Microstream capnography technology: A new approach to an old problem

被引:60
|
作者
Colman, Y
Krauss, B
机构
[1] Harvard Univ, Childrens Hosp, Sch Med, Dept Pediat,Div Emergency Med, Boston, MA 02115 USA
[2] Oridion Med Inc, Res & Dev Unit, Jerusalem, Israel
关键词
monitoring; carbon dioxide; molecular correlation spectroscopy; capnography; capnometry; sampling; neonates; infants; human; microstream; filterline;
D O I
10.1023/A:1009981115299
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Significant technical limitations inherent in blackbody infrared technology used in conventional sidestream and mainstream capnography have hindered the acceptance and growth of capnography as a monitoring tool outside the operating room environment. We describe a new technology (Microstream(TM)) for CO2 monitoring, based on molecular correlation spectroscopy, which results in a highly efficient and selective emission of a spectrum of discrete wavelengths exactly matching those for CO2 absorption. The CO2 specific emissions allow for an extremely small sample cell (15 mu l), which in turn, permits the use of a very low sample flow rate (50 ml/min) without compromising waveform integrity or end-tidal CO2 accuracy. Design and technology features of the CO2 emission source, sample cell, and breath sampling circuits are described.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 50 条
  • [1] Microstream capnography technology: A new approach to an old problem
    Research and Development Unit, Oridion Medical Inc., Jerusalem, Israel
    不详
    不详
    J. Clin. Monit. Comput., 6 (403-409):
  • [2] Microstream Capnography Technology: A New Approach to an Old Problem
    Yehoshua Colman
    Baruch Krauss
    Journal of Clinical Monitoring and Computing, 1999, 15 : 403 - 409
  • [3] Safety of Microstream Capnography Monitoring in Patients Under Sedation for Colonoscopy
    Oba, Sibel
    Turk, Hacer Sebnem
    Isil, Canan Tulay
    Sayin, Pinar
    Kilinc, Leyla
    HASEKI TIP BULTENI-MEDICAL BULLETIN OF HASEKI, 2019, 57 (03): : 232 - 239
  • [4] New technology, old problem
    不详
    COMPUTERS & SECURITY, 2001, 20 (05) : 353 - 354
  • [5] MICROSTREAM CAPNOGRAPHY IMPROVES PATIENT MONITORING DURING DEEP SEDATION
    Frattari, A.
    Cacciafiori, G.
    Isacco, V.
    Baldassarre, N.
    Spina, T.
    DIGESTIVE AND LIVER DISEASE, 2010, 42 : S330 - S330
  • [6] A New Approach to an Old Problem
    不详
    AMERICAN JOURNAL OF NURSING, 1953, 53 (01) : 78 - 80
  • [7] A NEW APPROACH TO AN OLD PROBLEM
    MASON, TM
    TRANSMISSION & DISTRIBUTION, 1994, 46 (11): : 66 - &
  • [8] A new approach to an old problem
    Lee, AG
    Andrews, DW
    SURVEY OF OPHTHALMOLOGY, 1999, 43 (06) : 519 - 524
  • [9] NEW APPROACH TO AN OLD PROBLEM
    MOYLAN, DW
    AMERICAN BAR ASSOCIATION JOURNAL, 1983, 69 (JAN): : 46 - 49
  • [10] A NEW APPROACH TO AN OLD PROBLEM
    GREEN, BN
    WATER SERVICES, 1985, 89 (1069): : 107 - 107