K.
    Mutaf, Yildirim
    Narain, Meenakshi
    Noeding, Carsten
    Olsen, Jamieson
    Padley, Paul
    Pangilinan, Monica
    Partridge, Richard
    Ramirez-Gomez, Ricardo
    Rapisarda, Stefano
    Stevenson, Kyle
    Tomoto, Makoto
    Vachon, Brigitte
    Wijnen, Thei
    Wilcer, Neal
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 495 - 498