Parameter identification and sedative sensitivity analysis of an agitation-sedation model

被引:2
|
作者
Rudge, Andrew D.
Chase, J. Geoffrey
Shaw, Geoffrey M.
Lee, Dominic
Hann, Christopher E.
机构
[1] Univ Canterbury, Dept Mech Engn, Ctr Bioengn, Christchurch 1, New Zealand
[2] Univ Otago, Sch Med & Hlth Sci, Dept Intens Care Med, Christchurch Hosp, Christchurch, New Zealand
[3] Univ Canterbury, Ctr Bioengn, Dept Math & Stat, Christchurch 1, New Zealand
关键词
parameter fitting; system identification; integral-based; physiological models; dynamic modelling; agitation; sedation;
D O I
10.1016/j.cmpb.2006.06.011
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Sedation administration and agitation management are fundamental activities in any intensive care unit. A lack of objective measures of agitation and sedation, as well as poor understanding of the underlying dynamics, contribute to inefficient outcomes and expensive healthcare. Recent models of agitation-sedation dynamics have enhanced understanding of the underlying dynamics and enable development of advanced protocols for semi-automated sedation administration. In this research, the agitation-sedation model parameters are identified using an integral-based fitting method developed in this work. Parameter variance is then analysed over 37 intensive care unit patients. The parameter identification method is shown to be effective and computationally inexpensive, making it suited to real-time clinical control applications. Sedative sensitivity, an important model parameter, is found to be both patient-specific and time-varying. However, while the variation between patients is observed to be as large as a factor 10, the observed variation in time is smaller, and varies slowly over a period of days rather than hours. The high fitted model performance across all patients show that the agitation-sedation model presented captures the fundamental dynamics of the agitation-sedation system. Overall, these results provide additional insight into the system and clinical dynamics of sedation management. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:211 / 221
页数:11
相关论文
共 50 条
  • [1] Modelling and control of the agitation-sedation cycle
    Rudge, AD
    Chase, JG
    Shaw, GM
    Johnston, L
    Wake, GC
    MODELLING AND CONTROL IN BIOMEDICAL SYSTEMS 2003 (INCLUDING BIOLOGICAL SYSTEMS), 2003, : 89 - 94
  • [2] Physiological modelling of agitation-sedation dynamics
    Rudge, AD
    Chase, JG
    Shaw, GM
    Lee, D
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (01) : 49 - 59
  • [3] Impact of control on agitation-sedation dynamics
    Rudge, AD
    Chase, JG
    Shaw, GM
    Lee, D
    Wake, GC
    Hudson, IL
    Johnston, L
    CONTROL ENGINEERING PRACTICE, 2005, 13 (09) : 1139 - 1149
  • [4] Physiologically-based minimal model of agitation-sedation dynamics
    Rudge, AD
    Chase, JG
    Shaw, GA
    Lee, D
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 774 - 777
  • [5] Physiological modelling of agitation-sedation dynamics including endogenous agitation reduction
    Rudge, A. D.
    Chase, J. G.
    Shaw, G. M.
    Lee, D.
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (07) : 629 - 638
  • [6] Predicting Agitation-Sedation Levels in Intensive Care Unit Patients: Development of an Ensemble Model
    Dai, Pei-Yu
    Lin, Pei-Yi
    Sheu, Ruey-Kai
    Liu, Shu-Fang
    Wu, Yu-Cheng
    Wu, Chieh-Liang
    Chen, Wei-Lin
    Huang, Chien-Chung
    Lin, Guan-Yin
    Chen, Lun-Chi
    JMIR MEDICAL INFORMATICS, 2025, 13
  • [7] Copula Modelling of Nurses' Agitation-Sedation Rating of ICU Patients
    Tursunalieva, Ainura
    Hudson, Irene
    Chase, Geoff
    STATISTICS AND DATA SCIENCE, RSSDS 2019, 2019, 1150 : 148 - 161
  • [8] Modeling and control of the agitation-sedation cycle for critical care patients
    Chase, JG
    Rudge, AD
    Shaw, GM
    Wake, GC
    Lee, D
    Hudson, IL
    Johnston, L
    MEDICAL ENGINEERING & PHYSICS, 2004, 26 (06) : 459 - 471
  • [9] An insight into the use of sedative medications and Richmond Agitation-Sedation Scale scores in the intensive care units at Calderdale and Huddersfield Foundation Trust
    Morris, E.
    Goellner, S.
    ANAESTHESIA, 2019, 74 : 42 - 42
  • [10] Comparison of depth of sedation measured by PSA 4000 and Richmond Agitation-Sedation scale (RASS)
    Sessler, CN
    Kollef, M
    Hamilton, A
    Grap, NJ
    Jefferson, D
    CHEST, 2005, 128 (04) : 151S - 152S