ACL reconstruction using bone-patella tendon-bone autograft: press-fit technique vs. interference screw fixation

被引:19
|
作者
Sarzaeem, M. M. [1 ]
Najafi, F. [1 ]
Razi, M. [2 ]
Najafi, M. A. [3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Dept Orthoped Surg, Imam Hossein Hosp, Tehran, Iran
[2] Iran Univ Med Sci, Rassole Akram Hosp, Dept Orthopaed & Sport Med, Tehran, Iran
[3] Isfahan Univ Med Sci, Fac Med, Esfahan, Iran
关键词
Anterior cruciate ligament reconstruction; Bone-patellar tendon-bone graft; Press fit fixation; Interference screw; Outcome; ANTERIOR CRUCIATE LIGAMENT; FOLLOW-UP; ARTHROSCOPIC RECONSTRUCTION; GRAFT FIXATION; KNEE; OSTEOARTHRITIS; STRENGTH;
D O I
10.1007/s00402-014-1999-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The gold standard in ACL reconstructions has been the bone-patellar tendon-bone autograft fixed with interference screws. This prospective, randomized clinical trial aimed to compare two methods of fixation for BPTB grafts: press-fit fixation vs. interference screw, over a 12-month follow-up interval. 158 patients with an average age of 29.8 years, between 2011 and 2012, were treated for torn ACL. 82 patients underwent reconstruction with BPTB autograft with a press fit fixation technique, and in 76 cases an interference screw was used. At the time of final follow-up, 71 patients in press-fit group and 65 patients in interference screw group were evaluated in terms of return to pre-injury activity level, pain, knee stability, range of motion, IKDC score and complications. At 12-month follow-up, 59 (83 %) and 55 (85 %) in press-fit and screw group, respectively had good-to-excellent IKDC score (p > 0.05). The mean laxity assessed using a KT-1000 arthrometer improved to 2.7 and 2.5 mm in press-fit and screw group, respectively. Regarding Lachman and pivot shift test, there was a statistically significant improvement in the integrity of the ACL in both the groups, but no significant differences was noted between groups. There were no significant differences in terms of femur circumference difference, effusion, knee range of motion, pain and complications. The press-fit technique is an efficient procedure. Its outcome was comparable with the interference screw group. Furthermore it has unlimited bone-to-bone healing, no need for removal of hardware, ease for revision and cost effectiveness.
引用
收藏
页码:955 / 962
页数:8
相关论文
共 50 条
  • [1] ACL reconstruction using bone–patella tendon–bone autograft: press-fit technique vs. interference screw fixation
    M. M. Sarzaeem
    F. Najafi
    M. Razi
    M. A. Najafi
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 955 - 962
  • [2] Anterior Cruciate Ligament Reconstruction Using Bone-Patella Tendon-Bone Autograft With Press-Fit Femoral Fixation: The Original Chambat Technique
    Levy, Yoann
    Gousopoulos, Lampros
    Hopper, Graeme P.
    Grob, Charles
    Vieira, Thais Dutra
    Fayard, Jean-Marie
    Thaunat, Mathieu
    Chambat, Pierre
    Sonnery-Cottet, Bertrand
    ARTHROSCOPY TECHNIQUES, 2022, 11 (11): : E1889 - E1895
  • [3] Bone-patella tendon-bone autograft anterior cruciate ligament reconstruction
    Schoderbek, Robert J., Jr.
    Treme, Gehron P.
    Miller, Mark D.
    CLINICS IN SPORTS MEDICINE, 2007, 26 (04) : 525 - +
  • [4] Femoral press-fit fixation in ACL reconstruction using bone-patellar tendon-bone autograft: results at 15 years follow-up
    Widuchowski, Wojciech
    Widuchowska, Malgorzata
    Koczy, Bogdan
    Dragan, Szymon
    Czamara, Andrzej
    Tomaszewski, Wieslaw
    Widuchowski, Jerzy
    BMC MUSCULOSKELETAL DISORDERS, 2012, 13
  • [5] Femoral press-fit fixation in ACL reconstruction using bone-patellar tendon-bone autograft: results at 15 years follow-up
    Wojciech Widuchowski
    Malgorzata Widuchowska
    Bogdan Ko czy
    Szymon Dragan
    Andrzej Czamara
    Wieslaw Tomaszewski
    Jerzy Widuchowski
    BMC Musculoskeletal Disorders, 13
  • [6] Management of patella fractures associated with central third bone-patella tendon-bone autograft ACL reconstructions
    Berg, EE
    ARTHROSCOPY, 1996, 12 (06): : 756 - 759
  • [7] ACL reconstruction using bone-patellar tendon-bone press-fit fixation: 10-year clinical results
    Hertel, P
    Behrend, H
    Cierpinski, T
    Musahl, V
    Widjaja, G
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (04) : 248 - 255
  • [8] ACL reconstruction using bone-patellar tendon-bone press-fit fixation: 10-year clinical results
    P. Hertel
    H. Behrend
    T. Cierpinski
    V. Musahl
    G. Widjaja
    Knee Surgery, Sports Traumatology, Arthroscopy, 2005, 13 : 248 - 255
  • [9] Arthrascopic anterior cruciate ligament reconstruction with a bone-patellar tendon-bone autograft in press-fit technique
    Boszotta, H.
    ARTHROSKOPIE, 2013, 26 (01) : 42 - 46
  • [10] One-stage revision ACL reconstruction after primary ACL double bundle reconstruction: is bone-patella tendon-bone autograft reliable?
    Tomihara, Tomohiro
    Hashimoto, Yusuke
    Taniuchi, Masatoshi
    Takigami, Junsei
    Han, Changhun
    Shimada, Nagakazu
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (05) : 1653 - 1661