Beating heart catheter-based edge-to-edge mitral valve procedure in a porcine model - Efficacy and healing response

被引:80
|
作者
Fann, JI
St Goar, FG
Komtebedde, J
Oz, MC
Block, PC
Foster, E
Butany, J
Feldman, T
Burdon, TA
机构
[1] Stanford Univ, Med Ctr, Dept Cardiothorac Surg, Stanford, CA 94305 USA
[2] Cardiovasc Inst, Mountain View, CA USA
[3] Evalve Inc, Redwood City, CA USA
[4] Columbia Univ, New York, NY USA
[5] Emory Univ, Atlanta, GA 30322 USA
[6] Univ Calif San Francisco, San Francisco, CA 94143 USA
[7] Univ Toronto, Toronto, ON, Canada
[8] Evanston NW Healthcare, Evanston, IL USA
关键词
mitral valve; catheters; surgery; echocardiography;
D O I
10.1161/01.CIR.0000139855.12616.15
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Surgical edge-to-edge repair has been used in the treatment of mitral regurgitation. We evaluated the ability of a catheter-delivered clip (Evalve, Inc) to achieve edge-to-edge mitral valve approximation without cardiopulmonary bypass and the healing response of this technique. Methods and Results - Twenty-one pigs underwent general anesthesia and left thoracotomy. A 10F flexible delivery catheter with a clip was placed into the left atrium. With echocardiographic and fluoroscopic guidance, the clip grasped and approximated the mid portion of the anterior and posterior leaflets. After a double orifice had been confirmed, the clip was detached and the catheter withdrawn. All animals survived and had successful clip placement. Three animals were euthanized at 4 weeks, 9 at 12 weeks, 1 at 17 weeks, 7 at 24 weeks, and 1 at 52 weeks. The clip was well positioned, with leaflet approximation in all animals except 1, in which the clip separated from the posterior leaflet at 4 weeks without affecting valve function. The clip was modified and implanted in 4 pigs; all were intact at 12 to 24 weeks. Scanning electron microscopy showed clip encapsulation with complete endothelialization. Mitral stenosis and thromboembolism did not develop. Two animals developed endocarditis ( 1 at 12 weeks and 1 at 17 weeks). Progressive healing occurred in all other animals. Conclusions - Edge-to-edge mitral valve approximation can be successfully and reliably achieved with a catheter-delivered clip without cardiopulmonary bypass, resulting in durable healing. The success of this device supports the development of a percutaneous catheter- based system for mitral valve repair.
引用
收藏
页码:988 / 993
页数:6
相关论文
共 50 条
  • [1] Catheter-Based Edge-to-Edge Mitral Valve Repair After Percutaneous Mitral Valve Annuloplasty Failure
    Grasso, Carmelo
    Attizzani, Guilherme F.
    Ohno, Yohei
    Dipasqua, Fabio
    Mangiafico, Sarah
    Ministeri, Margherita
    Caggegi, Anna
    Cannata, Stefano
    Scandura, Salvatore
    Tamburino, Corrado
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (07) : E85 - E86
  • [2] Beating heart porcine high-fidelity simulator for the training of edge-to-edge mitral valve repair
    Naegele, Felix
    Gollmann-Tepekoeylue, Can
    Holfeld, Johannes
    Poelzl, Gerhard
    Metzler, Bernhard
    Hintringer, Florian
    Adukauskaite, Agne
    Mueller, Ludwig
    Grimm, Michael
    Bonaros, Nikolaos
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2019, 131 : 379 - 379
  • [3] Catheter-based edge-to-edge mitral valve repair for pulmonary pressure reduction and to postpone heart transplantation in a teenaged patient
    Messner, Moritz
    Hintringer, Florian
    Mueller, Silvana
    Zaruba, Marc Michael
    Bonaros, Nikolaos
    Antretter, Herwig
    Basic, Daniel
    Poelzl, Gerhard
    [J]. ESC HEART FAILURE, 2018, 5 (01): : 201 - 203
  • [4] Catheter-Based Edge-to-Edge Mitral Valve Repair After Partial Rupture of Surgical Annuloplasty Ring
    Fuchs, Felipe C.
    Hammerstingl, Christoph
    Werner, Nikos
    Grube, Eberhard
    Nickenig, Georg
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (15) : E263 - E264
  • [5] The Effect of a Novel Transcatheter Edge-to-Edge Mitral Valve Repair Device in a Porcine Model of Mitral Regurgitation
    Ge, Zhenyi
    Pan, Wenzhi
    Pan, Cuizhen
    Zhou, Daxin
    Li, Wei
    Wei, Lai
    Shu, Xianhong
    Ge, Junbo
    [J]. ACTA CARDIOLOGICA SINICA, 2020, 36 (06) : 620 - 625
  • [6] Transcatheter edge-to-edge mitral valve repair in heart failure
    Orban, Mathias
    Orban, Martin
    Braun, Daniel
    Nabauer, Michael
    Massberg, Steffen
    Hausleiter, Joerg
    [J]. MINERVA CARDIOANGIOLOGICA, 2017, 65 (03): : 314 - 320
  • [7] Edge-to-edge mitral valve repair as a bridge to heart transplantation
    Messner, M.
    Hirsch, J.
    Mueller, S.
    Adukauskaite, A.
    Hintringer, F.
    Bonaros, N.
    Dumfahrt, J.
    Antretter, H.
    Poelzl, G.
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 93 - 93
  • [8] Endovascular edge-to-edge mitral valve repair - Short-term results in a porcine model
    St Goar, FG
    Fann, JI
    Komtebedde, J
    Foster, E
    Oz, MC
    Fogarty, TJ
    Feldman, T
    Block, PC
    [J]. CIRCULATION, 2003, 108 (16) : 1990 - 1993
  • [9] Percutaneous Edge-to-Edge Mitral Valve Repair: Beyond the Left Heart
    Italia, Leonardo
    Adamo, Marianna
    Lupi, Laura
    Scodro, Marta
    Curello, Salvatore
    Metra, Marco
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2021, 34 (10) : 1038 - 1045
  • [10] Edge-to-Edge mitral valve repair for preoperative bridging to heart transplantation
    Moritz, Messner
    Staggl, Simon
    Maria, Ungericht
    Marc-Michael, Zaruba
    Christian, Puelacher
    Lukas, Stastny
    Jakob, Hirsch
    Herwig, Antretter
    Thomas, Schuetz
    Nikolaos, Bonaros
    Julia, Dumfarth
    Christoph, Brenner
    Axel, Bauer
    Gerhard, Poelzl
    [J]. IJC HEART & VASCULATURE, 2024, 55