Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysis

被引:19
|
作者
Islam, Sheikh Mohammed Shariful [1 ,2 ,3 ]
Chow, Clara K. [2 ,3 ,4 ]
Daryabeygikhotbehsara, Reza [1 ]
Subedi, Narayan [1 ]
Rawstorn, Jonathan [1 ]
Tegegne, Teketo [1 ]
Karmakar, Chandan [5 ]
Siddiqui, Muhammad U. [6 ,7 ]
Lambert, Gavin [8 ]
Maddison, Ralph [1 ]
机构
[1] Deakin Univ, Inst Phys Act & Nutr, Melbourne, Vic, Australia
[2] Univ Sydney, Westmead Appl Res Ctr, Sydney, NSW, Australia
[3] UNSW, George Inst Global Hlth, Sydney, NSW, Australia
[4] Westmead Hosp, Dept Cardiol, Sydney, NSW, Australia
[5] Deakin Univ, Sch IT, Geelong, Vic, Australia
[6] Marshfield Clin Hlth Syst, Rice Lake, WI USA
[7] George Washington Univ, Washington, DC USA
[8] Swinburne Univ Technol, Iverson Hlth Innovat Res Inst, Melbourne, Vic, Australia
来源
关键词
Hypertension; Cardiovascular disease; Blood pressure (BP); Validation; Digital health; Non-invasive; PULSE TRANSIT-TIME; HYPERTENSION; SENSOR;
D O I
10.1093/ehjdh/ztac021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims High blood pressure (BP) is the commonest modifiable cardiovascular risk factor, yet its monitoring remains problematic. Wearable cuffless BP devices offer potential solutions; however, little is known about their validity and utility. We aimed to systematically review the validity, features and clinical use of wearable cuffless BP devices. Methods and results We searched MEDLINE, Embase, IEEE Xplore and the Cochrane Database till December 2019 for studies that reported validating cuffless BP devices. We extracted information about study characteristics, device features, validation processes, and clinical applications. Devices were classified according to their functions and features. We defined devices with a mean systolic BP (SBP) and diastolic BP (DBP) biases of <5mmHg as valid as a consensus. Our definition of validity did not include assessment of device measurement precision, which is assessed by standard deviation of the mean difference-a critical component of ISO protocol validation criteria. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies version 2 tool. A random-effects model meta-analysis was performed to summarise the mean biases for SBP and DBP across studies. Of the 430 studies identified, 16 studies (15 devices, 974 participants) were selected. The majority of devices (81.3%) used photoplethysmography to estimate BP against a reference device; other technologies included tonometry, auscultation and electrocardiogram. In addition to BP and heart rate, some devices also measured night-time BP (n=5), sleep monitoring (n=3), oxygen saturation (n=3), temperature (n=2) and electrocardiogram (n=3). Eight devices showed mean biases of <5 mmHg for SBP and DBP compared with a reference device and three devices were commercially available. The meta-analysis showed no statistically significant differences between the wearable and reference devices for SBP (pooled mean difference=3.42mmHg, 95% CI: -2.17, 9.01, I-2 95.4%) and DBP (pooled mean=1.16mmHg, 95% CI: -1.26, 3.58, I-2 87.1%). Conclusion Several cuffless BP devices are currently available using different technologies, offering the potential for continuous BP monitoring. The variation in standards and validation protocols limited the comparability of findings across studies and the identification of the most accurate device. Challenges such as validation using standard protocols and in real-life settings must be overcome before they can be recommended for uptake into clinical practice.
引用
收藏
页码:323 / 337
页数:15
相关论文
共 50 条
  • [1] WEARABLE CUFFLESS BLOOD PRESSURE MONITORING DEVICES: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Islam, Sheikh Mohammed Shariful
    Maddison, Ralph
    [J]. JOURNAL OF HYPERTENSION, 2023, 41 : E203 - E203
  • [2] Relatability of Blood Pressure Monitoring With Wearable Cuffless Devices
    Chrysant, Steven G.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2022, 169 : 145 - 147
  • [3] Clinical Uses of Cuffless Blood Pressure Monitoring Devices Using Photoplethysmography as A Promising Ambulatory Telemonitoring Tool: A Systematic Review and Meta-Analysis
    Florencia, Audrey
    Milla, Clonia
    Julian, Timothy
    [J]. JOURNAL OF HYPERTENSION, 2023, 41 (SUPPL 2)
  • [4] NONINVASIVE CONTINUOUS BLOOD PRESSURE MONITORING COMPARED TO INVASIVE BLOOD PRESSURE MONITORING: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Kim, Sang-Hyun
    Lilot, Marc
    Sidhu, Kulraj
    Cannesson, Maxime
    [J]. ANESTHESIA AND ANALGESIA, 2013, 117 : 32 - 33
  • [5] Ambulatory Blood Pressure Monitoring in Individuals with HIV: A Systematic Review and Meta-Analysis
    Kent, Shia T.
    Bromfield, Samantha G.
    Burkholder, Greer A.
    Falzon, Louise
    Oparil, Suzanne
    Overton, Edgar T.
    Mugavero, Michael J.
    Schwartz, Joseph E.
    Shimbo, Daichi
    Muntner, Paul
    [J]. PLOS ONE, 2016, 11 (02):
  • [6] Efficacy of Monitoring Devices in Support of Prevention of Pressure Injuries: Systematic Review and Meta-analysis
    Walia, Gurjot S.
    Wong, Alison L.
    Lo, Andrea Y.
    Mackert, Gina A.
    Carl, Hannah M.
    Pedreira, Rachel A.
    Bello, Ricardo
    Aquino, Carla S.
    Padula, William V.
    Sacks, Justin M.
    [J]. ADVANCES IN SKIN & WOUND CARE, 2016, 29 (12) : 566 - 573
  • [7] Validation of Cuffless Blood Pressure Monitoring Using Wearable Device
    Baek, JinHyeok
    Kim, Junho
    Kim, Namho
    Lee, Daeho
    Park, Sung-Min
    [J]. PROCEEDINGS OF TENCON 2018 - 2018 IEEE REGION 10 CONFERENCE, 2018, : 0416 - 0419
  • [8] Validating cuffless continuous blood pressure monitoring devices
    Hu, Jiun-Ruey
    Martin, Gabrielle
    Iyengar, Sanjna
    Kovell, Lara C.
    Plante, Timothy B.
    van Helmond, Noud
    Dart, Richard A.
    Brady, Tammy M.
    Turkson-Ocran, Ruth-Alma N.
    Juraschek, Stephen P.
    [J]. CARDIOVASCULAR DIGITAL HEALTH JOURNAL, 2023, 4 (01): : 9 - 20
  • [9] Home blood pressure monitoring in the antenatal and postpartum period: A systematic review meta-analysis
    Kalafat, Erkan
    Benlioglu, Can
    Thilaganathan, Basky
    Khalil, Asma
    [J]. PREGNANCY HYPERTENSION-AN INTERNATIONAL JOURNAL OF WOMENS CARDIOVASCULAR HEALTH, 2020, 19 : 44 - 51
  • [10] Automated seizure detection with noninvasive wearable devices: A systematic review and meta-analysis
    Naganur, Vaidehi
    Sivathamboo, Shobi
    Chen, Zhibin
    Kusmakar, Shitanshu
    Antonic-Baker, Ana
    O'Brien, Terence J.
    Kwan, Patrick