Removal of Fe (II) ions from drinking water using Electrocoagulation (EC) process: Parametric optimization and kinetic study

被引:41
|
作者
Das, Daisy [1 ]
Nandi, Barun Kumar [1 ]
机构
[1] Indian Sch Mines, Indian Inst Technol, Dept Fuel & Mineral Engn, Dhanbad 826004, Jharkhand, India
来源
关键词
Electrocoagulation; Drinking water; Fe (II) ion removal; TDS; Kinetic analysis; IRON REMOVAL; WASTE-WATER; GROUNDWATER; MANGANESE; ADSORPTION; FE(II); RIVER; COAGULATION; OXIDATION; FLUORIDE;
D O I
10.1016/j.jece.2019.103116
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Presence of Fe (II) ions in drinking water across different parts of India is a serious health concern in recent years. To reduce the Fe (II) ions in drinking water, researches are now being carried out using efficient and economical methods like adsorption, electrocoagulation etc. In the present work, experimental studies were carried out to optimize various operating parameters of electrocoagulation (EC) for efficient removal of iron (Fe (II) ions) from drinking water. Further, total dissolved solids, turbidity, conductivity, salinity, pH was accessed to verify the quality of treated water. From experimental results it was observed that, initial pH of 6.34, current density of 2 mA cm(-2) with inter-electrode distance of 1 cm, electrocoagulation time of 45 min, initial salt (NaCl) concentration of 0.33 g L-1, stirring speed of 400 RPM are the optimum operating parameters to produce drinkable water (Fe (II) ions < 0.30 mg L-1) from tap water having initial Fe (II) ions of 20 mg L-1. Kinetic analysis of EC process infers that Fe (II) ion removal follows the first-order kinetic model with respect to different operating parameters. The rate constant (k) increased from 0.0352 min(-1) to 0.1087 min(-1) when the current density was increased from 1 mA cm(-2) to 2.5 mA cm(-2), due to availability of higher amounts of aluminium ion flocs during EC. Experimental studies confirm that suspended flocs generated during electrocoagulation can be separated by centrifugal methods as well as microfiltration membrane to replace laboratory scale filter paper-based methods.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Defluoridization of drinking water by electrocoagulation (EC): process optimization and kinetic study
    Das, Daisy
    Nandi, Barun Kumar
    [J]. JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2019, 40 (08) : 1136 - 1146
  • [2] Simultaneous removal of fluoride and Fe (II) ions from drinking water by electrocoagulation
    Das, Daisy
    Nandi, Barun Kumar
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2020, 8 (01):
  • [3] Optimization of the process parameters for the removal of phosphate from drinking water by electrocoagulation
    Vasudevan, Subramanyan
    Lakshmi, Jothinathan
    Sozhan, Ganapathy
    [J]. DESALINATION AND WATER TREATMENT, 2009, 12 (1-3) : 407 - 414
  • [4] Removal of arsenic from drinking water by the electrocoagulation using Fe and Al electrodes
    Kobya, M.
    Gebologlu, U.
    Ulu, F.
    Oncel, S.
    Demirbas, E.
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (14) : 5060 - 5070
  • [5] Optimization of arsenic removal from drinking water by electrocoagulation batch process using response surface methodology
    Kobya, M.
    Demirbas, E.
    Gebologlu, U.
    Oncel, M. S.
    Yildirim, Y.
    [J]. DESALINATION AND WATER TREATMENT, 2013, 51 (34-36) : 6676 - 6687
  • [6] Optimization of the process parameters for the removal of boron from drinking water by electrocoagulation - a clean technology
    Vasudevan, Subramanyan
    Sheela, Sagayaraj Margrat
    Lakshmi, Jothinathan
    Sozhan, Ganapathy
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2010, 85 (07) : 926 - 933
  • [7] Factors influencing arsenic and nitrate removal from drinking water in a continuous flow electrocoagulation (EC) process
    Kumar, N. Sanjeev
    Goel, Sudha
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2010, 173 (1-3) : 528 - 533
  • [8] Removal of Hexavalent Chromium from Wastewater by Electrocoagulation (EC): Parametric Evaluation, Kinetic Study and Operating Cost
    Das, Daisy
    Nandi, Barun Kumar
    [J]. TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2020, 73 (08) : 2053 - 2060
  • [9] Removal of Hexavalent Chromium from Wastewater by Electrocoagulation (EC): Parametric Evaluation, Kinetic Study and Operating Cost
    Daisy Das
    Barun Kumar Nandi
    [J]. Transactions of the Indian Institute of Metals, 2020, 73 : 2053 - 2060
  • [10] Studies on the removal of phosphate from drinking water by electrocoagulation process
    Vasudevan, Subramanyan
    Sozhan, Ganapathy
    Ravichandran, Subbiah
    Jayaraj, Jeganathan
    Lakshmi, Jothinathan
    Sheela, Sagayaraj Margrat
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (06) : 2018 - 2023