Inverse size-exclusion chromatography for distributed pore and solute sizes

被引:19
|
作者
Goto, M
McCoy, BJ
机构
[1] Kumamoto Univ, Dept Appl Chem & Biochem, Kumamoto 8608555, Japan
[2] Univ Calif Davis, Dept Chem Engn & Mat Sci, Davis, CA 95616 USA
关键词
inverse size-exclusion chromatography; pore-size distribution; polydisperse solute; continuous mixture; mass transfer;
D O I
10.1016/S0009-2509(99)00352-8
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The pore-size distribution (PSD) of a liquid-saturated porous medium can be determined by inverse size-exclusion chromatography (ISEC) under suitable conditions. To quantify the limitations of longitudinal dispersion, intraparticle diffusion, and adsorption, we present a mathematical model for chromatographic procedures with polydisperse solutes. Results are applicable to either inverse or ordinary SEC. The conventional ISEC procedure with monodisperse polymer standards is a special case of the general development. Chromatographic responses for polydisperse solutes permit determination of the pore-size distribution by a deconvolution procedure if adsorption is negligible. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:723 / 732
页数:10
相关论文
共 50 条
  • [1] Inverse Size-Exclusion Chromatography
    Sepsey, Annamaria
    Bacskay, Ivett
    Felinger, Attila
    [J]. ADVANCES IN CHROMATOGRAPHY, VOL 55, 2018, 55 : 205 - 227
  • [2] Packings of an unidimensional regular pore structure as model packings in size-exclusion and inverse size-exclusion chromatography
    Kurganov, A
    Unger, K
    Issaeva, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 753 (02) : 177 - 190
  • [3] Application of inverse size-exclusion chromatography in evaluating pore size structure of chromatographic media
    Chi, Weiya
    Hou, Henglei
    Kang, Hongyan
    Qi, Li
    Jin, Haibo
    Zhang, Rongyue
    [J]. Jingxi Huagong/Fine Chemicals, 2020, 37 (07): : 1320 - 1326
  • [4] Determination of pore size distributions of porous chromatographic adsorbents by inverse size-exclusion chromatography
    Yao, Y
    Lenhoff, AM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1037 (1-2) : 273 - 282
  • [5] Pore structural characterization of monolithic silica columns by inverse size-exclusion chromatography
    Grimes, Brian A.
    Skudas, Romas
    Unger, Klaus K.
    Lubda, Dieter
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1144 (01) : 14 - 29
  • [6] Thermodynamic equilibrium of the solute distribution in size-exclusion chromatography
    Striegel, AM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) : 241 - 245
  • [7] Pore size distributions of cation-exchange adsorbents determined by inverse size-exclusion chromatography
    DePhillips, P
    Lenhoff, AM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 883 (1-2) : 39 - 54
  • [8] CALIBRATION OF SIZE-EXCLUSION CHROMATOGRAPHY - USE OF A DOUBLE GAUSSIAN DISTRIBUTION FUNCTION TO DESCRIBE PORE SIZES
    HARLAN, JE
    PICOT, D
    LOLL, PJ
    GARAVITO, RM
    [J]. ANALYTICAL BIOCHEMISTRY, 1995, 224 (02) : 557 - 563
  • [9] THE EFFECT OF SOLUTE SIZE AND SHAPE ON THE ELUTION VOLUME IN SIZE-EXCLUSION CHROMATOGRAPHY
    STYRING, MG
    PRICE, C
    BOOTH, C
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 319 (02): : 115 - 120
  • [10] CHARACTERIZATION OF HEMODIALYSIS MEMBRANES BY INVERSE SIZE-EXCLUSION CHROMATOGRAPHY
    BROEK, AP
    TEUNIS, HA
    BARGEMAN, D
    SPRENGERS, ED
    STRATHMANN, H
    SMOLDERS, CA
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1995, 99 (03) : 217 - 228