CaSO4:Dy microphosphor for thermal neutron dosimetry

被引:19
|
作者
Bhadane, Mahesh S. [1 ]
Mandlik, Nandkumar [2 ]
Patil, B. J. [3 ]
Dahiwale, S. S. [1 ]
Sature, K. R. [1 ]
Bhoraskar, V. N. [1 ]
Dhole, S. D. [1 ]
机构
[1] Savitribai Phule Pune Univ, Dept Phys, Microtron Accelerator Lab, Pune 411007, Maharashtra, India
[2] Savitribai Phule Pune Univ, Dept Phys, Fergusson Coll, Pune 411007, Maharashtra, India
[3] Abasaheb Garware Coll, Dept Phys, Pune 411004, Maharashtra, India
关键词
Cf-252; FLUKA code; Microphosphor; Thermoluminescence; CGCD; THERMOLUMINESCENCE; PHOSPHOR; KINETICS; OSL;
D O I
10.1016/j.jlumin.2015.10.025
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dysprosium-doped calcium sulphate (CaSO4:Dy) microphosphor was synthesized by acid re-crystallization method and its thermoluminescence (TL) properties irradiated with thermal neutrons was studied. Structural and morphological characteristics have been studied using X-ray diffraction and SEM which mainly exhibits a orthorhombic structure with particle size of 200 to 250 mu m. Moreover, thermal neutron dosimetric characteristics of the microphosphor such as thermoluminescence glow curve, TL dose-response have been studied. This microphosphor powder represents a TL glow peak (T-max) centered at around 240 degrees C. The TL response of CaSO4:Dy microphosphor as a function of thermal neutron fluence is observed to be very linear upto the fluence of 52 x 10(11) n/cm(2) and further saturates. In addition, TL glow curves were deconvoluted by computerized glow curve deconvolution (CGCD) method and corresponding trapping parameters have been determined. It has been found that for every deconvoluted peak there is change in the order of kinetics. Overall, the experimental results show that the CaSO4:Dy microphosphor can have potential to be an effective thermal neutron dosimetry. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:226 / 230
页数:5
相关论文
共 50 条
  • [1] THERMAL-NEUTRON DOSIMETRY WITH CADMIUM COVERED CASO4=DY
    LAKSHMANAN, AR
    BHATT, RC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1977, 28 (07): : 665 - 666
  • [2] STUDIES ON THERMOLUMINESCENT CASO4 - DY FOR DOSIMETRY
    AYPAR, A
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1978, 29 (06): : 369 - 372
  • [3] MIXED FIELD DOSIMETRY WITH CASO4 - DY
    AYYANGAR, K
    CHANDRA, B
    LAKSHMANAN, AR
    PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (05): : 656 - 664
  • [4] Features of EPR dosimetry with CaSO4:Dy phosphor
    Bortolin, E
    Onori, S
    APPLIED RADIATION AND ISOTOPES, 2005, 62 (02) : 349 - 352
  • [5] NEUTRON DOSIMETRY USING ACTIVATION OF THERMOLUMINESCENT CASO4
    AZORIN, J
    GUTIERREZ, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (01): : 150 - 153
  • [6] High dose and phototransferred thermoluminescence in CaSO4, CaSO4:Dy, and CaSO4:Tm
    Lewandowski, AC
    Mathur, VK
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 213 - 216
  • [7] PHOTO-TL IN CASO4 - DY - HIGH EXPOSURE DOSIMETRY
    CALDAS, LVE
    MAYHUGH, MR
    HEALTH PHYSICS, 1976, 31 (05): : 451 - 452
  • [8] Preparation of CaSO4:Dy by precipitation method to gamma radiation dosimetry
    Rivera, T.
    Roman, J.
    Azorin, J.
    Sosa, R.
    Guzman, J.
    Serrano, A. K.
    Garcia, M.
    Alarcon, G.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 623 - 625
  • [9] Application of the CaSO4:Dy phototransfer phenomenon to high temperature dosimetry
    Goyet, D
    Lapraz, D
    Iacconi, P
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 317 - 320
  • [10] MIXED FIELD DOSIMETRY WITH CASO4 TM AND CASO4 TM - LI
    BEACH, JL
    HUANG, CY
    HEALTH PHYSICS, 1976, 31 (05): : 452 - 455